Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperatu...

Autores
Goicoechea, Hector Casimiro; Calimag Williams, Korina; Campiglia, Andres D.
Año de publicación
2012
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Multi-way partial least-squares (N-PLS) is combined to the residual bi-linearization procedure (RBL) for the direct analysis of metabolites of polycyclic aromatic hydrocarbons in urine samples. Metabolite analysis is carried out via a two-step experimental procedure based on solid-phase extraction and room temperature fluorescence spectroscopy. Excitation-emission matrices are recorded from octadecyl (C18) membranes that serve as solid substrates for sample extraction and spectroscopic measurements. Excellent metabolite recoveries were obtained in all cases, which varied from 96.2±1.35% (9-hydroxyphenanthrene) to 99.7±0.49% (3-hydroxybenzo[a]pyrene). Background correction of extraction membranes is carried out with a new alternating least-squares (ALS) procedure adapted to second order data. The performance of N-PLS/RBL is compared to the well-established multivariate curve resolution-alternating least-squares (MCR-ALS) algorithm. Both algorithms provided similar analytical figures of merit, including their ability to handle unknown interference in urine samples. With only 10mL of sample, the limits of detection varied between 0.06-0.08ngmL -1 (1-hydroxypyrene) and 0.016-0.018ngmL -1 (2-hydroxyfluorene). When compared to previously reported univariate calibration data, the limits of detection via N-PLS/RBL and MCR-ALS are approximately one order of magnitude higher. This was somehow expected due to the effect of unexpected components in multivariate figures of merit, i.e. a more realistic approach to the analysis of metabolites in human urine samples. © 2011 Elsevier B.V..
Fil: Goicoechea, Hector Casimiro. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. University of Central Florida; Estados Unidos
Fil: Calimag Williams, Korina. University of Central Florida; Estados Unidos
Fil: Campiglia, Andres D.. University of Central Florida; Estados Unidos
Materia
Excitation-Emission Matrices
Room-Temperature Fluorescence
Second-Order Multivariate Calibration
Solid-Phase Extraction
Urine Analysis
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/60100

id CONICETDig_e4e577ccf1ac7f0f4e33e634573dcd52
oai_identifier_str oai:ri.conicet.gov.ar:11336/60100
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matricesGoicoechea, Hector CasimiroCalimag Williams, KorinaCampiglia, Andres D.Excitation-Emission MatricesRoom-Temperature FluorescenceSecond-Order Multivariate CalibrationSolid-Phase ExtractionUrine Analysishttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1Multi-way partial least-squares (N-PLS) is combined to the residual bi-linearization procedure (RBL) for the direct analysis of metabolites of polycyclic aromatic hydrocarbons in urine samples. Metabolite analysis is carried out via a two-step experimental procedure based on solid-phase extraction and room temperature fluorescence spectroscopy. Excitation-emission matrices are recorded from octadecyl (C18) membranes that serve as solid substrates for sample extraction and spectroscopic measurements. Excellent metabolite recoveries were obtained in all cases, which varied from 96.2±1.35% (9-hydroxyphenanthrene) to 99.7±0.49% (3-hydroxybenzo[a]pyrene). Background correction of extraction membranes is carried out with a new alternating least-squares (ALS) procedure adapted to second order data. The performance of N-PLS/RBL is compared to the well-established multivariate curve resolution-alternating least-squares (MCR-ALS) algorithm. Both algorithms provided similar analytical figures of merit, including their ability to handle unknown interference in urine samples. With only 10mL of sample, the limits of detection varied between 0.06-0.08ngmL -1 (1-hydroxypyrene) and 0.016-0.018ngmL -1 (2-hydroxyfluorene). When compared to previously reported univariate calibration data, the limits of detection via N-PLS/RBL and MCR-ALS are approximately one order of magnitude higher. This was somehow expected due to the effect of unexpected components in multivariate figures of merit, i.e. a more realistic approach to the analysis of metabolites in human urine samples. © 2011 Elsevier B.V..Fil: Goicoechea, Hector Casimiro. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. University of Central Florida; Estados UnidosFil: Calimag Williams, Korina. University of Central Florida; Estados UnidosFil: Campiglia, Andres D.. University of Central Florida; Estados UnidosElsevier Science2012-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/60100Goicoechea, Hector Casimiro; Calimag Williams, Korina; Campiglia, Andres D.; Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices; Elsevier Science; Analytica Chimica Acta; 717; 3-2012; 100-1090003-2670CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.aca.2011.12.031info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0003267011016965info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:49:15Zoai:ri.conicet.gov.ar:11336/60100instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:49:15.544CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices
title Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices
spellingShingle Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices
Goicoechea, Hector Casimiro
Excitation-Emission Matrices
Room-Temperature Fluorescence
Second-Order Multivariate Calibration
Solid-Phase Extraction
Urine Analysis
title_short Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices
title_full Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices
title_fullStr Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices
title_full_unstemmed Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices
title_sort Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices
dc.creator.none.fl_str_mv Goicoechea, Hector Casimiro
Calimag Williams, Korina
Campiglia, Andres D.
