A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples

Autores
Savia, Caren Luciana; Osorio, Juliana Soledad; Rodriguez, Joaquin Valentin; Guibert, Edgardo Elvio; Rinaudo, Agustín
Año de publicación
2021
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Cervico-vaginal mucus (CVM) is a viscoelastic substance continuously produced by secretory cells of the endocervix and the vagina of cows. Its physicochemical composition varies depending on the hormonal status of the estrous cycle. In veterinary medicine refractometry is a widely diffused technique to determine total solids (TS) content of biological samples, but there are not published data of CVM total solids from refractometric measures. Refractometric TS determination contributes to the qualitative constituents analysis of CVM, additionally it is an easier and more inexpensive technique than gravimetric TS determination. The main goal of the present paper was to validate a refractometric method to estimate TS concentration of the soluble fraction of CVM samples. Samples were collected from seventy-three Holando Argentino cows of Santa Fe province farms in Argentina. Cows were classified in three experimental groups: healthy, subclinical (SE) and clinical endometritis (CE) group. To achieve a solubilisation protocol for CVM samples, four Triton™ X-100 concentrations were tested. Refractive index (RI) and gravimetric total solid (gTS) concentration of solubilised samples were determined for the three experimental groups. A mathematical equation was determined with the experimental data from the healthy group, in order to obtain calculated total solid concentration (cTS) from refractivity (R) values. To validate the RI method for CVM samples, cTS concentrations were compared with gTS concentrations from endometritis group samples. Triton™ X-100 0.01% (V/V) improved CVM samples handling and did not change physicochemical parameters (gTS, Na+ and K+ concentration, and RI values). The linear regression equation obtained was: cTS (g/dL) = (R – 0.67)/16.2, r2 = 0.91. Correlation between gTS and cTS concentration was: r = 0.97 for SE group and r = 0.97 for CE group. The homogenization protocol allowed the measurement of physicochemical parameters without altering their values. A high correlation coefficient between cTS and gTS postulates refractometry as an accurate method to determine TS concentration for solubilised CVM samples.
Fil: Savia, Caren Luciana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Facultad de Ciencias Veterinarias; Argentina
Fil: Osorio, Juliana Soledad. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; Argentina
Fil: Rodriguez, Joaquin Valentin. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; Argentina
Fil: Guibert, Edgardo Elvio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; Argentina
Fil: Rinaudo, Agustín. Universidad Nacional de Rosario. Facultad de Ciencias Veterinarias; Argentina
Materia
REFRACTOMETRÍA
SOLIDOS TOTALES
MUCUS
ENDOMETRITIS
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/153313

id CONICETDig_258a378f511f58888fbf98d5156091eb
oai_identifier_str oai:ri.conicet.gov.ar:11336/153313
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samplesSavia, Caren LucianaOsorio, Juliana SoledadRodriguez, Joaquin ValentinGuibert, Edgardo ElvioRinaudo, AgustínREFRACTOMETRÍASOLIDOS TOTALESMUCUSENDOMETRITIShttps://purl.org/becyt/ford/4.3https://purl.org/becyt/ford/4Cervico-vaginal mucus (CVM) is a viscoelastic substance continuously produced by secretory cells of the endocervix and the vagina of cows. Its physicochemical composition varies depending on the hormonal status of the estrous cycle. In veterinary medicine refractometry is a widely diffused technique to determine total solids (TS) content of biological samples, but there are not published data of CVM total solids from refractometric measures. Refractometric TS determination contributes to the qualitative constituents analysis of CVM, additionally it is an easier and more inexpensive technique than gravimetric TS determination. The main goal of the present paper was to validate a refractometric method to estimate TS concentration of the soluble fraction of CVM samples. Samples were collected from seventy-three Holando Argentino cows of Santa Fe province farms in Argentina. Cows were classified in three experimental groups: healthy, subclinical (SE) and clinical endometritis (CE) group. To achieve a solubilisation protocol for CVM samples, four Triton™ X-100 concentrations were tested. Refractive index (RI) and gravimetric total solid (gTS) concentration of solubilised samples were determined for the three experimental groups. A mathematical equation was determined with the experimental data from the healthy group, in order to obtain calculated total solid concentration (cTS) from refractivity (R) values. To validate the RI method for CVM samples, cTS concentrations were compared with gTS concentrations from endometritis group samples. Triton™ X-100 0.01% (V/V) improved CVM samples handling and did not change physicochemical parameters (gTS, Na+ and K+ concentration, and RI values). The linear regression equation obtained was: cTS (g/dL) = (R – 0.67)/16.2, r2 = 0.91. Correlation between gTS and cTS concentration was: r = 0.97 for SE group and r = 0.97 for CE group. The homogenization protocol allowed the measurement of physicochemical parameters without altering their values. A high correlation coefficient between cTS and gTS postulates refractometry as an accurate method to determine TS concentration for solubilised CVM samples.Fil: Savia, Caren Luciana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Facultad de Ciencias Veterinarias; ArgentinaFil: Osorio, Juliana Soledad. