Power quality measurements and operating characteristics of electric arc furnaces
- Autores
- Issouribehere, Fernando; Issouribehere, Pedro; Barbera, Gustavo Ariel
- Año de publicación
- 2005
- Idioma
- inglés
- Tipo de recurso
- documento de conferencia
- Estado
- versión publicada
- Descripción
- Power quality is of increasing concern to utilities and their customer alike. Many loads connected to electric power systems can cause power quality problems at all voltage levels and for very different power ratings due to their unbalanced and non-linear behaviour characteristics. This paper describes the aspects of power quality at the point of common coupling (PCC) where an arc furnace for steel melting with alternating current is connected. By measurements of flicker, harmonics content in voltage and current, active and reactive power and power factor, the preservation of the reference levels for the supply voltage and emission limits for the furnace as a customer are evaluated. The evaluation of the power quality of contemporary International and Argentinian standards is given. The different phases in the operation of the arc furnace are described in detail and illustrated with measurements, and a complete single phase equivalent circuit for the arc furnace is obtained from field tests.
Instituto de Investigaciones Tecnológicas para Redes y Equipos Eléctricos (IITREE) - Materia
-
Ingeniería
Energía Eléctrica
arc furnaces
power quality
flicker
harmonics - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- http://creativecommons.org/licenses/by/3.0/
- Repositorio
- Institución
- Universidad Nacional de La Plata
- OAI Identificador
- oai:sedici.unlp.edu.ar:10915/36730
Ver los metadatos del registro completo
id |
SEDICI_cab55db1b4fcd161c87086f7123f9f3e |
---|---|
oai_identifier_str |
oai:sedici.unlp.edu.ar:10915/36730 |
network_acronym_str |
SEDICI |
repository_id_str |
1329 |
network_name_str |
SEDICI (UNLP) |
spelling |
Power quality measurements and operating characteristics of electric arc furnacesIssouribehere, FernandoIssouribehere, PedroBarbera, Gustavo ArielIngenieríaEnergía Eléctricaarc furnacespower qualityflickerharmonicsPower quality is of increasing concern to utilities and their customer alike. Many loads connected to electric power systems can cause power quality problems at all voltage levels and for very different power ratings due to their unbalanced and non-linear behaviour characteristics. This paper describes the aspects of power quality at the point of common coupling (PCC) where an arc furnace for steel melting with alternating current is connected. By measurements of flicker, harmonics content in voltage and current, active and reactive power and power factor, the preservation of the reference levels for the supply voltage and emission limits for the furnace as a customer are evaluated. The evaluation of the power quality of contemporary International and Argentinian standards is given. The different phases in the operation of the arc furnace are described in detail and illustrated with measurements, and a complete single phase equivalent circuit for the arc furnace is obtained from field tests.Instituto de Investigaciones Tecnológicas para Redes y Equipos Eléctricos (IITREE)2005-05info:eu-repo/semantics/conferenceObjectinfo:eu-repo/semantics/publishedVersionObjeto de conferenciahttp://purl.org/coar/resource_type/c_5794info:ar-repo/semantics/documentoDeConferenciaapplication/pdfhttp://sedici.unlp.edu.ar/handle/10915/36730enginfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by/3.0/Creative Commons Attribution 3.0 Unported (CC BY 3.0)reponame:SEDICI (UNLP)instname:Universidad Nacional de La Platainstacron:UNLP2025-09-03T10:32:24Zoai:sedici.unlp.edu.ar:10915/36730Institucionalhttp://sedici.unlp.edu.ar/Universidad públicaNo correspondehttp://sedici.unlp.edu.ar/oai/snrdalira@sedici.unlp.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:13292025-09-03 10:32:25.134SEDICI (UNLP) - Universidad Nacional de La Platafalse |
dc.title.none.fl_str_mv |
Power quality measurements and operating characteristics of electric arc furnaces |
title |
Power quality measurements and operating characteristics of electric arc furnaces |
spellingShingle |
Power quality measurements and operating characteristics of electric arc furnaces Issouribehere, Fernando Ingeniería Energía Eléctrica arc furnaces power quality flicker harmonics |
