Preparation of Pipettes and Pipette-Filling Devices for Patch-Clamping Drosophila Neurons
- Autores
- Fernandez Chiappe, Florencia; Muraro, Nara Ines
- Año de publicación
- 2022
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- An essential requirement of every laboratory procedure is to have all materials ready when they are needed, so that the experimental flow is not disrupted. This is particularly true for patch clamping; therefore, effort must be devoted in advance to produce materials such as patch pipettes. This can be a fiddly business; hence, this protocol provides step-by-step advice on how to pull and polish patch-clamp pipettes. It also includes a brief description on how to prepare homemade filling devices to deliver saline efficiently and inexpensively into the pipettes. The protocol ends with guidelines on how to change the filament of a Sutter horizontal puller, a dreaded yet necessary activity that should be learned by anyone who wishes to become an expert patch clamper.
Fil: Fernandez Chiappe, Florencia. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Investigación en Biomedicina de Buenos Aires - Instituto Partner de la Sociedad Max Planck; Argentina
Fil: Muraro, Nara Ines. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Investigación en Biomedicina de Buenos Aires - Instituto Partner de la Sociedad Max Planck; Argentina - Materia
-
DROSOPHILA MELANOGASTER
ELECTROPHYSIOLOGY
PATCH-CLAMP
DISSECTION - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/215594
Ver los metadatos del registro completo
id |
CONICETDig_15fb8e305a2203b3a917c198a20cc984 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/215594 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Preparation of Pipettes and Pipette-Filling Devices for Patch-Clamping Drosophila NeuronsFernandez Chiappe, FlorenciaMuraro, Nara InesDROSOPHILA MELANOGASTERELECTROPHYSIOLOGYPATCH-CLAMPDISSECTIONhttps://purl.org/becyt/ford/1.6https://purl.org/becyt/ford/1An essential requirement of every laboratory procedure is to have all materials ready when they are needed, so that the experimental flow is not disrupted. This is particularly true for patch clamping; therefore, effort must be devoted in advance to produce materials such as patch pipettes. This can be a fiddly business; hence, this protocol provides step-by-step advice on how to pull and polish patch-clamp pipettes. It also includes a brief description on how to prepare homemade filling devices to deliver saline efficiently and inexpensively into the pipettes. The protocol ends with guidelines on how to change the filament of a Sutter horizontal puller, a dreaded yet necessary activity that should be learned by anyone who wishes to become an expert patch clamper.Fil: Fernandez Chiappe, Florencia. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Investigación en Biomedicina de Buenos Aires - Instituto Partner de la Sociedad Max Planck; ArgentinaFil: Muraro, Nara Ines. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Investigación en Biomedicina de Buenos Aires - Instituto Partner de la Sociedad Max Planck; ArgentinaCold Spring Harbor Laboratory Press2022-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/215594Fernandez Chiappe, Florencia; Muraro, Nara Ines; Preparation of Pipettes and Pipette-Filling Devices for Patch-Clamping Drosophila Neurons; Cold Spring Harbor Laboratory Press; Cold Spring Harbor Protocols; 2022; 8; 8-2022; 372-3781940-34021559-6095CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://cshprotocols.cshlp.org/content/2022/8/pdb.prot107932.longinfo:eu-repo/semantics/altIdentifier/doi/10.1101/pdb.prot107932info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:20:18Zoai:ri.conicet.gov.ar:11336/215594instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:20:18.694CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Preparation of Pipettes and Pipette-Filling Devices for Patch-Clamping Drosophila Neurons |
title |
Preparation of Pipettes and Pipette-Filling Devices for Patch-Clamping Drosophila Neurons |
spellingShingle |
Preparation of Pipettes and Pipette-Filling Devices for Patch-Clamping Drosophila Neurons Fernandez Chiappe, Florencia DROSOPHILA MELANOGASTER ELECTROPHYSIOLOGY PATCH-CLAMP DISSECTION |
