Nanohybrids based on multi-walled carbon nanotubes and MOF-199: Advantages on the electrochemical reduction of hydrogen peroxide and sensing applications
- Autores
- Gallay, Pablo; Vaschetti, Virginia María; Aghemo, Facundo Daniel; Dalmasso, Pablo Roberto; Rivas, Gustavo Adolfo
- Año de publicación
- 2025
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- We report the advantages of a nanohybrid obtained through the integration of multi-walled carbon nanotubes (MWCNTs) and MOF-199 by sono-synthesis. The resulting nanohybrid presents important synergic effects on the catalytic reduction of hydrogen peroxide due to the facilitated regeneration of the catalytic center in the presence of the interconnected carbon nanomaterial. Glassy carbon electrodes (GCE) modified with this hybrid nanomaterial dispersed in Nafion allowed the sensitive quantification of hydrogen peroxide: linear range between 5.0 × 10-6 M and 7.5 × 10-5 M (R2 = 0.997), with a sensitivity of (128 ± 3) x 102 μA M-1, a detection limit of 2 μM, and a reproducibility of 8.0 % for the same nanohybrid and 5 different electrodes allowing the competitive electrochemical determination of hydrogen peroxide. The sensor was successfully used for the quantification of this important analyte in diverse commercial samples (milk, human serum, contact lens disinfecting solution, and mouthwash).
Fil: Gallay, Pablo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina
Fil: Vaschetti, Virginia María. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina. Universidad Tecnologica Nacional. Facultad Regional Cordoba. Departamento de Ingenieria Quimica. Centro de Investigacion y Transferencia En Ingenieria Quimica.; Argentina
Fil: Aghemo, Facundo Daniel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina. Universidad Tecnologica Nacional. Facultad Regional Cordoba. Departamento de Ingenieria Quimica. Centro de Investigacion y Transferencia En Ingenieria Quimica.; Argentina
Fil: Dalmasso, Pablo Roberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina. Universidad Tecnologica Nacional. Facultad Regional Cordoba. Departamento de Ingenieria Quimica. Centro de Investigacion y Transferencia En Ingenieria Quimica.; Argentina
Fil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina - Materia
-
MOF-199
HYBRID MATERIAL
CARBON NANOTUBES
HYDROGEN PEROXIDE
ELECTROCHEMICAL SENSOR - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/272042
Ver los metadatos del registro completo
id |
CONICETDig_641f85f5bfed20c15b9a01e1587c1052 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/272042 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Nanohybrids based on multi-walled carbon nanotubes and MOF-199: Advantages on the electrochemical reduction of hydrogen peroxide and sensing applicationsGallay, PabloVaschetti, Virginia MaríaAghemo, Facundo DanielDalmasso, Pablo RobertoRivas, Gustavo AdolfoMOF-199HYBRID MATERIALCARBON NANOTUBESHYDROGEN PEROXIDEELECTROCHEMICAL SENSORhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1We report the advantages of a nanohybrid obtained through the integration of multi-walled carbon nanotubes (MWCNTs) and MOF-199 by sono-synthesis. The resulting nanohybrid presents important synergic effects on the catalytic reduction of hydrogen peroxide due to the facilitated regeneration of the catalytic center in the presence of the interconnected carbon nanomaterial. Glassy carbon electrodes (GCE) modified with this hybrid nanomaterial dispersed in Nafion allowed the sensitive quantification of hydrogen peroxide: linear range between 5.0 × 10-6 M and 7.5 × 10-5 M (R2 = 0.997), with a sensitivity of (128 ± 3) x 102 μA M-1, a detection limit of 2 μM, and a reproducibility of 8.0 % for the same nanohybrid and 5 different electrodes allowing the competitive electrochemical determination of hydrogen peroxide. The sensor was successfully used for the quantification of this important analyte in diverse commercial samples (milk, human serum, contact lens disinfecting solution, and mouthwash).Fil: Gallay, Pablo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaFil: Vaschetti, Virginia María. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina. Universidad Tecnologica Nacional. Facultad Regional Cordoba. Departamento de Ingenieria Quimica. Centro de Investigacion y Transferencia En Ingenieria Quimica.; ArgentinaFil: Aghemo, Facundo Daniel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina. Universidad Tecnologica Nacional. Facultad Regional Cordoba. Departamento de Ingenieria Quimica. Centro de Investigacion y Transferencia En Ingenieria Quimica.; ArgentinaFil: Dalmasso, Pablo Roberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina. Universidad Tecnologica Nacional. Facultad Regional Cordoba. Departamento de Ingenieria Quimica. Centro de Investigacion y Transferencia En Ingenieria Quimica.; ArgentinaFil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; ArgentinaElsevier2025-06info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/272042Gallay, Pablo; Vaschetti, Virginia María; Aghemo, Facundo Daniel; Dalmasso, Pablo Roberto; Rivas, Gustavo Adolfo; Nanohybrids based on multi-walled carbon nanotubes and MOF-199: Advantages on the electrochemical reduction of hydrogen peroxide and sensing applications; Elsevier; Journal of Pharmaceutical and Biomedical Analysis Open; 5; 6-2025; 1-62949-771XCONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S2949771X25000179info:eu-repo/semantics/altIdentifier/doi/10.1016/j.jpbao.2025.100066info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T09:48:38Zoai:ri.conicet.gov.ar:11336/272042instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 09:48:38.802CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Nanohybrids based on multi-walled carbon nanotubes and MOF-199: Advantages on the electrochemical reduction of hydrogen peroxide and sensing applications |
title |
Nanohybrids based on multi-walled carbon nanotubes and MOF-199: Advantages on the electrochemical reduction of hydrogen peroxide and sensing applications |
spellingShingle |
Nanohybrids based on multi-walled carbon nanotubes and MOF-199: Advantages on the electrochemical reduction of hydrogen peroxide and sensing applications Gallay, Pablo MOF-199 HYBRID MATERIAL CARBON NANOTUBES HYDROGEN PEROXIDE ELECTROCHEMICAL SENSOR |
title_short |
Nanohybrids based on multi-walled carbon nanotubes and MOF-199: Advantages on the electrochemical reduction of hydrogen peroxide and sensing applications |
title_full |
Nanohybrids based on multi-walled carbon nanotubes and MOF-199: Advantages on the electrochemical reduction of hydrogen peroxide and sensing applications |
title_fullStr |
Nanohybrids based on multi-walled carbon nanotubes and MOF-199: Advantages on the electrochemical reduction of hydrogen peroxide and sensing applications |
title_full_unstemmed |
Nanohybrids based on multi-walled carbon nanotubes and MOF-199: Advantages on the electrochemical reduction of hydrogen peroxide and sensing applications |
title_sort |
Nanohybrids based on multi-walled carbon nanotubes and MOF-199: Advantages on the electrochemical reduction of hydrogen peroxide and sensing applications |
dc.creator.none.fl_str_mv |
Gallay, Pablo Vaschetti, Virginia María Aghemo, Facundo Daniel Dalmasso, Pablo Roberto Rivas, Gustavo Adolfo |
author |
Gallay, Pablo |
author_facet |
Gallay, Pablo Vaschetti, Virginia María Aghemo, Facundo Daniel Dalmasso, Pablo Roberto Rivas, Gustavo Adolfo |
author_role |
author |
author2 |
Vaschetti, Virginia María Aghemo, Facundo Daniel Dalmasso, Pablo Roberto Rivas, Gustavo Adolfo |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
MOF-199 HYBRID MATERIAL CARBON NANOTUBES HYDROGEN PEROXIDE ELECTROCHEMICAL SENSOR |
topic |
MOF-199 HYBRID MATERIAL CARBON NANOTUBES HYDROGEN PEROXIDE ELECTROCHEMICAL SENSOR |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
