STATCOM modeling for mitigation of voltage fluctuations caused by electric arc furnaces
- Autores
- Agüero, Jorge Luis; Issouribehere, Fernando; Battaiotto, Pedro Eduardo
- Año de publicación
- 2006
- Idioma
- inglés
- Tipo de recurso
- documento de conferencia
- Estado
- versión publicada
- Descripción
- Voltage fluctuations caused by rapid industrial load changes have been a major concern for both power companies and customers in the area of power quality. The fast response of the Static Compensator (STATCOM) makes it an efficient solution for improving power quality in distribution systems. This paper describes a model for a PWM-based STATCOM used in a distribution system for mitigation of voltage fluctuations produced by an Electric Arc Furnace (EAF). The analyzed system is modeled using MATLAB/Simulink Power System Blockset (PSB), including a complete STATCOM model with its power circuits and its control system. The complete model is validated by field test. Static and dynamic performance of STATCOM is evaluated and voltage fluctuation mitigation studies are performed and discussed. The voltage fluctuation mitigation is obtained by measurements and according to international standards.
Instituto de Investigaciones Tecnológicas para Redes y Equipos Eléctricos - Materia
-
Ingeniería
Electrotecnia
industria eléctrica
Energía Eléctrica - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- http://creativecommons.org/licenses/by/3.0/
- Repositorio
- Institución
- Universidad Nacional de La Plata
- OAI Identificador
- oai:sedici.unlp.edu.ar:10915/36768
Ver los metadatos del registro completo
id |
SEDICI_de74b14ae43e163ec575081f792802c2 |
---|---|
oai_identifier_str |
oai:sedici.unlp.edu.ar:10915/36768 |
network_acronym_str |
SEDICI |
repository_id_str |
1329 |
network_name_str |
SEDICI (UNLP) |
spelling |
STATCOM modeling for mitigation of voltage fluctuations caused by electric arc furnacesAgüero, Jorge LuisIssouribehere, FernandoBattaiotto, Pedro EduardoIngenieríaElectrotecniaindustria eléctricaEnergía EléctricaVoltage fluctuations caused by rapid industrial load changes have been a major concern for both power companies and customers in the area of power quality. The fast response of the Static Compensator (STATCOM) makes it an efficient solution for improving power quality in distribution systems. This paper describes a model for a PWM-based STATCOM used in a distribution system for mitigation of voltage fluctuations produced by an Electric Arc Furnace (EAF). The analyzed system is modeled using MATLAB/Simulink Power System Blockset (PSB), including a complete STATCOM model with its power circuits and its control system. The complete model is validated by field test. Static and dynamic performance of STATCOM is evaluated and voltage fluctuation mitigation studies are performed and discussed. The voltage fluctuation mitigation is obtained by measurements and according to international standards.Instituto de Investigaciones Tecnológicas para Redes y Equipos Eléctricos2006-06info:eu-repo/semantics/conferenceObjectinfo:eu-repo/semantics/publishedVersionResumenhttp://purl.org/coar/resource_type/c_5794info:ar-repo/semantics/documentoDeConferenciaapplication/pdfhttp://sedici.unlp.edu.ar/handle/10915/36768enginfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by/3.0/Creative Commons Attribution 3.0 Unported (CC BY 3.0)reponame:SEDICI (UNLP)instname:Universidad Nacional de La Platainstacron:UNLP2025-09-03T10:32:25Zoai:sedici.unlp.edu.ar:10915/36768Institucionalhttp://sedici.unlp.edu.ar/Universidad públicaNo correspondehttp://sedici.unlp.edu.ar/oai/snrdalira@sedici.unlp.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:13292025-09-03 10:32:25.759SEDICI (UNLP) - Universidad Nacional de La Platafalse |
dc.title.none.fl_str_mv |
STATCOM modeling for mitigation of voltage fluctuations caused by electric arc furnaces |
title |
STATCOM modeling for mitigation of voltage fluctuations caused by electric arc furnaces |
spellingShingle |
STATCOM modeling for mitigation of voltage fluctuations caused by electric arc furnaces Agüero, Jorge Luis Ingeniería Electrotecnia industria eléctrica Energía Eléctrica |