author Goicoechea, Hector Casimiro
author_facet Goicoechea, Hector Casimiro
Calimag Williams, Korina
Campiglia, Andres D.
author_role author
author2 Calimag Williams, Korina
Campiglia, Andres D.
author2_role author
author
dc.subject.none.fl_str_mv Excitation-Emission Matrices
Room-Temperature Fluorescence
Second-Order Multivariate Calibration
Solid-Phase Extraction
Urine Analysis
topic Excitation-Emission Matrices
Room-Temperature Fluorescence
Second-Order Multivariate Calibration
Solid-Phase Extraction
Urine Analysis
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.4
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv Multi-way partial least-squares (N-PLS) is combined to the residual bi-linearization procedure (RBL) for the direct analysis of metabolites of polycyclic aromatic hydrocarbons in urine samples. Metabolite analysis is carried out via a two-step experimental procedure based on solid-phase extraction and room temperature fluorescence spectroscopy. Excitation-emission matrices are recorded from octadecyl (C18) membranes that serve as solid substrates for sample extraction and spectroscopic measurements. Excellent metabolite recoveries were obtained in all cases, which varied from 96.2±1.35% (9-hydroxyphenanthrene) to 99.7±0.49% (3-hydroxybenzo[a]pyrene). Background correction of extraction membranes is carried out with a new alternating least-squares (ALS) procedure adapted to second order data. The performance of N-PLS/RBL is compared to the well-established multivariate curve resolution-alternating least-squares (MCR-ALS) algorithm. Both algorithms provided similar analytical figures of merit, including their ability to handle unknown interference in urine samples. With only 10mL of sample, the limits of detection varied between 0.06-0.08ngmL -1 (1-hydroxypyrene) and 0.016-0.018ngmL -1 (2-hydroxyfluorene). When compared to previously reported univariate calibration data, the limits of detection via N-PLS/RBL and MCR-ALS are approximately one order of magnitude higher. This was somehow expected due to the effect of unexpected components in multivariate figures of merit, i.e. a more realistic approach to the analysis of metabolites in human urine samples. © 2011 Elsevier B.V..
Fil: Goicoechea, Hector Casimiro. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. University of Central Florida; Estados Unidos
Fil: Calimag Williams, Korina. University of Central Florida; Estados Unidos
Fil: Campiglia, Andres D.. University of Central Florida; Estados Unidos
description Multi-way partial least-squares (N-PLS) is combined to the residual bi-linearization procedure (RBL) for the direct analysis of metabolites of polycyclic aromatic hydrocarbons in urine samples. Metabolite analysis is carried out via a two-step experimental procedure based on solid-phase extraction and room temperature fluorescence spectroscopy. Excitation-emission matrices are recorded from octadecyl (C18) membranes that serve as solid substrates for sample extraction and spectroscopic measurements. Excellent metabolite recoveries were obtained in all cases, which varied from 96.2±1.35% (9-hydroxyphenanthrene) to 99.7±0.49% (3-hydroxybenzo[a]pyrene). Background correction of extraction membranes is carried out with a new alternating least-squares (ALS) procedure adapted to second order data. The performance of N-PLS/RBL is compared to the well-established multivariate curve resolution-alternating least-squares (MCR-ALS) algorithm. Both algorithms provided similar analytical figures of merit, including their ability to handle unknown interference in urine samples. With only 10mL of sample, the limits of detection varied between 0.06-0.08ngmL -1 (1-hydroxypyrene) and 0.016-0.018ngmL -1 (2-hydroxyfluorene). When compared to previously reported univariate calibration data, the limits of detection via N-PLS/RBL and MCR-ALS are approximately one order of magnitude higher. This was somehow expected due to the effect of unexpected components in multivariate figures of merit, i.e. a more realistic approach to the analysis of metabolites in human urine samples. © 2011 Elsevier B.V..
publishDate 2012
dc.date.none.fl_str_mv 2012-03
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/60100
Goicoechea, Hector Casimiro; Calimag Williams, Korina; Campiglia, Andres D.; Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices; Elsevier Science; Analytica Chimica Acta; 717; 3-2012; 100-109
0003-2670
CONICET Digital
CONICET
url http://hdl.handle.net/11336/60100
identifier_str_mv Goicoechea, Hector Casimiro; Calimag Williams, Korina; Campiglia, Andres D.; Multi-way partial least-squares and residual bi-linearization for the direct determination of monohydroxy-polycyclic aromatic hydrocarbons on octadecyl membranes via room-temperature fluorescence excitation emission matrices; Elsevier Science; Analytica Chimica Acta; 717; 3-2012; 100-109
0003-2670
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/10.1016/j.aca.2011.12.031
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0003267011016965
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier Science
publisher.none.fl_str_mv Elsevier Science
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1842268962634596352
score 13.13397