Implementation of a digital Lock-in amplifier in SoC-FPGA for Biomedical Tomography

Autores
Oliva, Matías Javier; García, Pablo Andrés; Spinelli, Enrique Mario; Veiga, Alejandro Luis
Año de publicación
2022
Idioma
inglés
Tipo de recurso
documento de conferencia
Estado
versión publicada
Descripción
Magnetic Tomography is a technique that uses coil arrangements to determine the conductivity and permeability profile of an object. This is achieved by applying sinusoidal stimuli to a driving coil and measuring the generated signal in a sensing coil. These signals are usually of very low amplitude and poor levels of signal to noise ratio, but the applied stimulus is known, which enables the use of techniques such as the Lock-in amplifier to recover the response. However, the high price of commercially available devices is restrictive, so it is of interest to generate an open design. Heterogeneous embedded systems, which combine an array of programmable logic cells, a processor, peripherals, and shared memory controllers are an interesting tool to implement such a system. In this work the theoretical aspects of the Lock-in amplifier are discussed, showing that its action reduces the noise of the signals in a factor proportional to the bandwidth of the low-pass filter. Then, the design of an open-source Lock-in amplifier with a moving average filter on a DE1-SoC platform is presented, and it is experimentally shown that it reduces the noise of the signals by a factor √(N/2), where N is the number of samples involved in the calculation of the moving average.
La Tomografía Magnética es una técnica que utiliza arreglos de espiras para determinar el perfil de conductividad y permeabilidad de un objeto bajo estudio. Esto se logra aplicando estímulos sinusoidales en una espira excitadora y midiendo la señal generada en una espira sensora. Estas señales suelen ser de muy baja amplitud y pobres niveles de relación señal a ruido, pero, al tener control sobre el estímulo aplicado, se pueden utilizar técnicas como el amplificador Lock-in para recuperar la respuesta. Sin embargo, el elevado precio de los aparatos disponibles resulta restrictivo, por lo que es de interés generar un diseño abierto. Los sistemas embebidos heterogeneos, que combinan un arreglo de celdas lógicas programables, un procesador, periféricos y controladores de memoria compartida, son una herramienta interesante para implementar un sistema como este. En este trabajo se describen los aspectos teóricos del funcionamiento del Lock-in, mostrando que reduce el ruido de las señales en un factor proporcional al ancho de banda del filtro pasa-bajos utilizado. Luego se presenta el diseño de un amplificador Lock-in de código abierto, con un filtro de media móvil en una plataforma DE1-SoC, y se muestra experimentalmente que el ruido de las señales se reduce en un factor √(N/2), donde N es la cantidad de muestras involucradas en el cálculo del promedio móvil.
Instituto de Investigaciones en Electrónica, Control y Procesamiento de Señales
Materia
Ingeniería
Amplificador Lock-in
Diseño Digital
Tomografía Magnética
Instrumentación biomédica
Lock-in amplifier
SoC-FPGA
Magnetic Tomography
Digital design
Biomedical instrumentation
Nivel de accesibilidad
acceso abierto
Condiciones de uso
http://creativecommons.org/licenses/by-nc-nd/4.0/
Repositorio
SEDICI (UNLP)
Institución
Universidad Nacional de La Plata
OAI Identificador
oai:sedici.unlp.edu.ar:10915/160855

id SEDICI_02a8ce2d4a2d7063217a34ed50953d70
oai_identifier_str oai:sedici.unlp.edu.ar:10915/160855
network_acronym_str SEDICI
repository_id_str 1329
network_name_str SEDICI (UNLP)
spelling Implementation of a digital Lock-in amplifier in SoC-FPGA for Biomedical TomographyOliva, Matías JavierGarcía, Pablo AndrésSpinelli, Enrique MarioVeiga, Alejandro LuisIngenieríaAmplificador Lock-inDiseño DigitalTomografía MagnéticaInstrumentación biomédicaLock-in amplifierSoC-FPGAMagnetic TomographyDigital designBiomedical instrumentationMagnetic Tomography is a technique that uses coil arrangements to determine the conductivity and permeability profile of an object. This is achieved by applying sinusoidal stimuli to a driving coil and measuring the generated signal in a sensing coil. These signals are usually of very low amplitude and poor levels of signal to noise ratio, but the applied stimulus is known, which enables the use of techniques such as the Lock-in amplifier to recover the response. However, the high price of commercially available devices is restrictive, so it is of interest to generate an open design. Heterogeneous embedded systems, which combine an array of programmable logic cells, a processor, peripherals, and shared memory controllers are an interesting tool to implement such a system. In this work the theoretical aspects of the Lock-in amplifier are discussed, showing that its action reduces the noise of the signals in a factor proportional to the bandwidth of the low-pass filter. Then, the design of an open-source Lock-in amplifier with a moving average filter on a DE1-SoC platform is presented, and it is experimentally shown that it reduces the noise of the signals by a factor √(N/2), where N is the number of samples involved in the calculation of the moving average.La Tomografía