LED fluorescence microscopy in the diagnosis of tuberculosis: Fading and restaining of smears for external quality assessment
- Autores
- Allassia, Sonia; Aranibar, Mónica; Boutonnet, Mónica; Caserío, Viviana; Etchart, Ana Alicia; Fajardo, Sandra; García, Mónica; Gomez, Noemí; Gunia, Alba Marisa; Gustincic, María Virginia; Izquierdo, Viviana; Jara, Arnaldo Andrés; Kozicky, Graciela; Matteo, Mario; Pellegrini, Carlos; Pellegrino, Silvia; Pérez Catalán, Sebastián; Poggi, Susana; Sacramone, Carina; Santiso, Gabriela María; Souto, Alejandro; Togneri, Ana María; Wolff, Lidia; Vilche, Sandra; Eletti, Daniel; Imaz, María Susana
- Año de publicación
- 2016
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Fil: Allassia, Sonia. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina.
Fil: Aranibar, Mónica. Hospital San Roque. Laboratorio de Tuberculosis, San Salvador de Jujuy, Jujuy; Argentina.
Fil: Boutonnet, Mónica. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina.
Fil: Caserío, Viviana. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina.
Fil: Etchart, Ana Alicia. Hospital San Roque. Laboratorio de Tuberculosis, San Salvador de Jujuy, Jujuy; Argentina.
Fil: Fajardo, Sandra. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina.
Fil: García, Mónica. Hospital de Infecciosas Francisco Javier Muñiz. Laboratorio de Tuberculosis, Ciudad Autónoma de Buenos Aires; Argentina.
Fil: Gomez, Noemí. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina.
Fil: Gunia, Alba Marisa. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina.
Fil: Gustincic, María Virginia. Hospital Interzonal General de Agudos Evita. Laboratorio de Bacteriología, Lanús, Buenos Aires; Argentina.
Fil: Izquierdo, Viviana. Hospital San Roque. Laboratorio de Tuberculosis, San Salvador de Jujuy, Jujuy; Argentina.
Fil: Jara, Arnaldo Andrés. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina.
Fil: Kozicky, Graciela. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina.
Fil: Matteo, Mario. Hospital de Infecciosas Francisco Javier Muñiz. Laboratorio de Tuberculosis, Ciudad Autónoma de Buenos Aires; Argentina.
Fil: Pellegrini, Carlos. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina.
Fil: Pellegrino, Silvia. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina.
Fil: Pérez Catalán, Sebastián. Hospital Interzonal General de Agudos Evita. Laboratorio de Bacteriología, Lanús, Buenos Aires; Argentina.
Fil: Poggi, Susana. Hospital de Infecciosas Francisco Javier Muñiz. Laboratorio de Tuberculosis, Ciudad Autónoma de Buenos Aires; Argentina.
Fil: Sacramone, Carina. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina.
Fil: Santiso, Gabriela María. Hospital Interzonal General de Agudos Evita. Laboratorio de Bacteriología, Lanús, Buenos Aires; Argentina.
Fil: Souto, Alejandro. Hospital de Infecciosas Francisco Javier Muñiz. Laboratorio de Tuberculosis, Ciudad Autónoma de Buenos Aires; Argentina.
Fil: Togneri, Ana María. Hospital Interzonal General de Agudos Evita. Laboratorio de Bacteriología, Lanús, Buenos Aires; Argentina.
Fil: Wolff, Lidia. Hospital Rawson. Laboratorio de Bacteriología, Córdoba; Argentina.
Fil: Vilche, Sandra. ANLIS Dr.C.G.Malbrán. Instituto Nacional de Enfermedades Respiratorias. Departamento de Diagnóstico y Referencia; Argentina.
Fil: Eletti, Daniel. ANLIS Dr.C.G.Malbrán. Instituto Nacional de Enfermedades Respiratorias. Departamento de Diagnóstico y Referencia; Argentina.a.
Fil: Imaz, María Susana. ANLIS Dr.C.G.Malbrán. Instituto Nacional de Enfermedades Respiratorias. Departamento de Diagnóstico y Referencia; Argentina.
