Estimation of Band Broadening in Size Exclusion Chromatography. I. Theoretical Method Based on Analyzing Narrow Standards with a Molar Mass-Sensitive Detector

Autores
Yossen, Mariana Matilde; Vega, Jorge Ruben; Meira, Gregorio Raul
Año de publicación
2006
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
A method is proposed for estimating the (asymmetrical and non-uniform) band broadening function (BBF) in size-exclusion chromatography (SEC). The following data are required: the molar mass calibration and the concentration- and molar mass chromatograms of a set of narrow standards. In the narrow range of each standard, the BBF is uniform but skewed. Each uniform BBF is estimated through a nonlinear optimization procedure that compares one (of the two) measured chromatograms with its theoretical prediction based on the other chromatogram. The method is validated with numerical examples that simulate the analyses of narrow standards exhibiting log-normal and Poisson weight chain length distributions. The BBF can be assumed of arbitrary shape, or represented by an exponentially-modified Gaussian (EMG). From the uniform BBF estimate, the true polydispersity of the standard can be determined. The global non-uniform BBF is obtained by interpolation between a set of uniform BBFs covering a wide range of elution volumes.
Fil: Yossen, Mariana Matilde. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina
Fil: Vega, Jorge Ruben. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina
Fil: Meira, Gregorio Raul. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/26398

id CONICETDig_f3e9591b20bc931746367d7a968351cf
oai_identifier_str oai:ri.conicet.gov.ar:11336/26398
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Estimation of Band Broadening in Size Exclusion Chromatography. I. Theoretical Method Based on Analyzing Narrow Standards with a Molar Mass-Sensitive DetectorYossen, Mariana MatildeVega, Jorge RubenMeira, Gregorio Raulhttps://purl.org/becyt/ford/2.4https://purl.org/becyt/ford/2A method is proposed for estimating the (asymmetrical and non-uniform) band broadening function (BBF) in size-exclusion chromatography (SEC). The following data are required: the molar mass calibration and the concentration- and molar mass chromatograms of a set of narrow standards. In the narrow range of each standard, the BBF is uniform but skewed. Each uniform BBF is estimated through a nonlinear optimization procedure that compares one (of the two) measured chromatograms with its theoretical prediction based on the other chromatogram. The method is validated with numerical examples that simulate the analyses of narrow standards exhibiting log-normal and Poisson weight chain length distributions. The BBF can be assumed of arbitrary shape, or represented by an exponentially-modified Gaussian (EMG). From the uniform BBF estimate, the true polydispersity of the standard can be determined. The global non-uniform BBF is obtained by interpolation between a set of uniform BBFs covering a wide range of elution volumes.Fil: Yossen, Mariana Matilde. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; ArgentinaFil: Vega, Jorge Ruben. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; ArgentinaFil: Meira, Gregorio Raul. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; ArgentinaElsevier Science2006-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/26398Yossen, Mariana Matilde; Vega, Jorge Ruben; Meira, Gregorio Raul; Estimation of Band Broadening in Size Exclusion Chromatography. I. Theoretical Method Based on Analyzing Narrow Standards with a Molar Mass-Sensitive Detector; Elsevier Science; Journal Of Chromatography - A; 1128; 1-2; 12-2006; 171-1800021-9673CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S002196730601243Xinfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.chroma.2006.06.062info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-15T15:08:31Zoai:ri.conicet.gov.ar:11336/26398instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-15 15:08:31.71CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Estimation of Band Broadening in Size Exclusion Chromatography. I. Theoretical Method Based on Analyzing Narrow Standards with a Molar Mass-Sensitive Detector
title Estimation of Band Broadening in Size Exclusion Chromatography. I. Theoretical Method Based on Analyzing Narrow Standards with a Molar Mass-Sensitive Detector
spellingShingle Estimation of Band Broadening in Size Exclusion Chromatography. I. Theoretical Method Based on Analyzing Narrow Standards with a Molar Mass-Sensitive Detector
Yossen, Mariana Matilde
