A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples
- Autores
- Savia, Caren Luciana; Osorio, Juliana Soledad; Rodriguez, Joaquin Valentin; Guibert, Edgardo Elvio; Rinaudo, Agustín
- Año de publicación
- 2021
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Cervico-vaginal mucus (CVM) is a viscoelastic substance continuously produced by secretory cells of the endocervix and the vagina of cows. Its physicochemical composition varies depending on the hormonal status of the estrous cycle. In veterinary medicine refractometry is a widely diffused technique to determine total solids (TS) content of biological samples, but there are not published data of CVM total solids from refractometric measures. Refractometric TS determination contributes to the qualitative constituents analysis of CVM, additionally it is an easier and more inexpensive technique than gravimetric TS determination. The main goal of the present paper was to validate a refractometric method to estimate TS concentration of the soluble fraction of CVM samples. Samples were collected from seventy-three Holando Argentino cows of Santa Fe province farms in Argentina. Cows were classified in three experimental groups: healthy, subclinical (SE) and clinical endometritis (CE) group. To achieve a solubilisation protocol for CVM samples, four Triton™ X-100 concentrations were tested. Refractive index (RI) and gravimetric total solid (gTS) concentration of solubilised samples were determined for the three experimental groups. A mathematical equation was determined with the experimental data from the healthy group, in order to obtain calculated total solid concentration (cTS) from refractivity (R) values. To validate the RI method for CVM samples, cTS concentrations were compared with gTS concentrations from endometritis group samples. Triton™ X-100 0.01% (V/V) improved CVM samples handling and did not change physicochemical parameters (gTS, Na+ and K+ concentration, and RI values). The linear regression equation obtained was: cTS (g/dL) = (R – 0.67)/16.2, r2 = 0.91. Correlation between gTS and cTS concentration was: r = 0.97 for SE group and r = 0.97 for CE group. The homogenization protocol allowed the measurement of physicochemical parameters without altering their values. A high correlation coefficient between cTS and gTS postulates refractometry as an accurate method to determine TS concentration for solubilised CVM samples.
Fil: Savia, Caren Luciana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Facultad de Ciencias Veterinarias; Argentina
Fil: Osorio, Juliana Soledad. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; Argentina
Fil: Rodriguez, Joaquin Valentin. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; Argentina
Fil: Guibert, Edgardo Elvio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; Argentina
Fil: Rinaudo, Agustín. Universidad Nacional de Rosario. Facultad de Ciencias Veterinarias; Argentina - Materia
-
REFRACTOMETRÍA
SOLIDOS TOTALES
MUCUS
ENDOMETRITIS - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
- Repositorio
.jpg)
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/153313
Ver los metadatos del registro completo
| id |
CONICETDig_258a378f511f58888fbf98d5156091eb |
|---|---|
| oai_identifier_str |
oai:ri.conicet.gov.ar:11336/153313 |
| network_acronym_str |
CONICETDig |
| repository_id_str |
3498 |
| network_name_str |
CONICET Digital (CONICET) |
| spelling |
A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samplesSavia, Caren LucianaOsorio, Juliana SoledadRodriguez, Joaquin ValentinGuibert, Edgardo ElvioRinaudo, AgustínREFRACTOMETRÍASOLIDOS TOTALESMUCUSENDOMETRITIShttps://purl.org/becyt/ford/4.3https://purl.org/becyt/ford/4Cervico-vaginal mucus (CVM) is a viscoelastic substance continuously produced by secretory cells of the endocervix and the vagina of cows. Its physicochemical composition varies depending on the hormonal status of the estrous cycle. In veterinary medicine refractometry is a widely diffused technique to determine total solids (TS) content of biological samples, but there are not published data of CVM total solids from refractometric measures. Refractometric TS determination contributes to the qualitative constituents analysis of CVM, additionally it is an easier and more inexpensive technique than gravimetric TS determination. The main goal of the present paper was to validate a refractometric method to estimate TS concentration of the soluble fraction of CVM samples. Samples were collected from seventy-three Holando Argentino cows of Santa Fe province farms in Argentina. Cows were classified in three experimental groups: healthy, subclinical (SE) and clinical endometritis (CE) group. To achieve a solubilisation protocol for CVM samples, four Triton™ X-100 concentrations were tested. Refractive index (RI) and gravimetric total solid (gTS) concentration of solubilised samples were determined for the three experimental groups. A mathematical equation was determined with the experimental