Blinded rechecking is a method proposed for external quality assurance (EQA) of auramine-stained acid-fast bacilli (AFB) smears using fluorescence microscopy (FM), however, this procedure is not well developed and slides fading over time could compromise its implementation. Since bleaching of fluorescent molecules involves temperature-dependent chemical reactions, it is likely that low temperatures could slow down this process. We stored auramine-stained slides under different environmental conditions, including -20°C, and examined them over time. The slides stored in all the environments faded. At -20°C, fading was not reduced in relation to room temperature. Restaining and re-examining smears after five months showed that the slides containing saliva and storage at -20°C were associated with failure in AFB reappearance. In conclusion, the practice of freezing slides until they are viewed should be discouraged as it has a negative effect on blinded rechecking by reducing reading concordance after restaining. Specimen quality should be considered when interpreting FM-EQA results. - Fuente
- Revista Argentina de Microbiología 2016;48(2):122-127
- Materia
-
Microscopía Fluorescente
Evaluación externa de calidad
Tuberculosis
Enterobacteriaceae - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- Repositorio
- Institución
- Administración Nacional de Laboratorios e Institutos de Salud "Dr. Carlos G. Malbrán"
- OAI Identificador
- oai:sgc.anlis.gob.ar:Publications/123456789/1403
Ver los metadatos del registro completo
id |
SGCANLIS_341d6b7a78259f93c2a0baddd2ac60c4 |
---|---|
oai_identifier_str |
oai:sgc.anlis.gob.ar:Publications/123456789/1403 |
network_acronym_str |
SGCANLIS |
repository_id_str |
a |
network_name_str |
Sistema de Gestión del Conocimiento ANLIS MALBRÁN |
spelling |
LED fluorescence microscopy in the diagnosis of tuberculosis: Fading and restaining of smears for external quality assessmentAllassia, SoniaAranibar, MónicaBoutonnet, MónicaCaserío, VivianaEtchart, Ana AliciaFajardo, SandraGarcía, MónicaGomez, NoemíGunia, Alba MarisaGustincic, María VirginiaIzquierdo, VivianaJara, Arnaldo AndrésKozicky, GracielaMatteo, MarioPellegrini, CarlosPellegrino, SilviaPérez Catalán, SebastiánPoggi, SusanaSacramone, CarinaSantiso, Gabriela MaríaSouto, AlejandroTogneri, Ana MaríaWolff, LidiaVilche, SandraEletti, DanielImaz, María SusanaMicroscopía FluorescenteEvaluación externa de calidadTuberculosisEnterobacteriaceaeFil: Allassia, Sonia. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina.Fil: Aranibar, Mónica. Hospital San Roque. Laboratorio de Tuberculosis, San Salvador de Jujuy, Jujuy; Argentina.Fil: Boutonnet, Mónica. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina.Fil: Caserío, Viviana. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina.Fil: Etchart, Ana Alicia. Hospital San Roque. Laboratorio de Tuberculosis, San Salvador de Jujuy, Jujuy; Argentina.Fil: Fajardo, Sandra. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina.Fil: García, Mónica. Hospital de Infecciosas Francisco Javier Muñiz. Laboratorio de Tuberculosis, Ciudad Autónoma de Buenos Aires; Argentina.Fil: Gomez, Noemí. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina.Fil: Gunia, Alba Marisa. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina.Fil: Gustincic, María Virginia. Hospital Interzonal General de Agudos Evita. Laboratorio de Bacteriología, Lanús, Buenos Aires; Argentina.Fil: Izquierdo, Viviana. Hospital San Roque. Laboratorio de Tuberculosis, San Salvador de Jujuy, Jujuy; Argentina.Fil: Jara, Arnaldo Andrés. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina.Fil: Kozicky, Graciela. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina.Fil: Matteo, Mario. Hospital de Infecciosas Francisco Javier Muñiz. Laboratorio de Tuberculosis, Ciudad Autónoma de Buenos Aires; Argentina.Fil: Pellegrini, Carlos. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina.Fil: Pellegrino, Silvia. