- A new methodology involving four-way multivariate calibration with a balanced number of data points in all modes is presented. The method is based on fluorescence excitation-emission matrices modulated by a double pH gradient obtained in a flow injection system. This data array was employed for the quantitation of ciprofloxacin, ofloxacin and norfloxacin in unprocessed urine samples. Due to the presence of potential interfering compounds with overlapping profiles in the analyzed samples, it is required to achieve the second-order advantage. The four-way arrays obtained were processed by parallel factor analysis (PARAFAC), attaining satisfactory results with relative errors of prediction (REP%) between 3% and 7.5% in the analyzed samples for all analytes. The average limit of detection (mg L− 1) was 0.035 for norfloxacin and ofloxacin and 0.028 for ciprofloxacin.
Fil: Pagani, Ariana Paula. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Química Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario; Argentina
Fil: Ibañez, Gabriela Alejandra. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Química Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario; Argentina - Materia
-
Excitation-Emission Fluorescence Matrices
Fluoroquinolones
Parafac
Ph-Gradient
Third-Order Multivariate Analysis - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/63890
Ver los metadatos del registro completo
id |
CONICETDig_3efb0c6a5b3048dbc13b30c9fe24099e |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/63890 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlappingPagani, Ariana PaulaIbañez, Gabriela AlejandraExcitation-Emission Fluorescence MatricesFluoroquinolonesParafacPh-GradientThird-Order Multivariate Analysishttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1A new methodology involving four-way multivariate calibration with a balanced number of data points in all modes is presented. The method is based on fluorescence excitation-emission matrices modulated by a double pH gradient obtained in a flow injection system. This data array was employed for the quantitation of ciprofloxacin, ofloxacin and norfloxacin in unprocessed urine samples. Due to the presence of potential interfering compounds with overlapping profiles in the analyzed samples, it is required to achieve the second-order advantage. The four-way arrays obtained were processed by parallel factor analysis (PARAFAC), attaining satisfactory results with relative errors of prediction (REP%) between 3% and 7.5% in the analyzed samples for all analytes. The average limit of detection (mg L− 1) was 0.035 for norfloxacin and ofloxacin and 0.028 for ciprofloxacin.Fil: Pagani, Ariana Paula. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Química Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario; ArgentinaFil: Ibañez, Gabriela Alejandra. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Química Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario; ArgentinaElsevier Science2017-05info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/63890Pagani, Ariana Paula; Ibañez, Gabriela Alejandra; Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping; Elsevier Science; Microchemical Journal; 132; 5-2017; 211-2180026-265XCONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.microc.2017.01.028info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0026265X1630371Xinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T09:37:04Zoai:ri.conicet.gov.ar:11336/63890instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 09:37:04.705CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping |
title |
Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping |
spellingShingle |
Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping Pagani, Ariana Paula Excitation-Emission Fluorescence Matrices Fluoroquinolones Parafac Ph-Gradient Third-Order Multivariate Analysis |
title_short |
Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping |
title_full |
Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping |
title_fullStr |
Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping |
title_full_unstemmed |
Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping |
title_sort |
Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping |
dc.creator.none.fl_str_mv |
Pagani, Ariana Paula Ibañez, Gabriela Alejandra |
author |
Pagani, Ariana Paula |
author_facet |
Pagani, Ariana Paula Ibañez, Gabriela Alejandra |
author_role |
author |
author2 |
Ibañez, Gabriela Alejandra |
author2_role |
author |
dc.subject.none.fl_str_mv |
Excitation-Emission Fluorescence Matrices Fluoroquinolones Parafac Ph-Gradient Third-Order Multivariate Analysis |
topic |
Excitation-Emission Fluorescence Matrices Fluoroquinolones Parafac Ph-Gradient Third-Order Multivariate Analysis |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
A new methodology involving four-way multivariate calibration with a balanced number of data points in all modes is presented. The method is based on fluorescence excitation-emission matrices modulated by a double pH gradient obtained in a flow injection system. This data array was employed for the quantitation of ciprofloxacin, ofloxacin and norfloxacin in unprocessed urine samples. Due to the presence of potential interfering compounds with overlapping profiles in the analyzed samples, it is required to achieve the second-order advantage. The four-way arrays obtained were processed by parallel factor analysis (PARAFAC), attaining satisfactory results with relative errors of prediction (REP%) between 3% and 7.5% in the analyzed samples for all analytes. The average limit of detection (mg L− 1) was 0.035 for norfloxacin and ofloxacin and 0.028 for ciprofloxacin. Fil: Pagani, Ariana Paula. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Química Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario; Argentina Fil: Ibañez, Gabriela Alejandra. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Química Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario; Argentina |
description |
A new methodology involving four-way multivariate calibration with a balanced number of data points in all modes is presented. The method is based on fluorescence excitation-emission matrices modulated by a double pH gradient obtained in a flow injection system. This data array was employed for the quantitation of ciprofloxacin, ofloxacin and norfloxacin in unprocessed urine samples. Due to the presence of potential interfering compounds with overlapping profiles in the analyzed samples, it is required to achieve the second-order advantage. The four-way arrays obtained were processed by parallel factor analysis (PARAFAC), attaining satisfactory results with relative errors of prediction (REP%) between 3% and 7.5% in the analyzed samples for all analytes. The average limit of detection (mg L− 1) was 0.035 for norfloxacin and ofloxacin and 0.028 for ciprofloxacin. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-05 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/63890 Pagani, Ariana Paula; Ibañez, Gabriela Alejandra; Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping; Elsevier Science; Microchemical Journal; 132; 5-2017; 211-218 0026-265X CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/63890 |
identifier_str_mv |
Pagani, Ariana Paula; Ibañez, Gabriela Alejandra; Four-way calibration applied to the processing of pH-modulated fluorescence excitation-emission matrices. Analysis of fluoroquinolones in the presence of significant spectral overlapping; Elsevier Science; Microchemical Journal; 132; 5-2017; 211-218 0026-265X CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.microc.2017.01.028 info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0026265X1630371X |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier Science |
publisher.none.fl_str_mv |
Elsevier Science |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844613166428848128 |
score |
13.070432 |