Magnética es una técnica que utiliza arreglos de espiras para determinar el perfil de conductividad y permeabilidad de un objeto bajo estudio. Esto se logra aplicando estímulos sinusoidales en una espira excitadora y midiendo la señal generada en una espira sensora. Estas señales suelen ser de muy baja amplitud y pobres niveles de relación señal a ruido, pero, al tener control sobre el estímulo aplicado, se pueden utilizar técnicas como el amplificador Lock-in para recuperar la respuesta. Sin embargo, el elevado precio de los aparatos disponibles resulta restrictivo, por lo que es de interés generar un diseño abierto. Los sistemas embebidos heterogeneos, que combinan un arreglo de celdas lógicas programables, un procesador, periféricos y controladores de memoria compartida, son una herramienta interesante para implementar un sistema como este. En este trabajo se describen los aspectos teóricos del funcionamiento del Lock-in, mostrando que reduce el ruido de las señales en un factor proporcional al ancho de banda del filtro pasa-bajos utilizado. Luego se presenta el diseño de un amplificador Lock-in de código abierto, con un filtro de media móvil en una plataforma DE1-SoC, y se muestra experimentalmente que el ruido de las señales se reduce en un factor √(N/2), donde N es la cantidad de muestras involucradas en el cálculo del promedio móvil.Instituto de Investigaciones en Electrónica, Control y Procesamiento de Señales2022-09info:eu-repo/semantics/conferenceObjectinfo:eu-repo/semantics/publishedVersionObjeto de conferenciahttp://purl.org/coar/resource_type/c_5794info:ar-repo/semantics/documentoDeConferenciaapplication/pdfhttp://sedici.unlp.edu.ar/handle/10915/160855enginfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/4.0/Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)reponame:SEDICI (UNLP)instname:Universidad Nacional de La Platainstacron:UNLP2025-09-03T11:14:06Zoai:sedici.unlp.edu.ar:10915/160855Institucionalhttp://sedici.unlp.edu.ar/Universidad públicaNo correspondehttp://sedici.unlp.edu.ar/oai/snrdalira@sedici.unlp.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:13292025-09-03 11:14:06.179SEDICI (UNLP) - Universidad Nacional de La Platafalse
dc.title.none.fl_str_mv Implementation of a digital Lock-in amplifier in SoC-FPGA for Biomedical Tomography
title Implementation of a digital Lock-in amplifier in SoC-FPGA for Biomedical Tomography
spellingShingle Implementation of a digital Lock-in amplifier in SoC-FPGA for Biomedical Tomography
Oliva, Matías Javier
Ingeniería
Amplificador Lock-in
Diseño Digital
Tomografía Magnética
Instrumentación biomédica
Lock-in amplifier
SoC-FPGA
Magnetic Tomography
Digital design
Biomedical instrumentation
title_short Implementation of a digital Lock-in amplifier in SoC-FPGA for Biomedical Tomography
title_full Implementation of a digital Lock-in amplifier in SoC-FPGA for Biomedical Tomography
title_fullStr Implementation of a digital Lock-in amplifier in SoC-FPGA for Biomedical Tomography
title_full_unstemmed Implementation of a digital Lock-in amplifier in SoC-FPGA for Biomedical Tomography
title_sort Implementation of a digital Lock-in amplifier in SoC-FPGA for Biomedical Tomography
dc.creator.none.fl_str_mv Oliva, Matías Javier
García, Pablo Andrés
Spinelli, Enrique Mario
Veiga, Alejandro Luis
author Oliva, Matías Javier
author_facet Oliva, Matías Javier
García, Pablo Andrés
Spinelli, Enrique Mario
Veiga, Alejandro Luis
author_role author
author2 García, Pablo Andrés
Spinelli, Enrique Mario
Veiga, Alejandro Luis
author2_role author
author
author
dc.subject.none.fl_str_mv Ingeniería
Amplificador Lock-in
Diseño Digital
Tomografía Magnética
Instrumentación biomédica
Lock-in amplifier
SoC-FPGA
Magnetic Tomography
Digital design
Biomedical instrumentation
topic Ingeniería
Amplificador Lock-in
Diseño Digital
Tomografía Magnética
Instrumentación biomédica
Lock-in amplifier
SoC-FPGA
Magnetic Tomography
Digital design
Biomedical instrumentation
dc.description.none.fl_txt_mv Magnetic Tomography is a technique that uses coil arrangements to determine the conductivity and permeability profile of an object. This is achieved by applying sinusoidal stimuli to a driving coil and measuring the generated signal in a sensing coil. These signals are usually of very low amplitude and poor levels of signal to noise ratio, but the applied stimulus is known, which enables the use of techniques such as the Lock-in amplifier to recover the response. However, the high price of commercially available devices is restrictive, so it is of interest to generate an open design. Heterogeneous embedded systems, which combine an array of programmable logic cells, a processor, peripherals, and shared memory controllers are an interesting tool to implement such a system. In this work the theoretical aspects of the Lock-in amplifier are discussed, showing that its action reduces the noise of the signals in a factor proportional to the bandwidth of the low-pass filter. Then, the design of an open-source Lock-in amplifier with a moving average filter on a DE1-SoC platform is presented, and it is experimentally shown that it reduces the noise of the signals by a factor √(N/2), where N is the number of samples involved in the calculation of the moving average.
