How low does the oxygen concentration go within a sandwich-type amperometric biosensor?
- Autores
- Romero, Marcelo Ricardo; Baruzzi, Ana Maria; Garay, Fernando Sebastian
- Año de publicación
- 2012
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Software for the automatic non-linear least squares fit of chronoamperometric responses corresponding to sandwich-type amperometric biosensors has been developed. The so-called Simplex algorithm computes a minimum value for the difference between experimental and theoretical data. The latter consider a numerical model based on a ping-pong reaction mechanism corresponding to an oxidase enzyme that has been immobilized between diffusion membranes. The results obtained from the simulation of a first-generation lactate biosensor in presence of 0.1 mM substrate indicate that the concentration of O 2 would decrease only 0.1% with regards to its bulk value. Besides, the concentration of this natural mediator would remain practically unchanged during a typical calibration curve. This is because the rather high diffusion coefficient of O 2 and its regeneration at the electrode surface minimize the concentration changes of this species. In addition, it was found that the thicknesses of polycarbonate membranes and the enzymatic matrix have average values of 13 μm and 20 μm, respectively. However, these membranes might exhibit smaller thickness depending on the time provided for the crosslinking reaction. In this regard, if this reaction is slow enough, the enzymatic matrix would be able to diffuse through the pores of polycarbonate membranes and they will appear to be thinner than expected. This effect may compromise the response-time and the reproducibility of this kind of biosensors.
Fil: Romero, Marcelo Ricardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto Multidisciplinario de Biología Vegetal. Universidad Nacional de Córdoba. Facultad de Ciencias Exactas Físicas y Naturales. Instituto Multidisciplinario de Biología Vegetal; Argentina
Fil: Baruzzi, Ana Maria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina
Fil: Garay, Fernando Sebastian. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina - Materia
-
AMPEROMETRIC SENSOR
HYDROGEL
OXIDASE
PING-PONG
SANDWICH-TYPE BIOSENSOR
SIMPLEX - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
.jpg)
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/113315
Ver los metadatos del registro completo
| id |
CONICETDig_8135c19b812c69f62d87296fb1232850 |
|---|---|
| oai_identifier_str |
oai:ri.conicet.gov.ar:11336/113315 |
| network_acronym_str |
CONICETDig |
| repository_id_str |
3498 |
| network_name_str |
CONICET Digital (CONICET) |
| spelling |
How low does the oxygen concentration go within a sandwich-type amperometric biosensor?Romero, Marcelo RicardoBaruzzi, Ana MariaGaray, Fernando SebastianAMPEROMETRIC SENSORHYDROGELOXIDASEPING-PONGSANDWICH-TYPE BIOSENSORSIMPLEXhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1Software for the automatic non-linear least squares fit of chronoamperometric responses corresponding to sandwich-type amperometric biosensors has been developed. The so-called Simplex algorithm computes a minimum value for the difference between experimental and theoretical data. The latter consider a numerical model based on a ping-pong reaction mechanism corresponding to an oxidase enzyme that has been immobilized between diffusion membranes. The results obtained from the simulation of a first-generation lactate biosensor in presence of 0.1 mM substrate indicate that the concentration of O 2 would decrease only 0.1% with regards to its bulk value. Besides, the concentration of this natural mediator would remain practically unchanged during a typical calibration curve. This is because the rather high diffusion coefficient of O 2 and its regeneration at the electrode surface minimize the concentration changes of this species. In addition, it was found that the thicknesses of polycarbonate membranes and the enzymatic matrix have average values of 13 μm and 20 μm, respectively. However, these membranes might exhibit smaller thickness depending on the time provided for the crosslinking reaction. In this regard, if this reaction is slow enough, the enzymatic matrix would be able to diffuse through the pores of polycarbonate membranes and they will appear to be thinner than expected. This effect may compromise the response-time and the reproducibility of this kind of biosensors.Fil: Romero, Marcelo Ricardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto Multidisciplinario de Biología Vegetal. Universidad Nacional de Córdoba. Facultad de Ciencias Exactas Físicas y Naturales. Instituto Multidisciplinario de Biología Vegetal; ArgentinaFil: Baruzzi, Ana Maria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Garay, Fernando Sebastian. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaElsevier Science Sa2012-11info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/113315Romero, Marcelo Ricardo; Baruzzi, Ana Maria; Garay, Fernando Sebastian; How low does the oxygen concentration go within a sandwich-type amperometric biosensor?; Elsevier Science Sa; Sensors and Actuators B: Chemical; 174; 11-2012; 279-2840925-4005CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0925400512008416#info:eu-repo/semantics/altIdentifier/doi/10.1016/j.snb.2012.08.027info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-29T12:33:39Zoai:ri.conicet.gov.ar:11336/113315instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-29 12:33:39.319CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
| dc.title.none.fl_str_mv |
How low does the oxygen concentration go within a sandwich-type amperometric biosensor? |
| title |
How low does the oxygen concentration go within a sandwich-type amperometric biosensor? |
| spellingShingle |
How low does the oxygen concentration go within a sandwich-type amperometric biosensor? Romero, Marcelo Ricardo AMPEROMETRIC SENSOR HYDROGEL OXIDASE PING-PONG SANDWICH-TYPE BIOSENSOR SIMPLEX |
