Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm
- Autores
- Grunhut, Marcos; Centurión, María Eugenia; Fragoso, Wallace D.; Almeida, Luciano F.; de Araújo, Mário C.U.; Fernández Band, Beatriz Susana
- Año de publicación
- 2008
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- An enzymatic flow-batch system with spectrophotometric detection was developed for simultaneous determination of levodopa [(S)-2 amino-3-(3,4-dihydroxyphenyl)propionic acid] and carbidopa [(S)-3-(3,4-dihydroxyphenyl)-2-hydrazino-2-methylpropionic acid] in pharmaceutical preparations. The data were analysed by univariate method, partial least squares (PLS) and a novel variable selection for multiple lineal regression (MLR), the successive projections algorithm (SPA). The enzyme polyphenol oxidase (PPO; EC 1.14.18.1) obtained from Ipomoea batatas (L.) Lam. was used to oxidize both analytes to their respective dopaquinones, which presented a strong absorption between 295 and 540 nm. The statistical parameters (RMSE and correlation coefficient) calculated after the PLS in the spectral region between 295 and 540 nm and MLR-SPA application were appropriate for levodopa and carbidopa. A comparative study of univariate, PLS, in different ranges, and MLR-SPA chemometrics models, was carried out by applying the elliptical joint confidence region (EJCR) test. The results were satisfactory for PLS in the spectral region between 295 and 540 nm and for MLR-SPA. Tablets of commercial samples were analysed and the results obtained are in close agreement with both, spectrophotometric and HPLC pharmacopeia methods. The sample throughput was 18 h-1.
Fil: Grunhut, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina
Fil: Centurión, María Eugenia. Universidad Nacional del Sur. Departamento de Química; Argentina
Fil: Fragoso, Wallace D.. Universidade Federal da Paraíba; Brasil
Fil: Almeida, Luciano F.. Universidade Federal da Paraíba; Brasil
Fil: de Araújo, Mário C.U.. Universidade Federal da Paraíba; Brasil
Fil: Fernández Band, Beatriz Susana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina - Materia
-
CARBIDOPA
FLOW-BATCH
LEVODOPA
MLR-SPA
PLS
POLYPHENOL OXIDASE - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/95144
Ver los metadatos del registro completo
id |
CONICETDig_15c560be7c2d8a41ff26272925907ddc |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/95144 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithmGrunhut, MarcosCenturión, María EugeniaFragoso, Wallace D.Almeida, Luciano F.de Araújo, Mário C.U.Fernández Band, Beatriz SusanaCARBIDOPAFLOW-BATCHLEVODOPAMLR-SPAPLSPOLYPHENOL OXIDASEhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1An enzymatic flow-batch system with spectrophotometric detection was developed for simultaneous determination of levodopa [(S)-2 amino-3-(3,4-dihydroxyphenyl)propionic acid] and carbidopa [(S)-3-(3,4-dihydroxyphenyl)-2-hydrazino-2-methylpropionic acid] in pharmaceutical preparations. The data were analysed by univariate method, partial least squares (PLS) and a novel variable selection for multiple lineal regression (MLR), the successive projections algorithm (SPA). The enzyme polyphenol oxidase (PPO; EC 1.14.18.1) obtained from Ipomoea batatas (L.) Lam. was used to oxidize both analytes to their respective dopaquinones, which presented a strong absorption between 295 and 540 nm. The statistical parameters (RMSE and correlation coefficient) calculated after the PLS in the spectral region between 295 and 540 nm and MLR-SPA application were appropriate for levodopa and carbidopa. A comparative study of univariate, PLS, in different ranges, and MLR-SPA chemometrics models, was carried out by applying the elliptical joint confidence region (EJCR) test. The results were satisfactory for PLS in the spectral region between 295 and 540 nm and for MLR-SPA. Tablets of commercial samples were analysed and the results obtained are in close agreement with both, spectrophotometric and HPLC pharmacopeia methods. The sample throughput was 18 h-1.Fil: Grunhut, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; ArgentinaFil: Centurión, María Eugenia. Universidad Nacional del Sur. Departamento de Química; ArgentinaFil: Fragoso, Wallace D.. Universidade Federal da Paraíba; BrasilFil: Almeida, Luciano F.. Universidade Federal da Paraíba; BrasilFil: de Araújo, Mário C.U.. Universidade Federal da Paraíba; BrasilFil: Fernández Band, Beatriz Susana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; ArgentinaElsevier Science2008-05info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/95144Grunhut, Marcos; Centurión, María Eugenia; Fragoso, Wallace D.; Almeida, Luciano F.; de Araújo, Mário C.U.; et al.; Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm; Elsevier Science; Talanta; 75; 4; 5-2008; 950-9580039-9140CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0039914007008879info:eu-repo/semantics/altIdentifier/doi/10.1016/j.talanta.2007.12.029info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-15T15:40:18Zoai:ri.conicet.gov.ar:11336/95144instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-15 15:40:19.225CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm |
title |
Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm |
spellingShingle |
Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm Grunhut, Marcos CARBIDOPA FLOW-BATCH LEVODOPA MLR-SPA PLS POLYPHENOL OXIDASE |
title_short |
Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm |
title_full |
Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm |
title_fullStr |
Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm |
title_full_unstemmed |
Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm |
title_sort |
Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm |
dc.creator.none.fl_str_mv |
Grunhut, Marcos Centurión, María Eugenia Fragoso, Wallace D. Almeida, Luciano F. de Araújo, Mário C.U. Fernández Band, Beatriz Susana |
author |
Grunhut, Marcos |
author_facet |
Grunhut, Marcos Centurión, María Eugenia Fragoso, Wallace D. Almeida, Luciano F. de Araújo, Mário C.U. Fernández Band, Beatriz Susana |
author_role |
author |
author2 |
Centurión, María Eugenia Fragoso, Wallace D. Almeida, Luciano F. de Araújo, Mário C.U. Fernández Band, Beatriz Susana |
author2_role |
author author author author author |
dc.subject.none.fl_str_mv |
CARBIDOPA FLOW-BATCH LEVODOPA MLR-SPA PLS POLYPHENOL OXIDASE |
topic |
CARBIDOPA FLOW-BATCH LEVODOPA MLR-SPA PLS POLYPHENOL OXIDASE |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
An enzymatic flow-batch system with spectrophotometric detection was developed for simultaneous determination of levodopa [(S)-2 amino-3-(3,4-dihydroxyphenyl)propionic acid] and carbidopa [(S)-3-(3,4-dihydroxyphenyl)-2-hydrazino-2-methylpropionic acid] in pharmaceutical preparations. The data were analysed by univariate method, partial least squares (PLS) and a novel variable selection for multiple lineal regression (MLR), the successive projections algorithm (SPA). The enzyme polyphenol oxidase (PPO; EC 1.14.18.1) obtained from Ipomoea batatas (L.) Lam. was used to oxidize both analytes to their respective dopaquinones, which presented a strong absorption between 295 and 540 nm. The statistical parameters (RMSE and correlation coefficient) calculated after the PLS in the spectral region between 295 and 540 nm and MLR-SPA application were appropriate for levodopa and carbidopa. A comparative study of univariate, PLS, in different ranges, and MLR-SPA chemometrics models, was carried out by applying the elliptical joint confidence region (EJCR) test. The results were satisfactory for PLS in the spectral region between 295 and 540 nm and for MLR-SPA. Tablets of commercial samples were analysed and the results obtained are in close agreement with both, spectrophotometric and HPLC pharmacopeia methods. The sample throughput was 18 h-1. Fil: Grunhut, Marcos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina Fil: Centurión, María Eugenia. Universidad Nacional del Sur. Departamento de Química; Argentina Fil: Fragoso, Wallace D.. Universidade Federal da Paraíba; Brasil Fil: Almeida, Luciano F.. Universidade Federal da Paraíba; Brasil Fil: de Araújo, Mário C.U.. Universidade Federal da Paraíba; Brasil Fil: Fernández Band, Beatriz Susana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Química del Sur. Universidad Nacional del Sur. Departamento de Química. Instituto de Química del Sur; Argentina |
description |
An enzymatic flow-batch system with spectrophotometric detection was developed for simultaneous determination of levodopa [(S)-2 amino-3-(3,4-dihydroxyphenyl)propionic acid] and carbidopa [(S)-3-(3,4-dihydroxyphenyl)-2-hydrazino-2-methylpropionic acid] in pharmaceutical preparations. The data were analysed by univariate method, partial least squares (PLS) and a novel variable selection for multiple lineal regression (MLR), the successive projections algorithm (SPA). The enzyme polyphenol oxidase (PPO; EC 1.14.18.1) obtained from Ipomoea batatas (L.) Lam. was used to oxidize both analytes to their respective dopaquinones, which presented a strong absorption between 295 and 540 nm. The statistical parameters (RMSE and correlation coefficient) calculated after the PLS in the spectral region between 295 and 540 nm and MLR-SPA application were appropriate for levodopa and carbidopa. A comparative study of univariate, PLS, in different ranges, and MLR-SPA chemometrics models, was carried out by applying the elliptical joint confidence region (EJCR) test. The results were satisfactory for PLS in the spectral region between 295 and 540 nm and for MLR-SPA. Tablets of commercial samples were analysed and the results obtained are in close agreement with both, spectrophotometric and HPLC pharmacopeia methods. The sample throughput was 18 h-1. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-05 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/95144 Grunhut, Marcos; Centurión, María Eugenia; Fragoso, Wallace D.; Almeida, Luciano F.; de Araújo, Mário C.U.; et al.; Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm; Elsevier Science; Talanta; 75; 4; 5-2008; 950-958 0039-9140 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/95144 |
identifier_str_mv |
Grunhut, Marcos; Centurión, María Eugenia; Fragoso, Wallace D.; Almeida, Luciano F.; de Araújo, Mário C.U.; et al.; Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm; Elsevier Science; Talanta; 75; 4; 5-2008; 950-958 0039-9140 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0039914007008879 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.talanta.2007.12.029 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier Science |
publisher.none.fl_str_mv |
Elsevier Science |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1846083517656596480 |
score |
13.22299 |