data from the healthy group, in order to obtain calculated total solid concentration (cTS) from refractivity (R) values. To validate the RI method for CVM samples, cTS concentrations were compared with gTS concentrations from endometritis group samples. Triton™ X-100 0.01% (V/V) improved CVM samples handling and did not change physicochemical parameters (gTS, Na+ and K+ concentration, and RI values). The linear regression equation obtained was: cTS (g/dL) = (R – 0.67)/16.2, r2 = 0.91. Correlation between gTS and cTS concentration was: r = 0.97 for SE group and r = 0.97 for CE group. The homogenization protocol allowed the measurement of physicochemical parameters without altering their values. A high correlation coefficient between cTS and gTS postulates refractometry as an accurate method to determine TS concentration for solubilised CVM samples.Fil: Savia, Caren Luciana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Facultad de Ciencias Veterinarias; ArgentinaFil: Osorio, Juliana Soledad. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; ArgentinaFil: Rodriguez, Joaquin Valentin. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; ArgentinaFil: Guibert, Edgardo Elvio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; ArgentinaFil: Rinaudo, Agustín. Universidad Nacional de Rosario. Facultad de Ciencias Veterinarias; ArgentinaElsevier2021-05info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/153313Savia, Caren Luciana; Osorio, Juliana Soledad; Rodriguez, Joaquin Valentin; Guibert, Edgardo Elvio; Rinaudo, Agustín; A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples; Elsevier; Heliyon; 7; 5; 5-2021; 1-62405-8440CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8131254/info:eu-repo/semantics/altIdentifier/url/https://www.cell.com/heliyon/fulltext/S2405-8440(21)01113-0info:eu-repo/semantics/altIdentifier/doi/10.1016/j.heliyon.2021.e07010info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-22T11:36:09Zoai:ri.conicet.gov.ar:11336/153313instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-22 11:36:09.299CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
| dc.title.none.fl_str_mv |
A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples |
| title |
A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples |
| spellingShingle |
A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples Savia, Caren Luciana REFRACTOMETRÍA SOLIDOS TOTALES MUCUS ENDOMETRITIS |
| title_short |
A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples |
| title_full |
A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples |
| title_fullStr |
A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples |
| title_full_unstemmed |
A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples |
| title_sort |
A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples |
| dc.creator.none.fl_str_mv |
Savia, Caren Luciana Osorio, Juliana Soledad Rodriguez, Joaquin Valentin Guibert, Edgardo Elvio Rinaudo, Agustín |
| author |
Savia, Caren Luciana |
| author_facet |
Savia, Caren Luciana Osorio, Juliana Soledad Rodriguez, Joaquin Valentin Guibert, Edgardo Elvio Rinaudo, Agustín |
| author_role |
author |
| author2 |
Osorio, Juliana Soledad Rodriguez, Joaquin Valentin Guibert, Edgardo Elvio Rinaudo, Agustín |
| author2_role |
author author author author |
| dc.subject.none.fl_str_mv |
REFRACTOMETRÍA SOLIDOS TOTALES MUCUS ENDOMETRITIS |
| topic |
REFRACTOMETRÍA SOLIDOS TOTALES MUCUS ENDOMETRITIS |
| purl_subject.fl_str_mv |
https://purl.org/becyt/ford/4.3 https://purl.org/becyt/ford/4 |
| dc.description.none.fl_txt_mv |
Cervico-vaginal mucus (CVM) is a viscoelastic substance continuously produced by secretory cells of the endocervix and the vagina of cows. Its physicochemical composition varies depending on the hormonal status of the estrous cycle. In veterinary medicine refractometry is a widely diffused technique to determine total solids (TS) content of biological samples, but there are not published data of CVM total solids from refractometric measures. Refractometric TS determination contributes to the qualitative constituents analysis of CVM, additionally it is an easier and more inexpensive technique than gravimetric TS determination. The main goal of the present paper was to validate a refractometric method to estimate TS concentration of the soluble fraction of CVM samples. Samples were collected from seventy-three Holando Argentino cows of Santa Fe province farms in Argentina. Cows were classified in three experimental groups: healthy, subclinical (SE) and clinical endometritis (CE) group. To achieve a solubilisation protocol for CVM samples, four Triton™ X-100 concentrations were tested. Refractive index (RI) and gravimetric total solid (gTS) concentration of solubilised samples were determined for the three experimental groups. A mathematical equation was determined with the experimental data from the healthy group, in order to obtain calculated total solid concentration (cTS) from refractivity (R) values. To validate the RI method for CVM samples, cTS concentrations were compared with gTS concentrations from endometritis group samples. Triton™ X-100 0.01% (V/V) improved CVM samples handling and did not change physicochemical parameters (gTS, Na+ and K+ concentration, and RI values). The linear regression equation obtained was: cTS (g/dL) = (R – 0.67)/16.2, r2 = 0.91. Correlation between gTS and cTS concentration was: r = 0.97 for SE group and r = 0.97 for CE group. The homogenization protocol allowed the measurement of physicochemical parameters without altering their values. A high correlation coefficient between cTS and gTS postulates refractometry as an accurate method to determine TS concentration for solubilised CVM samples. Fil: Savia, Caren Luciana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Facultad de Ciencias Veterinarias; Argentina Fil: Osorio, Juliana Soledad. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; Argentina Fil: Rodriguez, Joaquin Valentin. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; Argentina Fil: Guibert, Edgardo Elvio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario; Argentina. Universidad Nacional de Rosario. Secretaria de Ciencia y Técnica. Centro Binacional de Investigación en Criobiología Clínica y Aplicada; Argentina Fil: Rinaudo, Agustín. Universidad Nacional de Rosario. Facultad de Ciencias Veterinarias; Argentina |
| description |
Cervico-vaginal mucus (CVM) is a viscoelastic substance continuously produced by secretory cells of the endocervix and the vagina of cows. Its physicochemical composition varies depending on the hormonal status of the estrous cycle. In veterinary medicine refractometry is a widely diffused technique to determine total solids (TS) content of biological samples, but there are not published data of CVM total solids from refractometric measures. Refractometric TS determination contributes to the qualitative constituents analysis of CVM, additionally it is an easier and more inexpensive technique than gravimetric TS determination. The main goal of the present paper was to validate a refractometric method to estimate TS concentration of the soluble fraction of CVM samples. Samples were collected from seventy-three Holando Argentino cows of Santa Fe province farms in Argentina. Cows were classified in three experimental groups: healthy, subclinical (SE) and clinical endometritis (CE) group. To achieve a solubilisation protocol for CVM samples, four Triton™ X-100 concentrations were tested. Refractive index (RI) and gravimetric total solid (gTS) concentration of solubilised samples were determined for the three experimental groups. A mathematical equation was determined with the experimental data from the healthy group, in order to obtain calculated total solid concentration (cTS) from refractivity (R) values. To validate the RI method for CVM samples, cTS concentrations were compared with gTS concentrations from endometritis group samples. Triton™ X-100 0.01% (V/V) improved CVM samples handling and did not change physicochemical parameters (gTS, Na+ and K+ concentration, and RI values). The linear regression equation obtained was: cTS (g/dL) = (R – 0.67)/16.2, r2 = 0.91. Correlation between gTS and cTS concentration was: r = 0.97 for SE group and r = 0.97 for CE group. The homogenization protocol allowed the measurement of physicochemical parameters without altering their values. A high correlation coefficient between cTS and gTS postulates refractometry as an accurate method to determine TS concentration for solubilised CVM samples. |
| publishDate |
2021 |
| dc.date.none.fl_str_mv |
2021-05 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/153313 Savia, Caren Luciana; Osorio, Juliana Soledad; Rodriguez, Joaquin Valentin; Guibert, Edgardo Elvio; Rinaudo, Agustín; A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples; Elsevier; Heliyon; 7; 5; 5-2021; 1-6 2405-8440 CONICET Digital CONICET |
| url |
http://hdl.handle.net/11336/153313 |
| identifier_str_mv |
Savia, Caren Luciana; Osorio, Juliana Soledad; Rodriguez, Joaquin Valentin; Guibert, Edgardo Elvio; Rinaudo, Agustín; A simple and reliable refractometric method to determine the total solids concentration of the cervico-vaginal bovine mucus samples; Elsevier; Heliyon; 7; 5; 5-2021; 1-6 2405-8440 CONICET Digital CONICET |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8131254/ info:eu-repo/semantics/altIdentifier/url/https://www.cell.com/heliyon/fulltext/S2405-8440(21)01113-0 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.heliyon.2021.e07010 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
| dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier |
| publisher.none.fl_str_mv |
Elsevier |
| dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
| reponame_str |
CONICET Digital (CONICET) |
| collection |
CONICET Digital (CONICET) |
| instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
| _version_ |
1846782000560603136 |
| score |
12.982451 |