Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease
- Autores
- Carrascosa, Patricia M.; Deviggiano, Alejandro; Capunay, Carlos; Campisi, Roxana; López de Munain, Marina; Vallejos, Javier; Tajer, Carlos; Rodriguez Granillo, Gaston Alfredo
- Año de publicación
- 2015
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Purpose: We sought to explore the diagnostic performance of dual energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD). Materials and methods: Consecutive patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT) constituted the study population and were scanned using a DECT scanner equipped with gemstone detectors for spectral imaging, and a SPECT. The same pharmacological stress was used for both scans. Results: Twenty-five patients were prospectively included in the study protocol. The mean age was 63.4 ± 10.6 years. The total mean effective radiation dose was 7.5 ± 1.2 mSv with DECT and 8.2 ± 1.7 mSv with SPECT (p = 0.007). A total of 425 left ventricular segments were evaluated by DECT, showing a reliable accuracy for the detection of reversible perfusion defects [area under ROC curve (AUC) 0.84 (0.80-0.87)]. Furthermore, adding stress myocardial perfusion provided a significant incremental value over anatomical evaluation alone by computed tomography coronary angiography [AUC 0.70 (0.65-0.74), p = 0.003]. Conclusions: In this pilot investigation, stress myocardial perfusion by DECT demonstrated a significant incremental value over anatomical evaluation alone by CTCA for the detection of reversible perfusion defects.
Fil: Carrascosa, Patricia M.. Diagnóstico Maipú; Argentina
Fil: Deviggiano, Alejandro. Diagnóstico Maipú; Argentina
Fil: Capunay, Carlos. Diagnóstico Maipú; Argentina
Fil: Campisi, Roxana. Diagnóstico Maipú; Argentina
Fil: López de Munain, Marina. Diagnóstico Maipú; Argentina
Fil: Vallejos, Javier. Diagnóstico Maipú; Argentina
Fil: Tajer, Carlos. Diagnóstico Maipú; Argentina
Fil: Rodriguez Granillo, Gaston Alfredo. Diagnóstico Maipú; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina - Materia
-
Dipyridamole
Imaging
Ischemia
Spect - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/38521
Ver los metadatos del registro completo
id |
CONICETDig_1452dbbc7a8d3d68a9bffa7a64a6923b |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/38521 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery diseaseCarrascosa, Patricia M.Deviggiano, AlejandroCapunay, CarlosCampisi, RoxanaLópez de Munain, MarinaVallejos, JavierTajer, CarlosRodriguez Granillo, Gaston AlfredoDipyridamoleImagingIschemiaSpecthttps://purl.org/becyt/ford/3.2https://purl.org/becyt/ford/3Purpose: We sought to explore the diagnostic performance of dual energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD). Materials and methods: Consecutive patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT) constituted the study population and were scanned using a DECT scanner equipped with gemstone detectors for spectral imaging, and a SPECT. The same pharmacological stress was used for both scans. Results: Twenty-five patients were prospectively included in the study protocol. The mean age was 63.4 ± 10.6 years. The total mean effective radiation dose was 7.5 ± 1.2 mSv with DECT and 8.2 ± 1.7 mSv with SPECT (p = 0.007). A total of 425 left ventricular segments were evaluated by DECT, showing a reliable accuracy for the detection of reversible perfusion defects [area under ROC curve (AUC) 0.84 (0.80-0.87)]. Furthermore, adding stress myocardial perfusion provided a significant incremental value over anatomical evaluation alone by computed tomography coronary angiography [AUC 0.70 (0.65-0.74), p = 0.003]. Conclusions: In this pilot investigation, stress myocardial perfusion by DECT demonstrated a significant incremental value over anatomical evaluation alone by CTCA for the detection of reversible perfusion defects.Fil: Carrascosa, Patricia M.. Diagnóstico Maipú; ArgentinaFil: Deviggiano, Alejandro. Diagnóstico Maipú; ArgentinaFil: Capunay, Carlos. Diagnóstico Maipú; ArgentinaFil: Campisi, Roxana. Diagnóstico Maipú; ArgentinaFil: López de Munain, Marina. Diagnóstico Maipú; ArgentinaFil: Vallejos, Javier. Diagnóstico Maipú; ArgentinaFil: Tajer, Carlos. Diagnóstico Maipú; ArgentinaFil: Rodriguez Granillo, Gaston Alfredo. Diagnóstico Maipú; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaElsevier Ireland2015-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/38521Carrascosa, Patricia M.; Deviggiano, Alejandro; Capunay, Carlos; Campisi, Roxana; López de Munain, Marina; et al.; Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease; Elsevier Ireland; European Journal Of Radiology; 84; 4; 4-2015; 637-6420720-048XCONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.ejrad.2014.12.013info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0720048X15000029info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T09:45:24Zoai:ri.conicet.gov.ar:11336/38521instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 09:45:24.254CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease |
title |
Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease |
spellingShingle |
Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease Carrascosa, Patricia M. Dipyridamole Imaging Ischemia Spect |
title_short |
Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease |
title_full |
Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease |
title_fullStr |
Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease |
title_full_unstemmed |
Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease |
title_sort |
Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease |
dc.creator.none.fl_str_mv |
Carrascosa, Patricia M. Deviggiano, Alejandro Capunay, Carlos Campisi, Roxana López de Munain, Marina Vallejos, Javier Tajer, Carlos Rodriguez Granillo, Gaston Alfredo |
author |
Carrascosa, Patricia M. |
author_facet |
Carrascosa, Patricia M. Deviggiano, Alejandro Capunay, Carlos Campisi, Roxana López de Munain, Marina Vallejos, Javier Tajer, Carlos Rodriguez Granillo, Gaston Alfredo |
author_role |
author |
author2 |
Deviggiano, Alejandro Capunay, Carlos Campisi, Roxana López de Munain, Marina Vallejos, Javier Tajer, Carlos Rodriguez Granillo, Gaston Alfredo |
author2_role |
author author author author author author author |
dc.subject.none.fl_str_mv |
Dipyridamole Imaging Ischemia Spect |
topic |
Dipyridamole Imaging Ischemia Spect |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/3.2 https://purl.org/becyt/ford/3 |
dc.description.none.fl_txt_mv |
Purpose: We sought to explore the diagnostic performance of dual energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD). Materials and methods: Consecutive patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT) constituted the study population and were scanned using a DECT scanner equipped with gemstone detectors for spectral imaging, and a SPECT. The same pharmacological stress was used for both scans. Results: Twenty-five patients were prospectively included in the study protocol. The mean age was 63.4 ± 10.6 years. The total mean effective radiation dose was 7.5 ± 1.2 mSv with DECT and 8.2 ± 1.7 mSv with SPECT (p = 0.007). A total of 425 left ventricular segments were evaluated by DECT, showing a reliable accuracy for the detection of reversible perfusion defects [area under ROC curve (AUC) 0.84 (0.80-0.87)]. Furthermore, adding stress myocardial perfusion provided a significant incremental value over anatomical evaluation alone by computed tomography coronary angiography [AUC 0.70 (0.65-0.74), p = 0.003]. Conclusions: In this pilot investigation, stress myocardial perfusion by DECT demonstrated a significant incremental value over anatomical evaluation alone by CTCA for the detection of reversible perfusion defects. Fil: Carrascosa, Patricia M.. Diagnóstico Maipú; Argentina Fil: Deviggiano, Alejandro. Diagnóstico Maipú; Argentina Fil: Capunay, Carlos. Diagnóstico Maipú; Argentina Fil: Campisi, Roxana. Diagnóstico Maipú; Argentina Fil: López de Munain, Marina. Diagnóstico Maipú; Argentina Fil: Vallejos, Javier. Diagnóstico Maipú; Argentina Fil: Tajer, Carlos. Diagnóstico Maipú; Argentina Fil: Rodriguez Granillo, Gaston Alfredo. Diagnóstico Maipú; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina |
description |
Purpose: We sought to explore the diagnostic performance of dual energy computed tomography (DECT) for the evaluation of myocardial perfusion in patients with intermediate to high likelihood of coronary artery disease (CAD). Materials and methods: Consecutive patients with known or suspected CAD referred for myocardial perfusion imaging by single-photon emission computed tomography (SPECT) constituted the study population and were scanned using a DECT scanner equipped with gemstone detectors for spectral imaging, and a SPECT. The same pharmacological stress was used for both scans. Results: Twenty-five patients were prospectively included in the study protocol. The mean age was 63.4 ± 10.6 years. The total mean effective radiation dose was 7.5 ± 1.2 mSv with DECT and 8.2 ± 1.7 mSv with SPECT (p = 0.007). A total of 425 left ventricular segments were evaluated by DECT, showing a reliable accuracy for the detection of reversible perfusion defects [area under ROC curve (AUC) 0.84 (0.80-0.87)]. Furthermore, adding stress myocardial perfusion provided a significant incremental value over anatomical evaluation alone by computed tomography coronary angiography [AUC 0.70 (0.65-0.74), p = 0.003]. Conclusions: In this pilot investigation, stress myocardial perfusion by DECT demonstrated a significant incremental value over anatomical evaluation alone by CTCA for the detection of reversible perfusion defects. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-04 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/38521 Carrascosa, Patricia M.; Deviggiano, Alejandro; Capunay, Carlos; Campisi, Roxana; López de Munain, Marina; et al.; Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease; Elsevier Ireland; European Journal Of Radiology; 84; 4; 4-2015; 637-642 0720-048X CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/38521 |
identifier_str_mv |
Carrascosa, Patricia M.; Deviggiano, Alejandro; Capunay, Carlos; Campisi, Roxana; López de Munain, Marina; et al.; Incremental value of myocardial perfusion over coronary angiography by spectral computed tomography in patients with intermediate to high likelihood of coronary artery disease; Elsevier Ireland; European Journal Of Radiology; 84; 4; 4-2015; 637-642 0720-048X CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.ejrad.2014.12.013 info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0720048X15000029 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier Ireland |
publisher.none.fl_str_mv |
Elsevier Ireland |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844613424052436992 |
score |
13.070432 |