title_short |
Preparation of Pipettes and Pipette-Filling Devices for Patch-Clamping Drosophila Neurons |
title_full |
Preparation of Pipettes and Pipette-Filling Devices for Patch-Clamping Drosophila Neurons |
title_fullStr |
Preparation of Pipettes and Pipette-Filling Devices for Patch-Clamping Drosophila Neurons |
title_full_unstemmed |
Preparation of Pipettes and Pipette-Filling Devices for Patch-Clamping Drosophila Neurons |
title_sort |
Preparation of Pipettes and Pipette-Filling Devices for Patch-Clamping Drosophila Neurons |
dc.creator.none.fl_str_mv |
Fernandez Chiappe, Florencia Muraro, Nara Ines |
author |
Fernandez Chiappe, Florencia |
author_facet |
Fernandez Chiappe, Florencia Muraro, Nara Ines |
author_role |
author |
author2 |
Muraro, Nara Ines |
author2_role |
author |
dc.subject.none.fl_str_mv |
DROSOPHILA MELANOGASTER ELECTROPHYSIOLOGY PATCH-CLAMP DISSECTION |
topic |
DROSOPHILA MELANOGASTER ELECTROPHYSIOLOGY PATCH-CLAMP DISSECTION |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.6 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
An essential requirement of every laboratory procedure is to have all materials ready when they are needed, so that the experimental flow is not disrupted. This is particularly true for patch clamping; therefore, effort must be devoted in advance to produce materials such as patch pipettes. This can be a fiddly business; hence, this protocol provides step-by-step advice on how to pull and polish patch-clamp pipettes. It also includes a brief description on how to prepare homemade filling devices to deliver saline efficiently and inexpensively into the pipettes. The protocol ends with guidelines on how to change the filament of a Sutter horizontal puller, a dreaded yet necessary activity that should be learned by anyone who wishes to become an expert patch clamper. Fil: Fernandez Chiappe, Florencia. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Investigación en Biomedicina de Buenos Aires - Instituto Partner de la Sociedad Max Planck; Argentina Fil: Muraro, Nara Ines. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Investigación en Biomedicina de Buenos Aires - Instituto Partner de la Sociedad Max Planck; Argentina |
description |
An essential requirement of every laboratory procedure is to have all materials ready when they are needed, so that the experimental flow is not disrupted. This is particularly true for patch clamping; therefore, effort must be devoted in advance to produce materials such as patch pipettes. This can be a fiddly business; hence, this protocol provides step-by-step advice on how to pull and polish patch-clamp pipettes. It also includes a brief description on how to prepare homemade filling devices to deliver saline efficiently and inexpensively into the pipettes. The protocol ends with guidelines on how to change the filament of a Sutter horizontal puller, a dreaded yet necessary activity that should be learned by anyone who wishes to become an expert patch clamper. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-08 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/215594 Fernandez Chiappe, Florencia; Muraro, Nara Ines; Preparation of Pipettes and Pipette-Filling Devices for Patch-Clamping Drosophila Neurons; Cold Spring Harbor Laboratory Press; Cold Spring Harbor Protocols; 2022; 8; 8-2022; 372-378 1940-3402 1559-6095 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/215594 |
identifier_str_mv |
Fernandez Chiappe, Florencia; Muraro, Nara Ines; Preparation of Pipettes and Pipette-Filling Devices for Patch-Clamping Drosophila Neurons; Cold Spring Harbor Laboratory Press; Cold Spring Harbor Protocols; 2022; 8; 8-2022; 372-378 1940-3402 1559-6095 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/http://cshprotocols.cshlp.org/content/2022/8/pdb.prot107932.long info:eu-repo/semantics/altIdentifier/doi/10.1101/pdb.prot107932 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Cold Spring Harbor Laboratory Press |
publisher.none.fl_str_mv |
Cold Spring Harbor Laboratory Press |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844614181913886720 |
score |
13.070432 |