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina.Fil: Pérez Catalán, Sebastián. Hospital Interzonal General de Agudos Evita. Laboratorio de Bacteriología, Lanús, Buenos Aires; Argentina.Fil: Poggi, Susana. Hospital de Infecciosas Francisco Javier Muñiz. Laboratorio de Tuberculosis, Ciudad Autónoma de Buenos Aires; Argentina.Fil: Sacramone, Carina. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina.Fil: Santiso, Gabriela María. Hospital Interzonal General de Agudos Evita. Laboratorio de Bacteriología, Lanús, Buenos Aires; Argentina.Fil: Souto, Alejandro. Hospital de Infecciosas Francisco Javier Muñiz. Laboratorio de Tuberculosis, Ciudad Autónoma de Buenos Aires; Argentina.Fil: Togneri, Ana María. Hospital Interzonal General de Agudos Evita. Laboratorio de Bacteriología, Lanús, Buenos Aires; Argentina.Fil: Wolff, Lidia. Hospital Rawson. Laboratorio de Bacteriología, Córdoba; Argentina.Fil: Vilche, Sandra. ANLIS Dr.C.G.Malbrán. Instituto Nacional de Enfermedades Respiratorias. Departamento de Diagnóstico y Referencia; Argentina.Fil: Eletti, Daniel. ANLIS Dr.C.G.Malbrán. Instituto Nacional de Enfermedades Respiratorias. Departamento de Diagnóstico y Referencia; Argentina.a.Fil: Imaz, María Susana. ANLIS Dr.C.G.Malbrán. Instituto Nacional de Enfermedades Respiratorias. Departamento de Diagnóstico y Referencia; Argentina.Blinded rechecking is a method proposed for external quality assurance (EQA) of auramine-stained acid-fast bacilli (AFB) smears using fluorescence microscopy (FM), however, this procedure is not well developed and slides fading over time could compromise its implementation. Since bleaching of fluorescent molecules involves temperature-dependent chemical reactions, it is likely that low temperatures could slow down this process. We stored auramine-stained slides under different environmental conditions, including -20°C, and examined them over time. The slides stored in all the environments faded. At -20°C, fading was not reduced in relation to room temperature. Restaining and re-examining smears after five months showed that the slides containing saliva and storage at -20°C were associated with failure in AFB reappearance. In conclusion, the practice of freezing slides until they are viewed should be discouraged as it has a negative effect on blinded rechecking by reducing reading concordance after restaining. Specimen quality should be considered when interpreting FM-EQA results.2016info:ar-repo/semantics/articuloinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdf0325-7541http://sgc.anlis.gob.ar/handle/123456789/140310.1016/j.ram.2016.03.006Revista Argentina de Microbiología 2016;48(2):122-127reponame:Sistema de Gestión del Conocimiento ANLIS MALBRÁNinstname:Administración Nacional de Laboratorios e Institutos de Salud "Dr. Carlos G. Malbrán"instacron:ANLISRevista Argentina de microbiologiaenginfo:eu-repo/semantics/openAccess2025-09-29T14:30:18Zoai:sgc.anlis.gob.ar:Publications/123456789/1403Institucionalhttp://sgc.anlis.gob.ar/Organismo científico-tecnológicoNo correspondehttp://sgc.anlis.gob.ar/oai/biblioteca@anlis.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:a2025-09-29 14:30:18.899Sistema de Gestión del Conocimiento ANLIS MALBRÁN - Administración Nacional de Laboratorios e Institutos de Salud "Dr. Carlos G. Malbrán"false |
dc.title.none.fl_str_mv |
LED fluorescence microscopy in the diagnosis of tuberculosis: Fading and restaining of smears for external quality assessment |
title |
LED fluorescence microscopy in the diagnosis of tuberculosis: Fading and restaining of smears for external quality assessment |
spellingShingle |
LED fluorescence microscopy in the diagnosis of tuberculosis: Fading and restaining of smears for external quality assessment Allassia, Sonia Microscopía Fluorescente Evaluación externa de calidad Tuberculosis Enterobacteriaceae |
title_short |
LED fluorescence microscopy in the diagnosis of tuberculosis: Fading and restaining of smears for external quality assessment |