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; ArgentinaFil: Rodriguez, Joaquin Valentin. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; ArgentinaFil: Guibert, Edgardo Elvio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; ArgentinaFil: Rinaudo, Agustín. Universidad Nacional de Rosario. Facultad de Ciencias Veterinarias; ArgentinaElsevier2021-05info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/153313Savia, Caren Luciana; Osorio, Juliana Soledad; Rodriguez, Joaquin Valentin; Guibert, Edgardo Elvio; Rinaudo, Agustín; A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples; Elsevier; Heliyon; 7; 5; 5-2021; 1-62405-8440CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8131254/info:eu-repo/semantics/altIdentifier/url/https://www.cell.com/heliyon/fulltext/S2405-8440(21)01113-0info:eu-repo/semantics/altIdentifier/doi/10.1016/j.heliyon.2021.e07010info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-22T11:36:09Zoai:ri.conicet.gov.ar:11336/153313instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-22 11:36:09.299CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples
title A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples
spellingShingle A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples
Savia, Caren Luciana
REFRACTOMETRÍA
SOLIDOS TOTALES
MUCUS
ENDOMETRITIS
title_short A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples
title_full A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples
title_fullStr A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples
title_full_unstemmed A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples
title_sort A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples
dc.creator.none.fl_str_mv Savia, Caren Luciana
Osorio, Juliana Soledad
Rodriguez, Joaquin Valentin
Guibert, Edgardo Elvio
Rinaudo, Agustín
author Savia, Caren Luciana
author_facet Savia, Caren Luciana
Osorio, Juliana Soledad
Rodriguez, Joaquin Valentin
Guibert, Edgardo Elvio
Rinaudo, Agustín
author_role author
author2 Osorio, Juliana Soledad
Rodriguez, Joaquin Valentin
Guibert, Edgardo Elvio
Rinaudo, Agustín
author2_role author
author
author
author
dc.subject.none.fl_str_mv REFRACTOMETRÍA
SOLIDOS TOTALES
MUCUS
ENDOMETRITIS
topic REFRACTOMETRÍA
SOLIDOS TOTALES
MUCUS
ENDOMETRITIS
purl_subject.fl_str_mv https://purl.org/becyt/ford/4.3
https://purl.org/becyt/ford/4
dc.description.none.fl_txt_mv Cervico-vaginal mucus (CVM) is a viscoelastic substance continuously produced by secretory cells of the endocervix and the vagina of cows. Its physicochemical composition varies depending on the hormonal status of the estrous cycle. In veterinary medicine refractometry is a widely diffused technique to determine total solids (TS) content of biological samples, but there are not published data of CVM total solids from refractometric measures. Refractometric TS determination contributes to the qualitative constituents analysis of CVM, additionally it is an easier and more inexpensive technique than gravimetric TS determination. The main goal of the present paper was to validate a refractometric method to estimate TS concentration of the soluble fraction of CVM samples. Samples were collected from seventy-three Holando Argentino cows of Santa Fe province farms in Argentina. Cows were classified in three experimental groups: healthy, subclinical (SE) and clinical endometritis (CE) group. To achieve a solubilisation protocol for CVM samples, four Triton™ X-100 concentrations were tested. Refractive index (RI) and gravimetric total solid (gTS) concentration of solubilised samples were determined for the three experimental groups. A mathematical equation was determined with the experimental data from the healthy group, in order to obtain calculated total solid concentration (cTS) from refractivity (R) values. To validate the RI method for CVM samples, cTS concentrations were compared with gTS concentrations from endometritis group samples. Triton™ X-100 0.01% (V/V) improved CVM samples handling and did not change physicochemical parameters (gTS, Na+ and K+ concentration, and RI values). The linear regression equation obtained was: cTS (g/dL) = (R – 0.67)/16.2, r2 = 0.91. Correlation between gTS and cTS concentration was: r = 0.97 for SE group and r = 0.97 for CE group. The homogenization protocol allowed the measurement of physicochemical parameters without altering their values. A high correlation coefficient between cTS and gTS postulates refractometry as an accurate method to determine TS concentration for solubilised CVM samples.
