Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease
- Autores
- Carrascosa, Patricia; Deviggiano, Alejandro; Leipsic, Jonathon A.; Capunay, Carlos; De Zan, Macarena C.; Goldsmit, Alejandro; Rodriguez Granillo, Gaston Alfredo
- Año de publicación
- 2015
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- We explored whether intracycle motion correction algorithms (MCAs) might be applicable to dual energy computed tomography coronary angiography in patients with intermediate to high likelihood of coronary artery disease. MCA reconstructions were associated with higher interpretability rates (96.7% vs 87.9%, P < .001), image quality scores (4.12±0.9 vs. 3.76±1.0; P < .0001), and diagnostic performance [area under the curve of 0.95 (95% confidence interval [CI] 0.92-0.97) vs 0.89 (95% CI 0.86-0.92); P < .0001] compared to conventional reconstructions. In conclusion, application of intracycle MCA reconstructions to dual energy computed tomography acquisitions was feasible and resulted in significantly higher image quality scores, interpretability, and diagnostic performance.
Fil: Carrascosa, Patricia. Diagnóstico Maipú; Argentina
Fil: Deviggiano, Alejandro. Diagnóstico Maipú; Argentina
Fil: Leipsic, Jonathon A.. St. Paul's Hospital; Canadá
Fil: Capunay, Carlos. Diagnóstico Maipú; Argentina
Fil: De Zan, Macarena C.. Diagnóstico Maipú; Argentina
Fil: Goldsmit, Alejandro. Sanatorio Güemes; Argentina
Fil: Rodriguez Granillo, Gaston Alfredo. Diagnóstico Maipú; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Cardiológicas. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Investigaciones Cardiológicas; Argentina - Materia
-
Beta Blockers
Imaging
Interpretability
Multidetector
Spectral - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/39073
Ver los metadatos del registro completo
id |
CONICETDig_f517dd18213003fb9837f7abdfb4b06c |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/39073 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery diseaseCarrascosa, PatriciaDeviggiano, AlejandroLeipsic, Jonathon A.Capunay, CarlosDe Zan, Macarena C.Goldsmit, AlejandroRodriguez Granillo, Gaston AlfredoBeta BlockersImagingInterpretabilityMultidetectorSpectralhttps://purl.org/becyt/ford/3.2https://purl.org/becyt/ford/3We explored whether intracycle motion correction algorithms (MCAs) might be applicable to dual energy computed tomography coronary angiography in patients with intermediate to high likelihood of coronary artery disease. MCA reconstructions were associated with higher interpretability rates (96.7% vs 87.9%, P < .001), image quality scores (4.12±0.9 vs. 3.76±1.0; P < .0001), and diagnostic performance [area under the curve of 0.95 (95% confidence interval [CI] 0.92-0.97) vs 0.89 (95% CI 0.86-0.92); P < .0001] compared to conventional reconstructions. In conclusion, application of intracycle MCA reconstructions to dual energy computed tomography acquisitions was feasible and resulted in significantly higher image quality scores, interpretability, and diagnostic performance.Fil: Carrascosa, Patricia. Diagnóstico Maipú; ArgentinaFil: Deviggiano, Alejandro. Diagnóstico Maipú; ArgentinaFil: Leipsic, Jonathon A.. St. Paul's Hospital; CanadáFil: Capunay, Carlos. Diagnóstico Maipú; ArgentinaFil: De Zan, Macarena C.. Diagnóstico Maipú; ArgentinaFil: Goldsmit, Alejandro. Sanatorio Güemes; ArgentinaFil: Rodriguez Granillo, Gaston Alfredo. Diagnóstico Maipú; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Cardiológicas. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Investigaciones Cardiológicas; ArgentinaElsevier Science Inc2015-11info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/vnd.openxmlformats-officedocument.wordprocessingml.documentapplication/pdfhttp://hdl.handle.net/11336/39073Carrascosa, Patricia; Deviggiano, Alejandro; Leipsic, Jonathon A.; Capunay, Carlos; De Zan, Macarena C.; et al.; Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease; Elsevier Science Inc; Clinical Imaging; 39; 6; 11-2015; 1000-10050899-7071CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0899707115001886info:eu-repo/semantics/altIdentifier/doi/10.1016/j.clinimag.2015.07.023info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:55:06Zoai:ri.conicet.gov.ar:11336/39073instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:55:07.04CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease |
title |
Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease |
spellingShingle |
Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease Carrascosa, Patricia Beta Blockers Imaging Interpretability Multidetector Spectral |
title_short |
Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease |
title_full |
Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease |
title_fullStr |
Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease |
title_full_unstemmed |
Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease |
title_sort |
Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease |
dc.creator.none.fl_str_mv |
Carrascosa, Patricia Deviggiano, Alejandro Leipsic, Jonathon A. Capunay, Carlos De Zan, Macarena C. Goldsmit, Alejandro Rodriguez Granillo, Gaston Alfredo |
author |
Carrascosa, Patricia |
author_facet |
Carrascosa, Patricia Deviggiano, Alejandro Leipsic, Jonathon A. Capunay, Carlos De Zan, Macarena C. Goldsmit, Alejandro Rodriguez Granillo, Gaston Alfredo |
author_role |
author |
author2 |
Deviggiano, Alejandro Leipsic, Jonathon A. Capunay, Carlos De Zan, Macarena C. Goldsmit, Alejandro Rodriguez Granillo, Gaston Alfredo |
author2_role |
author author author author author author |
dc.subject.none.fl_str_mv |
Beta Blockers Imaging Interpretability Multidetector Spectral |
topic |
Beta Blockers Imaging Interpretability Multidetector Spectral |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/3.2 https://purl.org/becyt/ford/3 |
dc.description.none.fl_txt_mv |
We explored whether intracycle motion correction algorithms (MCAs) might be applicable to dual energy computed tomography coronary angiography in patients with intermediate to high likelihood of coronary artery disease. MCA reconstructions were associated with higher interpretability rates (96.7% vs 87.9%, P < .001), image quality scores (4.12±0.9 vs. 3.76±1.0; P < .0001), and diagnostic performance [area under the curve of 0.95 (95% confidence interval [CI] 0.92-0.97) vs 0.89 (95% CI 0.86-0.92); P < .0001] compared to conventional reconstructions. In conclusion, application of intracycle MCA reconstructions to dual energy computed tomography acquisitions was feasible and resulted in significantly higher image quality scores, interpretability, and diagnostic performance. Fil: Carrascosa, Patricia. Diagnóstico Maipú; Argentina Fil: Deviggiano, Alejandro. Diagnóstico Maipú; Argentina Fil: Leipsic, Jonathon A.. St. Paul's Hospital; Canadá Fil: Capunay, Carlos. Diagnóstico Maipú; Argentina Fil: De Zan, Macarena C.. Diagnóstico Maipú; Argentina Fil: Goldsmit, Alejandro. Sanatorio Güemes; Argentina Fil: Rodriguez Granillo, Gaston Alfredo. Diagnóstico Maipú; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Cardiológicas. Universidad de Buenos Aires. Facultad de Medicina. Instituto de Investigaciones Cardiológicas; Argentina |
description |
We explored whether intracycle motion correction algorithms (MCAs) might be applicable to dual energy computed tomography coronary angiography in patients with intermediate to high likelihood of coronary artery disease. MCA reconstructions were associated with higher interpretability rates (96.7% vs 87.9%, P < .001), image quality scores (4.12±0.9 vs. 3.76±1.0; P < .0001), and diagnostic performance [area under the curve of 0.95 (95% confidence interval [CI] 0.92-0.97) vs 0.89 (95% CI 0.86-0.92); P < .0001] compared to conventional reconstructions. In conclusion, application of intracycle MCA reconstructions to dual energy computed tomography acquisitions was feasible and resulted in significantly higher image quality scores, interpretability, and diagnostic performance. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-11 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/39073 Carrascosa, Patricia; Deviggiano, Alejandro; Leipsic, Jonathon A.; Capunay, Carlos; De Zan, Macarena C.; et al.; Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease; Elsevier Science Inc; Clinical Imaging; 39; 6; 11-2015; 1000-1005 0899-7071 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/39073 |
identifier_str_mv |
Carrascosa, Patricia; Deviggiano, Alejandro; Leipsic, Jonathon A.; Capunay, Carlos; De Zan, Macarena C.; et al.; Dual energy imaging and intracycle motion correction for CT coronary angiography in patients with intermediate to high likelihood of coronary artery disease; Elsevier Science Inc; Clinical Imaging; 39; 6; 11-2015; 1000-1005 0899-7071 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0899707115001886 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.clinimag.2015.07.023 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/vnd.openxmlformats-officedocument.wordprocessingml.document application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier Science Inc |
publisher.none.fl_str_mv |
Elsevier Science Inc |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1842269324624003072 |
score |
13.13397 |