title_short |
STATCOM modeling for mitigation of voltage fluctuations caused by electric arc furnaces |
title_full |
STATCOM modeling for mitigation of voltage fluctuations caused by electric arc furnaces |
title_fullStr |
STATCOM modeling for mitigation of voltage fluctuations caused by electric arc furnaces |
title_full_unstemmed |
STATCOM modeling for mitigation of voltage fluctuations caused by electric arc furnaces |
title_sort |
STATCOM modeling for mitigation of voltage fluctuations caused by electric arc furnaces |
dc.creator.none.fl_str_mv |
Agüero, Jorge Luis Issouribehere, Fernando Battaiotto, Pedro Eduardo |
author |
Agüero, Jorge Luis |
author_facet |
Agüero, Jorge Luis Issouribehere, Fernando Battaiotto, Pedro Eduardo |
author_role |
author |
author2 |
Issouribehere, Fernando Battaiotto, Pedro Eduardo |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Ingeniería Electrotecnia industria eléctrica Energía Eléctrica |
topic |
Ingeniería Electrotecnia industria eléctrica Energía Eléctrica |
dc.description.none.fl_txt_mv |
Voltage fluctuations caused by rapid industrial load changes have been a major concern for both power companies and customers in the area of power quality. The fast response of the Static Compensator (STATCOM) makes it an efficient solution for improving power quality in distribution systems. This paper describes a model for a PWM-based STATCOM used in a distribution system for mitigation of voltage fluctuations produced by an Electric Arc Furnace (EAF). The analyzed system is modeled using MATLAB/Simulink Power System Blockset (PSB), including a complete STATCOM model with its power circuits and its control system. The complete model is validated by field test. Static and dynamic performance of STATCOM is evaluated and voltage fluctuation mitigation studies are performed and discussed. The voltage fluctuation mitigation is obtained by measurements and according to international standards. Instituto de Investigaciones Tecnológicas para Redes y Equipos Eléctricos |
description |
Voltage fluctuations caused by rapid industrial load changes have been a major concern for both power companies and customers in the area of power quality. The fast response of the Static Compensator (STATCOM) makes it an efficient solution for improving power quality in distribution systems. This paper describes a model for a PWM-based STATCOM used in a distribution system for mitigation of voltage fluctuations produced by an Electric Arc Furnace (EAF). The analyzed system is modeled using MATLAB/Simulink Power System Blockset (PSB), including a complete STATCOM model with its power circuits and its control system. The complete model is validated by field test. Static and dynamic performance of STATCOM is evaluated and voltage fluctuation mitigation studies are performed and discussed. The voltage fluctuation mitigation is obtained by measurements and according to international standards. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-06 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/conferenceObject info:eu-repo/semantics/publishedVersion Resumen http://purl.org/coar/resource_type/c_5794 info:ar-repo/semantics/documentoDeConferencia |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://sedici.unlp.edu.ar/handle/10915/36768 |
url |
http://sedici.unlp.edu.ar/handle/10915/36768 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/3.0/ Creative Commons Attribution 3.0 Unported (CC BY 3.0) |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by/3.0/ Creative Commons Attribution 3.0 Unported (CC BY 3.0) |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:SEDICI (UNLP) instname:Universidad Nacional de La Plata instacron:UNLP |
reponame_str |
SEDICI (UNLP) |
collection |
SEDICI (UNLP) |
instname_str |
Universidad Nacional de La Plata |
instacron_str |
UNLP |
institution |
UNLP |
repository.name.fl_str_mv |
SEDICI (UNLP) - Universidad Nacional de La Plata |
repository.mail.fl_str_mv |
alira@sedici.unlp.edu.ar |
_version_ |
1842260171655479296 |
score |
13.13397 |