Fil: Savia, Caren Luciana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Facultad de Ciencias Veterinarias; Argentina
Fil: Osorio, Juliana Soledad. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; Argentina
Fil: Rodriguez, Joaquin Valentin. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; Argentina
Fil: Guibert, Edgardo Elvio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; Argentina
Fil: Rinaudo, Agustín. Universidad Nacional de Rosario. Facultad de Ciencias Veterinarias; Argentina
description Cervico-vaginal mucus (CVM) is a viscoelastic substance continuously produced by secretory cells of the endocervix and the vagina of cows. Its physicochemical composition varies depending on the hormonal status of the estrous cycle. In veterinary medicine refractometry is a widely diffused technique to determine total solids (TS) content of biological samples, but there are not published data of CVM total solids from refractometric measures. Refractometric TS determination contributes to the qualitative constituents analysis of CVM, additionally it is an easier and more inexpensive technique than gravimetric TS determination. The main goal of the present paper was to validate a refractometric method to estimate TS concentration of the soluble fraction of CVM samples. Samples were collected from seventy-three Holando Argentino cows of Santa Fe province farms in Argentina. Cows were classified in three experimental groups: healthy, subclinical (SE) and clinical endometritis (CE) group. To achieve a solubilisation protocol for CVM samples, four Triton™ X-100 concentrations were tested. Refractive index (RI) and gravimetric total solid (gTS) concentration of solubilised samples were determined for the three experimental groups. A mathematical equation was determined with the experimental data from the healthy group, in order to obtain calculated total solid concentration (cTS) from refractivity (R) values. To validate the RI method for CVM samples, cTS concentrations were compared with gTS concentrations from endometritis group samples. Triton™ X-100 0.01% (V/V) improved CVM samples handling and did not change physicochemical parameters (gTS, Na+ and K+ concentration, and RI values). The linear regression equation obtained was: cTS (g/dL) = (R – 0.67)/16.2, r2 = 0.91. Correlation between gTS and cTS concentration was: r = 0.97 for SE group and r = 0.97 for CE group. The homogenization protocol allowed the measurement of physicochemical parameters without altering their values. A high correlation coefficient between cTS and gTS postulates refractometry as an accurate method to determine TS concentration for solubilised CVM samples.
publishDate 2021
dc.date.none.fl_str_mv 2021-05
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/153313
Savia, Caren Luciana; Osorio, Juliana Soledad; Rodriguez, Joaquin Valentin; Guibert, Edgardo Elvio; Rinaudo, Agustín; A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples; Elsevier; Heliyon; 7; 5; 5-2021; 1-6
2405-8440
CONICET Digital
CONICET
url http://hdl.handle.net/11336/153313
identifier_str_mv Savia, Caren Luciana; Osorio, Juliana Soledad; Rodriguez, Joaquin Valentin; Guibert, Edgardo Elvio; Rinaudo, Agustín; A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples; Elsevier; Heliyon; 7; 5; 5-2021; 1-6
2405-8440
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8131254/
info:eu-repo/semantics/altIdentifier/url/https://www.cell.com/heliyon/fulltext/S2405-8440(21)01113-0
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.heliyon.2021.e07010
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1846782000560603136
score 12.982451