We report the advantages of a nanohybrid obtained through the integration of multi-walled carbon nanotubes (MWCNTs) and MOF-199 by sono-synthesis. The resulting nanohybrid presents important synergic effects on the catalytic reduction of hydrogen peroxide due to the facilitated regeneration of the catalytic center in the presence of the interconnected carbon nanomaterial. Glassy carbon electrodes (GCE) modified with this hybrid nanomaterial dispersed in Nafion allowed the sensitive quantification of hydrogen peroxide: linear range between 5.0 × 10-6 M and 7.5 × 10-5 M (R2 = 0.997), with a sensitivity of (128 ± 3) x 102 μA M-1, a detection limit of 2 μM, and a reproducibility of 8.0 % for the same nanohybrid and 5 different electrodes allowing the competitive electrochemical determination of hydrogen peroxide. The sensor was successfully used for the quantification of this important analyte in diverse commercial samples (milk, human serum, contact lens disinfecting solution, and mouthwash). Fil: Gallay, Pablo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina Fil: Vaschetti, Virginia María. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina. Universidad Tecnologica Nacional. Facultad Regional Cordoba. Departamento de Ingenieria Quimica. Centro de Investigacion y Transferencia En Ingenieria Quimica.; Argentina Fil: Aghemo, Facundo Daniel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina. Universidad Tecnologica Nacional. Facultad Regional Cordoba. Departamento de Ingenieria Quimica. Centro de Investigacion y Transferencia En Ingenieria Quimica.; Argentina Fil: Dalmasso, Pablo Roberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina. Universidad Tecnologica Nacional. Facultad Regional Cordoba. Departamento de Ingenieria Quimica. Centro de Investigacion y Transferencia En Ingenieria Quimica.; Argentina Fil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina |
description |
We report the advantages of a nanohybrid obtained through the integration of multi-walled carbon nanotubes (MWCNTs) and MOF-199 by sono-synthesis. The resulting nanohybrid presents important synergic effects on the catalytic reduction of hydrogen peroxide due to the facilitated regeneration of the catalytic center in the presence of the interconnected carbon nanomaterial. Glassy carbon electrodes (GCE) modified with this hybrid nanomaterial dispersed in Nafion allowed the sensitive quantification of hydrogen peroxide: linear range between 5.0 × 10-6 M and 7.5 × 10-5 M (R2 = 0.997), with a sensitivity of (128 ± 3) x 102 μA M-1, a detection limit of 2 μM, and a reproducibility of 8.0 % for the same nanohybrid and 5 different electrodes allowing the competitive electrochemical determination of hydrogen peroxide. The sensor was successfully used for the quantification of this important analyte in diverse commercial samples (milk, human serum, contact lens disinfecting solution, and mouthwash). |
publishDate |
2025 |
dc.date.none.fl_str_mv |
2025-06 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/272042 Gallay, Pablo; Vaschetti, Virginia María; Aghemo, Facundo Daniel; Dalmasso, Pablo Roberto; Rivas, Gustavo Adolfo; Nanohybrids based on multi-walled carbon nanotubes and MOF-199: Advantages on the electrochemical reduction of hydrogen peroxide and sensing applications; Elsevier; Journal of Pharmaceutical and Biomedical Analysis Open; 5; 6-2025; 1-6 2949-771X CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/272042 |
identifier_str_mv |
Gallay, Pablo; Vaschetti, Virginia María; Aghemo, Facundo Daniel; Dalmasso, Pablo Roberto; Rivas, Gustavo Adolfo; Nanohybrids based on multi-walled carbon nanotubes and MOF-199: Advantages on the electrochemical reduction of hydrogen peroxide and sensing applications; Elsevier; Journal of Pharmaceutical and Biomedical Analysis Open; 5; 6-2025; 1-6 2949-771X CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S2949771X25000179 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.jpbao.2025.100066 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844613509608898560 |
score |
13.070432 |