title_full |
LED fluorescence microscopy in the diagnosis of tuberculosis: Fading and restaining of smears for external quality assessment |
title_fullStr |
LED fluorescence microscopy in the diagnosis of tuberculosis: Fading and restaining of smears for external quality assessment |
title_full_unstemmed |
LED fluorescence microscopy in the diagnosis of tuberculosis: Fading and restaining of smears for external quality assessment |
title_sort |
LED fluorescence microscopy in the diagnosis of tuberculosis: Fading and restaining of smears for external quality assessment |
dc.creator.none.fl_str_mv |
Allassia, Sonia Aranibar, Mónica Boutonnet, Mónica Caserío, Viviana Etchart, Ana Alicia Fajardo, Sandra García, Mónica Gomez, Noemí Gunia, Alba Marisa Gustincic, María Virginia Izquierdo, Viviana Jara, Arnaldo Andrés Kozicky, Graciela Matteo, Mario Pellegrini, Carlos Pellegrino, Silvia Pérez Catalán, Sebastián Poggi, Susana Sacramone, Carina Santiso, Gabriela María Souto, Alejandro Togneri, Ana María Wolff, Lidia Vilche, Sandra Eletti, Daniel Imaz, María Susana |
author |
Allassia, Sonia |
author_facet |
Allassia, Sonia Aranibar, Mónica Boutonnet, Mónica Caserío, Viviana Etchart, Ana Alicia Fajardo, Sandra García, Mónica Gomez, Noemí Gunia, Alba Marisa Gustincic, María Virginia Izquierdo, Viviana Jara, Arnaldo Andrés Kozicky, Graciela Matteo, Mario Pellegrini, Carlos Pellegrino, Silvia Pérez Catalán, Sebastián Poggi, Susana Sacramone, Carina Santiso, Gabriela María Souto, Alejandro Togneri, Ana María Wolff, Lidia Vilche, Sandra Eletti, Daniel Imaz, María Susana |
author_role |
author |
author2 |
Aranibar, Mónica Boutonnet, Mónica Caserío, Viviana Etchart, Ana Alicia Fajardo, Sandra García, Mónica Gomez, Noemí Gunia, Alba Marisa Gustincic, María Virginia Izquierdo, Viviana Jara, Arnaldo Andrés Kozicky, Graciela Matteo, Mario Pellegrini, Carlos Pellegrino, Silvia Pérez Catalán, Sebastián Poggi, Susana Sacramone, Carina Santiso, Gabriela María Souto, Alejandro Togneri, Ana María Wolff, Lidia Vilche, Sandra Eletti, Daniel Imaz, María Susana |
author2_role |
author author author author author author author author author author author author author author author author author author author author author author author author author |
dc.subject.none.fl_str_mv |
Microscopía Fluorescente Evaluación externa de calidad Tuberculosis Enterobacteriaceae |
topic |
Microscopía Fluorescente Evaluación externa de calidad Tuberculosis Enterobacteriaceae |
dc.description.none.fl_txt_mv |
Fil: Allassia, Sonia. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina. Fil: Aranibar, Mónica. Hospital San Roque. Laboratorio de Tuberculosis, San Salvador de Jujuy, Jujuy; Argentina. Fil: Boutonnet, Mónica. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina. Fil: Caserío, Viviana. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina. Fil: Etchart, Ana Alicia. Hospital San Roque. Laboratorio de Tuberculosis, San Salvador de Jujuy, Jujuy; Argentina. Fil: Fajardo, Sandra. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina. Fil: García, Mónica. Hospital de Infecciosas Francisco Javier Muñiz. Laboratorio de Tuberculosis, Ciudad Autónoma de Buenos Aires; Argentina. Fil: Gomez, Noemí. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina. Fil: Gunia, Alba Marisa. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina. Fil: Gustincic, María Virginia. Hospital Interzonal General de Agudos Evita. Laboratorio de Bacteriología, Lanús, Buenos Aires; Argentina. Fil: Izquierdo, Viviana. Hospital San Roque. Laboratorio de Tuberculosis, San Salvador de Jujuy, Jujuy; Argentina. Fil: Jara, Arnaldo Andrés. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina. Fil: Kozicky, Graciela. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina. Fil: Matteo, Mario. Hospital de Infecciosas Francisco Javier Muñiz. Laboratorio de Tuberculosis, Ciudad Autónoma de Buenos Aires; Argentina. Fil: Pellegrini, Carlos. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina. Fil: Pellegrino, Silvia. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina. Fil: Pérez Catalán, Sebastián. Hospital Interzonal General de Agudos Evita. Laboratorio de Bacteriología, Lanús, Buenos Aires; Argentina. Fil: Poggi, Susana. Hospital de Infecciosas Francisco Javier Muñiz. Laboratorio de Tuberculosis, Ciudad Autónoma de Buenos Aires; Argentina. Fil: Sacramone, Carina. Laboratorio Central de Salud Pública. Laboratorio de Tuberculosis, Resistencia, Chaco; Argentina. Fil: Santiso, Gabriela María. Hospital Interzonal General de Agudos Evita. Laboratorio de Bacteriología, Lanús, Buenos Aires; Argentina. Fil: Souto, Alejandro. Hospital de Infecciosas Francisco Javier Muñiz. Laboratorio de Tuberculosis, Ciudad Autónoma de Buenos Aires; Argentina. Fil: Togneri, Ana María. Hospital Interzonal General de Agudos Evita. Laboratorio de Bacteriología, Lanús, Buenos Aires; Argentina. Fil: Wolff, Lidia. Hospital Rawson. Laboratorio de Bacteriología, Córdoba; Argentina. Fil: Vilche, Sandra. ANLIS Dr.C.G.Malbrán. Instituto Nacional de Enfermedades Respiratorias. Departamento de Diagnóstico y Referencia; Argentina. Fil: Eletti, Daniel. ANLIS Dr.C.G.Malbrán. Instituto Nacional de Enfermedades Respiratorias. Departamento de Diagnóstico y Referencia; Argentina.a. Fil: Imaz, María Susana. ANLIS Dr.C.G.Malbrán. Instituto Nacional de Enfermedades Respiratorias. Departamento de Diagnóstico y Referencia; Argentina. Blinded rechecking is a method proposed for external quality assurance (EQA) of auramine-stained acid-fast bacilli (AFB) smears using fluorescence microscopy (FM), however, this procedure is not well developed and slides fading over time could compromise its implementation. Since bleaching of fluorescent molecules involves temperature-dependent chemical reactions, it is likely that low temperatures could slow down this process. We stored auramine-stained slides under different environmental conditions, including -20°C, and examined them over time. The slides stored in all the environments faded. At -20°C, fading was not reduced in relation to room temperature. Restaining and re-examining smears after five months showed that the slides containing saliva and storage at -20°C were associated with failure in AFB reappearance. In conclusion, the practice of freezing slides until they are viewed should be discouraged as it has a negative effect on blinded rechecking by reducing reading concordance after restaining. Specimen quality should be considered when interpreting FM-EQA results. |
description |
Fil: Allassia, Sonia. Dirección de Bioquímica de la Municipalidad de Rosario, Rosario, Santa Fe; Argentina. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016 |
dc.type.none.fl_str_mv |
info:ar-repo/semantics/articulo info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
0325-7541 http://sgc.anlis.gob.ar/handle/123456789/1403 10.1016/j.ram.2016.03.006 |
identifier_str_mv |
0325-7541 10.1016/j.ram.2016.03.006 |
url |
http://sgc.anlis.gob.ar/handle/123456789/1403 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Revista Argentina de microbiologia |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
Revista Argentina de Microbiología 2016;48(2):122-127 reponame:Sistema de Gestión del Conocimiento ANLIS MALBRÁN instname:Administración Nacional de Laboratorios e Institutos de Salud "Dr. Carlos G. Malbrán" instacron:ANLIS |
reponame_str |
Sistema de Gestión del Conocimiento ANLIS MALBRÁN |
collection |
Sistema de Gestión del Conocimiento ANLIS MALBRÁN |
instname_str |
Administración Nacional de Laboratorios e Institutos de Salud "Dr. Carlos G. Malbrán" |
instacron_str |
ANLIS |
institution |
ANLIS |
repository.name.fl_str_mv |
Sistema de Gestión del Conocimiento ANLIS MALBRÁN - Administración Nacional de Laboratorios e Institutos de Salud "Dr. Carlos G. Malbrán" |
repository.mail.fl_str_mv |
biblioteca@anlis.gov.ar |
_version_ |
1844621855842893824 |
score |
12.559606 |