title_short Estimation of Band Broadening in Size Exclusion Chromatography. I. Theoretical Method Based on Analyzing Narrow Standards with a Molar Mass-Sensitive Detector
title_full Estimation of Band Broadening in Size Exclusion Chromatography. I. Theoretical Method Based on Analyzing Narrow Standards with a Molar Mass-Sensitive Detector
title_fullStr Estimation of Band Broadening in Size Exclusion Chromatography. I. Theoretical Method Based on Analyzing Narrow Standards with a Molar Mass-Sensitive Detector
title_full_unstemmed Estimation of Band Broadening in Size Exclusion Chromatography. I. Theoretical Method Based on Analyzing Narrow Standards with a Molar Mass-Sensitive Detector
title_sort Estimation of Band Broadening in Size Exclusion Chromatography. I. Theoretical Method Based on Analyzing Narrow Standards with a Molar Mass-Sensitive Detector
dc.creator.none.fl_str_mv Yossen, Mariana Matilde
Vega, Jorge Ruben
Meira, Gregorio Raul
author Yossen, Mariana Matilde
author_facet Yossen, Mariana Matilde
Vega, Jorge Ruben
Meira, Gregorio Raul
author_role author
author2 Vega, Jorge Ruben
Meira, Gregorio Raul
author2_role author
author
purl_subject.fl_str_mv https://purl.org/becyt/ford/2.4
https://purl.org/becyt/ford/2
dc.description.none.fl_txt_mv A method is proposed for estimating the (asymmetrical and non-uniform) band broadening function (BBF) in size-exclusion chromatography (SEC). The following data are required: the molar mass calibration and the concentration- and molar mass chromatograms of a set of narrow standards. In the narrow range of each standard, the BBF is uniform but skewed. Each uniform BBF is estimated through a nonlinear optimization procedure that compares one (of the two) measured chromatograms with its theoretical prediction based on the other chromatogram. The method is validated with numerical examples that simulate the analyses of narrow standards exhibiting log-normal and Poisson weight chain length distributions. The BBF can be assumed of arbitrary shape, or represented by an exponentially-modified Gaussian (EMG). From the uniform BBF estimate, the true polydispersity of the standard can be determined. The global non-uniform BBF is obtained by interpolation between a set of uniform BBFs covering a wide range of elution volumes.
Fil: Yossen, Mariana Matilde. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina
Fil: Vega, Jorge Ruben. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina
Fil: Meira, Gregorio Raul. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina
description A method is proposed for estimating the (asymmetrical and non-uniform) band broadening function (BBF) in size-exclusion chromatography (SEC). The following data are required: the molar mass calibration and the concentration- and molar mass chromatograms of a set of narrow standards. In the narrow range of each standard, the BBF is uniform but skewed. Each uniform BBF is estimated through a nonlinear optimization procedure that compares one (of the two) measured chromatograms with its theoretical prediction based on the other chromatogram. The method is validated with numerical examples that simulate the analyses of narrow standards exhibiting log-normal and Poisson weight chain length distributions. The BBF can be assumed of arbitrary shape, or represented by an exponentially-modified Gaussian (EMG). From the uniform BBF estimate, the true polydispersity of the standard can be determined. The global non-uniform BBF is obtained by interpolation between a set of uniform BBFs covering a wide range of elution volumes.
publishDate 2006
dc.date.none.fl_str_mv 2006-12
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/26398
Yossen, Mariana Matilde; Vega, Jorge Ruben; Meira, Gregorio Raul; Estimation of Band Broadening in Size Exclusion Chromatography. I. Theoretical Method Based on Analyzing Narrow Standards with a Molar Mass-Sensitive Detector; Elsevier Science; Journal Of Chromatography - A; 1128; 1-2; 12-2006; 171-180
0021-9673
CONICET Digital
CONICET
url http://hdl.handle.net/11336/26398
identifier_str_mv Yossen, Mariana Matilde; Vega, Jorge Ruben; Meira, Gregorio Raul; Estimation of Band Broadening in Size Exclusion Chromatography. I. Theoretical Method Based on Analyzing Narrow Standards with a Molar Mass-Sensitive Detector; Elsevier Science; Journal Of Chromatography - A; 1128; 1-2; 12-2006; 171-180
0021-9673
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S002196730601243X
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.chroma.2006.06.062
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier Science
publisher.none.fl_str_mv Elsevier Science
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1846083231910199296
score 13.221938