La Tomografía Magnética es una técnica que utiliza arreglos de espiras para determinar el perfil de conductividad y permeabilidad de un objeto bajo estudio. Esto se logra aplicando estímulos sinusoidales en una espira excitadora y midiendo la señal generada en una espira sensora. Estas señales suelen ser de muy baja amplitud y pobres niveles de relación señal a ruido, pero, al tener control sobre el estímulo aplicado, se pueden utilizar técnicas como el amplificador Lock-in para recuperar la respuesta. Sin embargo, el elevado precio de los aparatos disponibles resulta restrictivo, por lo que es de interés generar un diseño abierto. Los sistemas embebidos heterogeneos, que combinan un arreglo de celdas lógicas programables, un procesador, periféricos y controladores de memoria compartida, son una herramienta interesante para implementar un sistema como este. En este trabajo se describen los aspectos teóricos del funcionamiento del Lock-in, mostrando que reduce el ruido de las señales en un factor proporcional al ancho de banda del filtro pasa-bajos utilizado. Luego se presenta el diseño de un amplificador Lock-in de código abierto, con un filtro de media móvil en una plataforma DE1-SoC, y se muestra experimentalmente que el ruido de las señales se reduce en un factor √(N/2), donde N es la cantidad de muestras involucradas en el cálculo del promedio móvil.
Instituto de Investigaciones en Electrónica, Control y Procesamiento de Señales
description Magnetic Tomography is a technique that uses coil arrangements to determine the conductivity and permeability profile of an object. This is achieved by applying sinusoidal stimuli to a driving coil and measuring the generated signal in a sensing coil. These signals are usually of very low amplitude and poor levels of signal to noise ratio, but the applied stimulus is known, which enables the use of techniques such as the Lock-in amplifier to recover the response. However, the high price of commercially available devices is restrictive, so it is of interest to generate an open design. Heterogeneous embedded systems, which combine an array of programmable logic cells, a processor, peripherals, and shared memory controllers are an interesting tool to implement such a system. In this work the theoretical aspects of the Lock-in amplifier are discussed, showing that its action reduces the noise of the signals in a factor proportional to the bandwidth of the low-pass filter. Then, the design of an open-source Lock-in amplifier with a moving average filter on a DE1-SoC platform is presented, and it is experimentally shown that it reduces the noise of the signals by a factor √(N/2), where N is the number of samples involved in the calculation of the moving average.
publishDate 2022
dc.date.none.fl_str_mv 2022-09
dc.type.none.fl_str_mv info:eu-repo/semantics/conferenceObject
info:eu-repo/semantics/publishedVersion
Objeto de conferencia
http://purl.org/coar/resource_type/c_5794
info:ar-repo/semantics/documentoDeConferencia
format conferenceObject
status_str publishedVersion
dc.identifier.none.fl_str_mv http://sedici.unlp.edu.ar/handle/10915/160855
url http://sedici.unlp.edu.ar/handle/10915/160855
dc.language.none.fl_str_mv eng
language eng
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
http://creativecommons.org/licenses/by-nc-nd/4.0/
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:SEDICI (UNLP)
instname:Universidad Nacional de La Plata
instacron:UNLP
reponame_str SEDICI (UNLP)
collection SEDICI (UNLP)
instname_str Universidad Nacional de La Plata
instacron_str UNLP
institution UNLP
repository.name.fl_str_mv SEDICI (UNLP) - Universidad Nacional de La Plata
repository.mail.fl_str_mv alira@sedici.unlp.edu.ar
_version_ 1842260646152896512