title_short |
Power quality measurements and operating characteristics of electric arc furnaces |
title_full |
Power quality measurements and operating characteristics of electric arc furnaces |
title_fullStr |
Power quality measurements and operating characteristics of electric arc furnaces |
title_full_unstemmed |
Power quality measurements and operating characteristics of electric arc furnaces |
title_sort |
Power quality measurements and operating characteristics of electric arc furnaces |
dc.creator.none.fl_str_mv |
Issouribehere, Fernando Issouribehere, Pedro Barbera, Gustavo Ariel |
author |
Issouribehere, Fernando |
author_facet |
Issouribehere, Fernando Issouribehere, Pedro Barbera, Gustavo Ariel |
author_role |
author |
author2 |
Issouribehere, Pedro Barbera, Gustavo Ariel |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Ingeniería Energía Eléctrica arc furnaces power quality flicker harmonics |
topic |
Ingeniería Energía Eléctrica arc furnaces power quality flicker harmonics |
dc.description.none.fl_txt_mv |
Power quality is of increasing concern to utilities and their customer alike. Many loads connected to electric power systems can cause power quality problems at all voltage levels and for very different power ratings due to their unbalanced and non-linear behaviour characteristics. This paper describes the aspects of power quality at the point of common coupling (PCC) where an arc furnace for steel melting with alternating current is connected. By measurements of flicker, harmonics content in voltage and current, active and reactive power and power factor, the preservation of the reference levels for the supply voltage and emission limits for the furnace as a customer are evaluated. The evaluation of the power quality of contemporary International and Argentinian standards is given. The different phases in the operation of the arc furnace are described in detail and illustrated with measurements, and a complete single phase equivalent circuit for the arc furnace is obtained from field tests. Instituto de Investigaciones Tecnológicas para Redes y Equipos Eléctricos (IITREE) |
description |
Power quality is of increasing concern to utilities and their customer alike. Many loads connected to electric power systems can cause power quality problems at all voltage levels and for very different power ratings due to their unbalanced and non-linear behaviour characteristics. This paper describes the aspects of power quality at the point of common coupling (PCC) where an arc furnace for steel melting with alternating current is connected. By measurements of flicker, harmonics content in voltage and current, active and reactive power and power factor, the preservation of the reference levels for the supply voltage and emission limits for the furnace as a customer are evaluated. The evaluation of the power quality of contemporary International and Argentinian standards is given. The different phases in the operation of the arc furnace are described in detail and illustrated with measurements, and a complete single phase equivalent circuit for the arc furnace is obtained from field tests. |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005-05 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/conferenceObject info:eu-repo/semantics/publishedVersion Objeto de conferencia http://purl.org/coar/resource_type/c_5794 info:ar-repo/semantics/documentoDeConferencia |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://sedici.unlp.edu.ar/handle/10915/36730 |
url |
http://sedici.unlp.edu.ar/handle/10915/36730 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/3.0/ Creative Commons Attribution 3.0 Unported (CC BY 3.0) |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by/3.0/ Creative Commons Attribution 3.0 Unported (CC BY 3.0) |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:SEDICI (UNLP) instname:Universidad Nacional de La Plata instacron:UNLP |
reponame_str |
SEDICI (UNLP) |
collection |
SEDICI (UNLP) |
instname_str |
Universidad Nacional de La Plata |
instacron_str |
UNLP |
institution |
UNLP |
repository.name.fl_str_mv |
SEDICI (UNLP) - Universidad Nacional de La Plata |
repository.mail.fl_str_mv |
alira@sedici.unlp.edu.ar |
_version_ |
1842260171618779136 |
score |
13.13397 |