Infrared assisted digestion used as a simple green sample preparation method for nutrient analysis of animal feed by microwave induced plasma atomic emission spectrometry
- Autores
- Cora Jofre, Florencia; Larregui, Daiana Natali; Murcia, Vanina Nerea; Pacheco, Pablo; Savio, Marianela
- Año de publicación
- 2021
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Based on green analytical chemistry principles it is important to evolve procedures that convert solid samples into solutions without using excessive reagent quantities, energy, temperature, and avoiding waste generation. To reach this aim, a simple infrared assisted digestion (IRAD) method for animal feed analysis was proposed. Infrared radiation (IR) with 2 mL of HNO3 and 2 mL of H2O2 were assessed, presenting low dissolved organic carbon (DOC) and residual acidity (RA) in the final digest, being fully compatible with microwave induced plasma atomic emission spectrometry (MIP OES). Calcium, Cd, Cu, Fe, K, Mg, Na, P, Sr and Zn were determined in reference materials and in animal feeds. Limits of quantification were between 2.52 and 284 mg kg−1 for Ca and P respectively. Recovery values ranged 80–120%, with relative standard deviations (RSD%) under 8%. The friendliness offered by the IRAD MIP OES method was evaluated by two green indexes. Concentrations in feedstuffs were compared with National Research Council (NRC) recommendations.
Con base en los principios de la química analítica verde, es importante desarrollar procedimientos que conviertan muestras sólidas en soluciones sin utilizar cantidades excesivas de reactivos, energía, temperatura y evitando la generación de residuos. Para alcanzar este objetivo, se propuso un método simple de digestión asistida por infrarrojos (IRAD) para el análisis de alimentos para animales. Se evaluó radiación infrarroja (IR) con 2 mL de HNO3 y 2 mL de H2O2, presentando bajo contenido de materia orgánica disuelta, carbono (DOC) y acidez residual (RA) en el digesto final, siendo totalmente compatible con microondas inducida espectrometría de emisión atómica de plasma (MIP OES). Se determinaron Calcio, Cd, Cu, Fe, K, Mg, Na, P, Sr y Zn en materiales de referencia y en alimentos para animales. Los límites de cuantificación estuvieron entre 2,52 y 284 mg kg− 1 para Ca y P respectivamente. Los valores de recuperación oscilaron entre 80 y 120 %, con desviaciones estándar relativas (RSD%) por debajo del 8 %. los La amabilidad ofrecida por el método IRAD MIP OES fue evaluada por dos índices verdes. Concentraciones en los alimentos se compararon con las recomendaciones del Consejo Nacional de Investigación (NRC).
EEA Anguil
Fil: Cora Jofre, Florencia. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Ciencias de la Tierra y Ambientales de La Pampa; Argentina
Fil: Larregui, Daiana Natali. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales; Argentina.
Fil: Murcia, Vanina. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria Anguil; Argentina
Fil: Pacheco, Pablo. Instituto de Química de San Luis; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Universidad Nacional de San Luis; Argentina
Fil: Savio, Marianela. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Ciencias de la Tierra y Ambientales de La Pampa; Argentina - Fuente
- Talanta 231 : 122376 (2021)
- Materia
-
Feeding
Swine
Spectrometry
Pork
Alimentación
Cerdo
Espectrometria
Carne de Cerdo
Porcinos - Nivel de accesibilidad
- acceso restringido
- Condiciones de uso
- Repositorio
- Institución
- Instituto Nacional de Tecnología Agropecuaria
- OAI Identificador
- oai:localhost:20.500.12123/12686
Ver los metadatos del registro completo
id |
INTADig_813ebaa36d9c5e8edf1a45b081cb8be3 |
---|---|
oai_identifier_str |
oai:localhost:20.500.12123/12686 |
network_acronym_str |
INTADig |
repository_id_str |
l |
network_name_str |
INTA Digital (INTA) |
spelling |
Infrared assisted digestion used as a simple green sample preparation method for nutrient analysis of animal feed by microwave induced plasma atomic emission spectrometryCora Jofre, FlorenciaLarregui, Daiana NataliMurcia, Vanina NereaPacheco, PabloSavio, MarianelaFeedingSwineSpectrometryPorkAlimentaciónCerdoEspectrometriaCarne de CerdoPorcinosBased on green analytical chemistry principles it is important to evolve procedures that convert solid samples into solutions without using excessive reagent quantities, energy, temperature, and avoiding waste generation. To reach this aim, a simple infrared assisted digestion (IRAD) method for animal feed analysis was proposed. Infrared radiation (IR) with 2 mL of HNO3 and 2 mL of H2O2 were assessed, presenting low dissolved organic carbon (DOC) and residual acidity (RA) in the final digest, being fully compatible with microwave induced plasma atomic emission spectrometry (MIP OES). Calcium, Cd, Cu, Fe, K, Mg, Na, P, Sr and Zn were determined in reference materials and in animal feeds. Limits of quantification were between 2.52 and 284 mg kg−1 for Ca and P respectively. Recovery values ranged 80–120%, with relative standard deviations (RSD%) under 8%. The friendliness