Intrinsic viscosity determination by ‘single-point’ and ‘double-point’ equations
- Autores
- Curvale, Rolando; Cesco, Juan Carlos
- Año de publicación
- 2009
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- "Single-point" equations used for intrinsic viscosity determination are greatly used when working with synthetic polymer solution systems. In this work we have applied them to a biological macromolecule in a bovine serum albumin (BSA)/water system. Almost all single-point equations are available and errors can be lowered. However, we have detected a systematic bias in the estimations provided by "single-point" methods. To overcome it we propose a "double-point" method which gives lower estimation errors for this system. This novel method is not system specific and could be applied to other polymeric solution.
Fil: Curvale, Rolando. Universidad Nacional de San Luis; Argentina
Fil: Cesco, Juan Carlos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Matemática Aplicada de San Luis "Prof. Ezio Marchi". Universidad Nacional de San Luis. Facultad de Ciencias Físico, Matemáticas y Naturales. Instituto de Matemática Aplicada de San Luis "Prof. Ezio Marchi"; Argentina - Materia
-
VISCOSITY
DETERMINATION - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/235754
Ver los metadatos del registro completo
id |
CONICETDig_dc095a643dc1c6396028aa31c32dcee3 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/235754 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Intrinsic viscosity determination by ‘single-point’ and ‘double-point’ equationsCurvale, RolandoCesco, Juan CarlosVISCOSITYDETERMINATIONhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1"Single-point" equations used for intrinsic viscosity determination are greatly used when working with synthetic polymer solution systems. In this work we have applied them to a biological macromolecule in a bovine serum albumin (BSA)/water system. Almost all single-point equations are available and errors can be lowered. However, we have detected a systematic bias in the estimations provided by "single-point" methods. To overcome it we propose a "double-point" method which gives lower estimation errors for this system. This novel method is not system specific and could be applied to other polymeric solution.Fil: Curvale, Rolando. Universidad Nacional de San Luis; ArgentinaFil: Cesco, Juan Carlos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Matemática Aplicada de San Luis "Prof. Ezio Marchi". Universidad Nacional de San Luis. Facultad de Ciencias Físico, Matemáticas y Naturales. Instituto de Matemática Aplicada de San Luis "Prof. Ezio Marchi"; ArgentinaKerschensteiner Verlag2009-10info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/235754Curvale, Rolando; Cesco, Juan Carlos; Intrinsic viscosity determination by ‘single-point’ and ‘double-point’ equations; Kerschensteiner Verlag; Applied Rheology; 19; 5; 10-2009; 1-61617-8106CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.3933/ApplRheol-19-53347info:eu-repo/semantics/altIdentifier/url/https://www.complexfluids.ethz.ch/cgi-bin/AR/ar_contents?DC=1&DOI=10.3933/ApplRheol-19-53347&human=yesinfo:eu-repo/semantics/altIdentifier/url/https://www.complexfluids.ethz.ch/AR/GOOGLE/DOI:10.3933/ApplRheol-19-53347-extract.pdfinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:25:37Zoai:ri.conicet.gov.ar:11336/235754instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:25:38.276CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Intrinsic viscosity determination by ‘single-point’ and ‘double-point’ equations |
title |
Intrinsic viscosity determination by ‘single-point’ and ‘double-point’ equations |
spellingShingle |
Intrinsic viscosity determination by ‘single-point’ and ‘double-point’ equations Curvale, Rolando VISCOSITY DETERMINATION |
title_short |
Intrinsic viscosity determination by ‘single-point’ and ‘double-point’ equations |
title_full |
Intrinsic viscosity determination by ‘single-point’ and ‘double-point’ equations |
title_fullStr |
Intrinsic viscosity determination by ‘single-point’ and ‘double-point’ equations |
title_full_unstemmed |
Intrinsic viscosity determination by ‘single-point’ and ‘double-point’ equations |
title_sort |
Intrinsic viscosity determination by ‘single-point’ and ‘double-point’ equations |
dc.creator.none.fl_str_mv |
Curvale, Rolando Cesco, Juan Carlos |
author |
Curvale, Rolando |
author_facet |
Curvale, Rolando Cesco, Juan Carlos |
author_role |
author |
author2 |
Cesco, Juan Carlos |
author2_role |
author |
dc.subject.none.fl_str_mv |
VISCOSITY DETERMINATION |
topic |
VISCOSITY DETERMINATION |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
"Single-point" equations used for intrinsic viscosity determination are greatly used when working with synthetic polymer solution systems. In this work we have applied them to a biological macromolecule in a bovine serum albumin (BSA)/water system. Almost all single-point equations are available and errors can be lowered. However, we have detected a systematic bias in the estimations provided by "single-point" methods. To overcome it we propose a "double-point" method which gives lower estimation errors for this system. This novel method is not system specific and could be applied to other polymeric solution. Fil: Curvale, Rolando. Universidad Nacional de San Luis; Argentina Fil: Cesco, Juan Carlos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Matemática Aplicada de San Luis "Prof. Ezio Marchi". Universidad Nacional de San Luis. Facultad de Ciencias Físico, Matemáticas y Naturales. Instituto de Matemática Aplicada de San Luis "Prof. Ezio Marchi"; Argentina |
description |
"Single-point" equations used for intrinsic viscosity determination are greatly used when working with synthetic polymer solution systems. In this work we have applied them to a biological macromolecule in a bovine serum albumin (BSA)/water system. Almost all single-point equations are available and errors can be lowered. However, we have detected a systematic bias in the estimations provided by "single-point" methods. To overcome it we propose a "double-point" method which gives lower estimation errors for this system. This novel method is not system specific and could be applied to other polymeric solution. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-10 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/235754 Curvale, Rolando; Cesco, Juan Carlos; Intrinsic viscosity determination by ‘single-point’ and ‘double-point’ equations; Kerschensteiner Verlag; Applied Rheology; 19; 5; 10-2009; 1-6 1617-8106 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/235754 |
identifier_str_mv |
Curvale, Rolando; Cesco, Juan Carlos; Intrinsic viscosity determination by ‘single-point’ and ‘double-point’ equations; Kerschensteiner Verlag; Applied Rheology; 19; 5; 10-2009; 1-6 1617-8106 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.3933/ApplRheol-19-53347 info:eu-repo/semantics/altIdentifier/url/https://www.complexfluids.ethz.ch/cgi-bin/AR/ar_contents?DC=1&DOI=10.3933/ApplRheol-19-53347&human=yes info:eu-repo/semantics/altIdentifier/url/https://www.complexfluids.ethz.ch/AR/GOOGLE/DOI:10.3933/ApplRheol-19-53347-extract.pdf |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Kerschensteiner Verlag |
publisher.none.fl_str_mv |
Kerschensteiner Verlag |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844614255339372544 |
score |
13.070432 |