Normalization method for J-R curve determination using SENT specimens

Autores
Menezes, João Teixeira Oliveira de; Perez Ipiña, Juan Elias; Castrodeza, Enrique M.
Año de publicación
2018
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
According to BS 8571:2014, standard J-R curves from SENT geometry can be determined from single or multiple specimens. The recommended methodologies for single specimen include unloading compliance or DCPD, although any validated technique can be used. The normalization method, which is not directly recommended in BSI standards, is an alternative. J-R curves through normalization technique based on P-CMOD records were experimentally determined using SENT specimens (0.40 < a0/W < 0.55) of two structural steels, later compared with the ones measured by unloading compliance. Results indicated that the normalization method is a valid alternative for J-R curve determination using SENT specimens.
Fil: Menezes, João Teixeira Oliveira de. Universidade Federal do Rio de Janeiro; Brasil
Fil: Perez Ipiña, Juan Elias. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional del Comahue; Argentina
Fil: Castrodeza, Enrique M.. Universidade Federal do Rio de Janeiro; Brasil
Materia
J-R CURVES
NORMALIZATION METHOD
SENT GEOMETRY
STRUCTURAL STEELS
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/109499

id CONICETDig_928bd771b72fd667cebe691143d0c340
oai_identifier_str oai:ri.conicet.gov.ar:11336/109499
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Normalization method for J-R curve determination using SENT specimensMenezes, João Teixeira Oliveira dePerez Ipiña, Juan EliasCastrodeza, Enrique M.J-R CURVESNORMALIZATION METHODSENT GEOMETRYSTRUCTURAL STEELShttps://purl.org/becyt/ford/2.5https://purl.org/becyt/ford/2According to BS 8571:2014, standard J-R curves from SENT geometry can be determined from single or multiple specimens. The recommended methodologies for single specimen include unloading compliance or DCPD, although any validated technique can be used. The normalization method, which is not directly recommended in BSI standards, is an alternative. J-R curves through normalization technique based on P-CMOD records were experimentally determined using SENT specimens (0.40 < a0/W < 0.55) of two structural steels, later compared with the ones measured by unloading compliance. Results indicated that the normalization method is a valid alternative for J-R curve determination using SENT specimens.Fil: Menezes, João Teixeira Oliveira de. Universidade Federal do Rio de Janeiro; BrasilFil: Perez Ipiña, Juan Elias. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional del Comahue; ArgentinaFil: Castrodeza, Enrique M.. Universidade Federal do Rio de Janeiro; BrasilPergamon-Elsevier Science Ltd2018-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/109499Menezes, João Teixeira Oliveira de; Perez Ipiña, Juan Elias; Castrodeza, Enrique M.; Normalization method for J-R curve determination using SENT specimens; Pergamon-Elsevier Science Ltd; Engineering Fracture Mechanics; 199; 8-2018; 658-6710013-7944CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.engfracmech.2018.06.033info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S001379441830290Xinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:30:34Zoai:ri.conicet.gov.ar:11336/109499instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:30:34.534CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Normalization method for J-R curve determination using SENT specimens
title Normalization method for J-R curve determination using SENT specimens
spellingShingle Normalization method for J-R curve determination using SENT specimens
Menezes, João Teixeira Oliveira de
J-R CURVES
NORMALIZATION METHOD
SENT GEOMETRY
STRUCTURAL STEELS
title_short Normalization method for J-R curve determination using SENT specimens
title_full Normalization method for J-R curve determination using SENT specimens
title_fullStr Normalization method for J-R curve determination using SENT specimens
title_full_unstemmed Normalization method for J-R curve determination using SENT specimens
title_sort Normalization method for J-R curve determination using SENT specimens
dc.creator.none.fl_str_mv Menezes, João Teixeira Oliveira de
Perez Ipiña, Juan Elias
Castrodeza, Enrique M.
author Menezes, João Teixeira Oliveira de
author_facet Menezes, João Teixeira Oliveira de
Perez Ipiña, Juan Elias
Castrodeza, Enrique M.
author_role author
author2 Perez Ipiña, Juan Elias
Castrodeza, Enrique M.
author2_role author
author
dc.subject.none.fl_str_mv J-R CURVES
NORMALIZATION METHOD
SENT GEOMETRY
STRUCTURAL STEELS
topic J-R CURVES
NORMALIZATION METHOD
SENT GEOMETRY
STRUCTURAL STEELS
purl_subject.fl_str_mv https://purl.org/becyt/ford/2.5
https://purl.org/becyt/ford/2
dc.description.none.fl_txt_mv According to BS 8571:2014, standard J-R curves from SENT geometry can be determined from single or multiple specimens. The recommended methodologies for single specimen include unloading compliance or DCPD, although any validated technique can be used. The normalization method, which is not directly recommended in BSI standards, is an alternative. J-R curves through normalization technique based on P-CMOD records were experimentally determined using SENT specimens (0.40 < a0/W < 0.55) of two structural steels, later compared with the ones measured by unloading compliance. Results indicated that the normalization method is a valid alternative for J-R curve determination using SENT specimens.
Fil: Menezes, João Teixeira Oliveira de. Universidade Federal do Rio de Janeiro; Brasil
Fil: Perez Ipiña, Juan Elias. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional del Comahue; Argentina
Fil: Castrodeza, Enrique M.. Universidade Federal do Rio de Janeiro; Brasil
description According to BS 8571:2014, standard J-R curves from SENT geometry can be determined from single or multiple specimens. The recommended methodologies for single specimen include unloading compliance or DCPD, although any validated technique can be used. The normalization method, which is not directly recommended in BSI standards, is an alternative. J-R curves through normalization technique based on P-CMOD records were experimentally determined using SENT specimens (0.40 < a0/W < 0.55) of two structural steels, later compared with the ones measured by unloading compliance. Results indicated that the normalization method is a valid alternative for J-R curve determination using SENT specimens.
publishDate 2018
dc.date.none.fl_str_mv 2018-08
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/109499
Menezes, João Teixeira Oliveira de; Perez Ipiña, Juan Elias; Castrodeza, Enrique M.; Normalization method for J-R curve determination using SENT specimens; Pergamon-Elsevier Science Ltd; Engineering Fracture Mechanics; 199; 8-2018; 658-671
0013-7944
CONICET Digital
CONICET
url http://hdl.handle.net/11336/109499
identifier_str_mv Menezes, João Teixeira Oliveira de; Perez Ipiña, Juan Elias; Castrodeza, Enrique M.; Normalization method for J-R curve determination using SENT specimens; Pergamon-Elsevier Science Ltd; Engineering Fracture Mechanics; 199; 8-2018; 658-671
0013-7944
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/10.1016/j.engfracmech.2018.06.033
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S001379441830290X
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Pergamon-Elsevier Science Ltd
publisher.none.fl_str_mv Pergamon-Elsevier Science Ltd
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844614314039705600
score 13.070432