offered by the IRAD MIP OES method was evaluated by two green indexes. Concentrations in feedstuffs were compared with National Research Council (NRC) recommendations.Con base en los principios de la química analítica verde, es importante desarrollar procedimientos que conviertan muestras sólidas en soluciones sin utilizar cantidades excesivas de reactivos, energía, temperatura y evitando la generación de residuos. Para alcanzar este objetivo, se propuso un método simple de digestión asistida por infrarrojos (IRAD) para el análisis de alimentos para animales. Se evaluó radiación infrarroja (IR) con 2 mL de HNO3 y 2 mL de H2O2, presentando bajo contenido de materia orgánica disuelta, carbono (DOC) y acidez residual (RA) en el digesto final, siendo totalmente compatible con microondas inducida espectrometría de emisión atómica de plasma (MIP OES). Se determinaron Calcio, Cd, Cu, Fe, K, Mg, Na, P, Sr y Zn en materiales de referencia y en alimentos para animales. Los límites de cuantificación estuvieron entre 2,52 y 284 mg kg− 1 para Ca y P respectivamente. Los valores de recuperación oscilaron entre 80 y 120 %, con desviaciones estándar relativas (RSD%) por debajo del 8 %. los La amabilidad ofrecida por el método IRAD MIP OES fue evaluada por dos índices verdes. Concentraciones en los alimentos se compararon con las recomendaciones del Consejo Nacional de Investigación (NRC).EEA AnguilFil: Cora Jofre, Florencia. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Ciencias de la Tierra y Ambientales de La Pampa; ArgentinaFil: Larregui, Daiana Natali. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales; Argentina.Fil: Murcia, Vanina. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria Anguil; ArgentinaFil: Pacheco, Pablo. Instituto de Química de San Luis; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Universidad Nacional de San Luis; ArgentinaFil: Savio, Marianela. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Ciencias de la Tierra y Ambientales de La Pampa; ArgentinaElsevier2022-08-25T13:00:53Z2022-08-25T13:00:53Z2021-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfhttp://hdl.handle.net/20.500.12123/12686https://www.sciencedirect.com/science/article/pii/S00399140210029760039-9140https://doi.org/10.1016/j.talanta.2021.122376Talanta 231 : 122376 (2021)reponame:INTA Digital (INTA)instname:Instituto Nacional de Tecnología Agropecuariaenginfo:eu-repo/semantics/restrictedAccess2025-09-04T09:49:32Zoai:localhost:20.500.12123/12686instacron:INTAInstitucionalhttp://repositorio.inta.gob.ar/Organismo científico-tecnológicoNo correspondehttp://repositorio.inta.gob.ar/oai/requesttripaldi.nicolas@inta.gob.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:l2025-09-04 09:49:32.783INTA Digital (INTA) - Instituto Nacional de Tecnología Agropecuariafalse |
dc.title.none.fl_str_mv |
Infrared assisted digestion used as a simple green sample preparation method for nutrient analysis of animal feed by microwave induced plasma atomic emission spectrometry |
title |
Infrared assisted digestion used as a simple green sample preparation method for nutrient analysis of animal feed by microwave induced plasma atomic emission spectrometry |
spellingShingle |
Infrared assisted digestion used as a simple green sample preparation method for nutrient analysis of animal feed by microwave induced plasma atomic emission spectrometry Cora Jofre, Florencia Feeding Swine Spectrometry Pork Alimentación Cerdo Espectrometria Carne de Cerdo Porcinos |
title_short |
Infrared assisted digestion used as a simple green sample preparation method for nutrient analysis of animal feed by microwave induced plasma atomic emission spectrometry |
title_full |
Infrared assisted digestion used as a simple green sample preparation method for nutrient analysis of animal feed by microwave induced plasma atomic emission spectrometry |
title_fullStr |
Infrared assisted digestion used as a simple green sample preparation method for nutrient analysis of animal feed by microwave induced plasma atomic emission spectrometry |
title_full_unstemmed |
Infrared assisted digestion used as a simple green sample preparation method for nutrient analysis of animal feed by microwave induced plasma atomic emission spectrometry |
title_sort |
Infrared assisted digestion used as a simple green sample preparation method for nutrient analysis of animal feed by microwave induced plasma atomic emission spectrometry |
dc.creator.none.fl_str_mv |
Cora Jofre, Florencia Larregui, Daiana Natali Murcia, Vanina Nerea Pacheco, Pablo Savio, Marianela |
author |
Cora Jofre, Florencia |
author_facet |
Cora Jofre, Florencia Larregui, Daiana Natali Murcia, Vanina Nerea Pacheco, Pablo Savio, Marianela |
author_role |
author |
author2 |
Larregui, Daiana Natali Murcia, Vanina Nerea Pacheco, Pablo Savio, Marianela |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
Feeding Swine Spectrometry Pork Alimentación Cerdo Espectrometria Carne de Cerdo Porcinos |
topic |
Feeding Swine Spectrometry Pork Alimentación Cerdo Espectrometria Carne de Cerdo Porcinos |
dc.description.none.fl_txt_mv |
