Electrochemical immunosensor for the determination of β-casein
- Autores
- Molinari, J.; Moina, C.; Ybarra, G.
- Año de publicación
- 2015
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- An amperometric biosensor for the quantification of food allergens based on an inhibitory immunoassay is presented. As a proof of concept, the experimental conditions were optimized for the detection of β-casein in the 0-10 ppm range. Eight electrochemical cells were integrated into a small-sized portable potentiostat controlled by a smartphone via Bluetooth communication. The determination of β-casein in eight different samples can be measured with the electrochemical biosensor, which has the potential to be modified for the detection of multiple allergens.
Fil: Molinari, J. Instituto Nacional de Tecnología Industrial. INTI-Procesos Superficiales; Argentina
Fil: Moina, C. Instituto Nacional de Tecnología Industrial. INTI-Procesos Superficiales; Argentina
Fil: Ybarra, G. Instituto Nacional de Tecnología Industrial. INTI-Procesos Superficiales; Argentina - Fuente
- Journal of Electrochemical Science and Engineering, 5(1)
- Materia
-
Sensores electroquímicos
Inmunosensores
Caseína
Células
Biosensores
Alergenos
Alimentos alergénicos - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by/4.0/
- Repositorio
- Institución
- Instituto Nacional de Tecnología Industrial
- OAI Identificador
- nuevadc:Molinari2015Electrochemical_pdf
Ver los metadatos del registro completo
id |
RIINTI_99beddc00f070df5e27dcaced7717d13 |
---|---|
oai_identifier_str |
nuevadc:Molinari2015Electrochemical_pdf |
network_acronym_str |
RIINTI |
repository_id_str |
|
network_name_str |
Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI) |
spelling |
Electrochemical immunosensor for the determination of β-caseinMolinari, J.Moina, C.Ybarra, G.Sensores electroquímicosInmunosensoresCaseínaCélulasBiosensoresAlergenosAlimentos alergénicosAn amperometric biosensor for the quantification of food allergens based on an inhibitory immunoassay is presented. As a proof of concept, the experimental conditions were optimized for the detection of β-casein in the 0-10 ppm range. Eight electrochemical cells were integrated into a small-sized portable potentiostat controlled by a smartphone via Bluetooth communication. The determination of β-casein in eight different samples can be measured with the electrochemical biosensor, which has the potential to be modified for the detection of multiple allergens.Fil: Molinari, J. Instituto Nacional de Tecnología Industrial. INTI-Procesos Superficiales; ArgentinaFil: Moina, C. Instituto Nacional de Tecnología Industrial. INTI-Procesos Superficiales; ArgentinaFil: Ybarra, G. Instituto Nacional de Tecnología Industrial. INTI-Procesos Superficiales; ArgentinaIAPC2015info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfMolinari2015Electrochemical.pdfhttps://app.inti.gob.ar/greenstone3/sites/localsite/collect/nuevadc/index/assoc/Molinari.dir/doc.pdfJournal of Electrochemical Science and Engineering, 5(1)reponame:Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI)instname:Instituto Nacional de Tecnología Industrialenginfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/4.0/openAccess2025-09-29T15:01:59Znuevadc:Molinari2015Electrochemical_pdfinstacron:INTIInstitucionalhttps://app.inti.gob.ar/greenstone3/biblioOrganismo científico-tecnológicohttps://argentina.gob.ar/intihttps://app.inti.gob.ar/greenstone3/oaiserver?verb=Identifypfalcato@inti.gob.arArgentinaopendoar:2025-09-29 15:02:00.461Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI) - Instituto Nacional de Tecnología Industrialfalse |
dc.title.none.fl_str_mv |
Electrochemical immunosensor for the determination of β-casein |
title |
Electrochemical immunosensor for the determination of β-casein |
spellingShingle |
Electrochemical immunosensor for the determination of β-casein Molinari, J. Sensores electroquímicos Inmunosensores Caseína Células Biosensores Alergenos Alimentos alergénicos |
title_short |
Electrochemical immunosensor for the determination of β-casein |
title_full |
Electrochemical immunosensor for the determination of β-casein |
title_fullStr |
Electrochemical immunosensor for the determination of β-casein |
title_full_unstemmed |
Electrochemical immunosensor for the determination of β-casein |
title_sort |
Electrochemical immunosensor for the determination of β-casein |
dc.creator.none.fl_str_mv |
Molinari, J. Moina, C. Ybarra, G. |
author |
Molinari, J. |
author_facet |
Molinari, J. Moina, C. Ybarra, G. |
author_role |
author |
author2 |
Moina, C. Ybarra, G. |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Sensores electroquímicos Inmunosensores Caseína Células Biosensores Alergenos Alimentos alergénicos |
topic |
Sensores electroquímicos Inmunosensores Caseína Células Biosensores Alergenos Alimentos alergénicos |
dc.description.none.fl_txt_mv |
An amperometric biosensor for the quantification of food allergens based on an inhibitory immunoassay is presented. As a proof of concept, the experimental conditions were optimized for the detection of β-casein in the 0-10 ppm range. Eight electrochemical cells were integrated into a small-sized portable potentiostat controlled by a smartphone via Bluetooth communication. The determination of β-casein in eight different samples can be measured with the electrochemical biosensor, which has the potential to be modified for the detection of multiple allergens. Fil: Molinari, J. Instituto Nacional de Tecnología Industrial. INTI-Procesos Superficiales; Argentina Fil: Moina, C. Instituto Nacional de Tecnología Industrial. INTI-Procesos Superficiales; Argentina Fil: Ybarra, G. Instituto Nacional de Tecnología Industrial. INTI-Procesos Superficiales; Argentina |
description |
An amperometric biosensor for the quantification of food allergens based on an inhibitory immunoassay is presented. As a proof of concept, the experimental conditions were optimized for the detection of β-casein in the 0-10 ppm range. Eight electrochemical cells were integrated into a small-sized portable potentiostat controlled by a smartphone via Bluetooth communication. The determination of β-casein in eight different samples can be measured with the electrochemical biosensor, which has the potential to be modified for the detection of multiple allergens. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
Molinari2015Electrochemical.pdf https://app.inti.gob.ar/greenstone3/sites/localsite/collect/nuevadc/index/assoc/Molinari.dir/doc.pdf |
identifier_str_mv |
Molinari2015Electrochemical.pdf |
url |
https://app.inti.gob.ar/greenstone3/sites/localsite/collect/nuevadc/index/assoc/Molinari.dir/doc.pdf |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by/4.0/ openAccess |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0/ openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
IAPC |
publisher.none.fl_str_mv |
IAPC |
dc.source.none.fl_str_mv |
Journal of Electrochemical Science and Engineering, 5(1) reponame:Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI) instname:Instituto Nacional de Tecnología Industrial |
reponame_str |
Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI) |
collection |
Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI) |
instname_str |
Instituto Nacional de Tecnología Industrial |
repository.name.fl_str_mv |
Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI) - Instituto Nacional de Tecnología Industrial |
repository.mail.fl_str_mv |
pfalcato@inti.gob.ar |
_version_ |
1844623654615252992 |
score |
12.559606 |