| title_short |
How low does the oxygen concentration go within a sandwich-type amperometric biosensor? |
| title_full |
How low does the oxygen concentration go within a sandwich-type amperometric biosensor? |
| title_fullStr |
How low does the oxygen concentration go within a sandwich-type amperometric biosensor? |
| title_full_unstemmed |
How low does the oxygen concentration go within a sandwich-type amperometric biosensor? |
| title_sort |
How low does the oxygen concentration go within a sandwich-type amperometric biosensor? |
| dc.creator.none.fl_str_mv |
Romero, Marcelo Ricardo Baruzzi, Ana Maria Garay, Fernando Sebastian |
| author |
Romero, Marcelo Ricardo |
| author_facet |
Romero, Marcelo Ricardo Baruzzi, Ana Maria Garay, Fernando Sebastian |
| author_role |
author |
| author2 |
Baruzzi, Ana Maria Garay, Fernando Sebastian |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
AMPEROMETRIC SENSOR HYDROGEL OXIDASE PING-PONG SANDWICH-TYPE BIOSENSOR SIMPLEX |
| topic |
AMPEROMETRIC SENSOR HYDROGEL OXIDASE PING-PONG SANDWICH-TYPE BIOSENSOR SIMPLEX |
| purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
| dc.description.none.fl_txt_mv |
Software for the automatic non-linear least squares fit of chronoamperometric responses corresponding to sandwich-type amperometric biosensors has been developed. The so-called Simplex algorithm computes a minimum value for the difference between experimental and theoretical data. The latter consider a numerical model based on a ping-pong reaction mechanism corresponding to an oxidase enzyme that has been immobilized between diffusion membranes. The results obtained from the simulation of a first-generation lactate biosensor in presence of 0.1 mM substrate indicate that the concentration of O 2 would decrease only 0.1% with regards to its bulk value. Besides, the concentration of this natural mediator would remain practically unchanged during a typical calibration curve. This is because the rather high diffusion coefficient of O 2 and its regeneration at the electrode surface minimize the concentration changes of this species. In addition, it was found that the thicknesses of polycarbonate membranes and the enzymatic matrix have average values of 13 μm and 20 μm, respectively. However, these membranes might exhibit smaller thickness depending on the time provided for the crosslinking reaction. In this regard, if this reaction is slow enough, the enzymatic matrix would be able to diffuse through the pores of polycarbonate membranes and they will appear to be thinner than expected. This effect may compromise the response-time and the reproducibility of this kind of biosensors. Fil: Romero, Marcelo Ricardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto Multidisciplinario de Biología Vegetal. Universidad Nacional de Córdoba. Facultad de Ciencias Exactas Físicas y Naturales. Instituto Multidisciplinario de Biología Vegetal; Argentina Fil: Baruzzi, Ana Maria. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina Fil: Garay, Fernando Sebastian. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina |
| description |
Software for the automatic non-linear least squares fit of chronoamperometric responses corresponding to sandwich-type amperometric biosensors has been developed. The so-called Simplex algorithm computes a minimum value for the difference between experimental and theoretical data. The latter consider a numerical model based on a ping-pong reaction mechanism corresponding to an oxidase enzyme that has been immobilized between diffusion membranes. The results obtained from the simulation of a first-generation lactate biosensor in presence of 0.1 mM substrate indicate that the concentration of O 2 would decrease only 0.1% with regards to its bulk value. Besides, the concentration of this natural mediator would remain practically unchanged during a typical calibration curve. This is because the rather high diffusion coefficient of O 2 and its regeneration at the electrode surface minimize the concentration changes of this species. In addition, it was found that the thicknesses of polycarbonate membranes and the enzymatic matrix have average values of 13 μm and 20 μm, respectively. However, these membranes might exhibit smaller thickness depending on the time provided for the crosslinking reaction. In this regard, if this reaction is slow enough, the enzymatic matrix would be able to diffuse through the pores of polycarbonate membranes and they will appear to be thinner than expected. This effect may compromise the response-time and the reproducibility of this kind of biosensors. |
| publishDate |
2012 |
| dc.date.none.fl_str_mv |
2012-11 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/113315 Romero, Marcelo Ricardo; Baruzzi, Ana Maria; Garay, Fernando Sebastian; How low does the oxygen concentration go within a sandwich-type amperometric biosensor?; Elsevier Science Sa; Sensors and Actuators B: Chemical; 174; 11-2012; 279-284 0925-4005 CONICET Digital CONICET |
| url |
http://hdl.handle.net/11336/113315 |
| identifier_str_mv |
Romero, Marcelo Ricardo; Baruzzi, Ana Maria; Garay, Fernando Sebastian; How low does the oxygen concentration go within a sandwich-type amperometric biosensor?; Elsevier Science Sa; Sensors and Actuators B: Chemical; 174; 11-2012; 279-284 0925-4005 CONICET Digital CONICET |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0925400512008416# info:eu-repo/semantics/altIdentifier/doi/10.1016/j.snb.2012.08.027 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| dc.format.none.fl_str_mv |
application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier Science Sa |
| publisher.none.fl_str_mv |
Elsevier Science Sa |
| dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
| reponame_str |
CONICET Digital (CONICET) |
| collection |
CONICET Digital (CONICET) |
| instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
| _version_ |
1847427302669942784 |
| score |
13.10058 |