Based on green analytical chemistry principles it is important to evolve procedures that convert solid samples into solutions without using excessive reagent quantities, energy, temperature, and avoiding waste generation. To reach this aim, a simple infrared assisted digestion (IRAD) method for animal feed analysis was proposed. Infrared radiation (IR) with 2 mL of HNO3 and 2 mL of H2O2 were assessed, presenting low dissolved organic carbon (DOC) and residual acidity (RA) in the final digest, being fully compatible with microwave induced plasma atomic emission spectrometry (MIP OES). Calcium, Cd, Cu, Fe, K, Mg, Na, P, Sr and Zn were determined in reference materials and in animal feeds. Limits of quantification were between 2.52 and 284 mg kg−1 for Ca and P respectively. Recovery values ranged 80–120%, with relative standard deviations (RSD%) under 8%. The friendliness offered by the IRAD MIP OES method was evaluated by two green indexes. Concentrations in feedstuffs were compared with National Research Council (NRC) recommendations. Con base en los principios de la química analítica verde, es importante desarrollar procedimientos que conviertan muestras sólidas en soluciones sin utilizar cantidades excesivas de reactivos, energía, temperatura y evitando la generación de residuos. Para alcanzar este objetivo, se propuso un método simple de digestión asistida por infrarrojos (IRAD) para el análisis de alimentos para animales. Se evaluó radiación infrarroja (IR) con 2 mL de HNO3 y 2 mL de H2O2, presentando bajo contenido de materia orgánica disuelta, carbono (DOC) y acidez residual (RA) en el digesto final, siendo totalmente compatible con microondas inducida espectrometría de emisión atómica de plasma (MIP OES). Se determinaron Calcio, Cd, Cu, Fe, K, Mg, Na, P, Sr y Zn en materiales de referencia y en alimentos para animales. Los límites de cuantificación estuvieron entre 2,52 y 284 mg kg− 1 para Ca y P respectivamente. Los valores de recuperación oscilaron entre 80 y 120 %, con desviaciones estándar relativas (RSD%) por debajo del 8 %. los La amabilidad ofrecida por el método IRAD MIP OES fue evaluada por dos índices verdes. Concentraciones en los alimentos se compararon con las recomendaciones del Consejo Nacional de Investigación (NRC). EEA Anguil Fil: Cora Jofre, Florencia. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Ciencias de la Tierra y Ambientales de La Pampa; Argentina Fil: Larregui, Daiana Natali. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales; Argentina. Fil: Murcia, Vanina. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria Anguil; Argentina Fil: Pacheco, Pablo. Instituto de Química de San Luis; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Universidad Nacional de San Luis; Argentina Fil: Savio, Marianela. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Ciencias de la Tierra y Ambientales de La Pampa; Argentina |
description |
Based on green analytical chemistry principles it is important to evolve procedures that convert solid samples into solutions without using excessive reagent quantities, energy, temperature, and avoiding waste generation. To reach this aim, a simple infrared assisted digestion (IRAD) method for animal feed analysis was proposed. Infrared radiation (IR) with 2 mL of HNO3 and 2 mL of H2O2 were assessed, presenting low dissolved organic carbon (DOC) and residual acidity (RA) in the final digest, being fully compatible with microwave induced plasma atomic emission spectrometry (MIP OES). Calcium, Cd, Cu, Fe, K, Mg, Na, P, Sr and Zn were determined in reference materials and in animal feeds. Limits of quantification were between 2.52 and 284 mg kg−1 for Ca and P respectively. Recovery values ranged 80–120%, with relative standard deviations (RSD%) under 8%. The friendliness offered by the IRAD MIP OES method was evaluated by two green indexes. Concentrations in feedstuffs were compared with National Research Council (NRC) recommendations. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-08-01 2022-08-25T13:00:53Z 2022-08-25T13:00:53Z |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/20.500.12123/12686 https://www.sciencedirect.com/science/article/pii/S0039914021002976 0039-9140 https://doi.org/10.1016/j.talanta.2021.122376 |
url |
http://hdl.handle.net/20.500.12123/12686 https://www.sciencedirect.com/science/article/pii/S0039914021002976 https://doi.org/10.1016/j.talanta.2021.122376 |
identifier_str_mv |
0039-9140 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/restrictedAccess |
eu_rights_str_mv |
restrictedAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
Talanta 231 : 122376 (2021) reponame:INTA Digital (INTA) instname:Instituto Nacional de Tecnología Agropecuaria |
reponame_str |
INTA Digital (INTA) |
collection |
INTA Digital (INTA) |
instname_str |
Instituto Nacional de Tecnología Agropecuaria |
repository.name.fl_str_mv |
INTA Digital (INTA) - Instituto Nacional de Tecnología Agropecuaria |
repository.mail.fl_str_mv |
tripaldi.nicolas@inta.gob.ar |
_version_ |
1842341399827054592 |
score |
12.623145 |