Influence of nitric oxide-mediated vasodilation on the blood pressure measured with the tail-cuff method in the rat
- Autores
- Fritz, Mariana; Rinaldi, Gustavo
- Año de publicación
- 2007
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Systolic blood pressure (SBP) is frequently measured in rats by the tail cuff method, which usually comprises pulse/flow disappearance and reappearance during cuff inflation (Inf) and deflation (Def), separated by an interval between cycles (IBC). Although Def values are habitually used to estimate SBP, in 58 Wistar rats we found (Def–Inf) to be −6 ± 1 mmHg, indicating that Def < Inf in most cases. When the IBC was lengthened to 2 min, (Def–Inf) was increased to −17 ± 2 mmHg, indicating the probable accumulation of a vasodilating metabolite. This increase of (Def–Inf) was prevented by papaverine, indicating its relation to smooth muscle contractility. Adrenergic blockade did not prevent the increase of (Def–Inf), but pretreatment with L-NAME decreased it to −5 ± 2 mmHg (p < 0.05). Simultaneous measurement of SBP by tail-cuff method and carotid cannulation revealed that the Inf value was the most accurate estimation of intravascular SBP. We conclude that: (1) the Inf value should be taken as representative of SBP, since depending on the duration of suprasystolic compression the Def value can underestimate it, and (2) nitric oxide accumulation due to flow deprivation was the main cause of SBP underestimation by Def values.
Facultad de Ciencias Exactas
Centro de Investigaciones Cardiovasculares - Materia
-
Ciencias Médicas
L-NAME
Systolic blood pressure
Nitric oxide
Tail-cuff method - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- http://creativecommons.org/licenses/by-nc-sa/4.0/
- Repositorio
- Institución
- Universidad Nacional de La Plata
- OAI Identificador
- oai:sedici.unlp.edu.ar:10915/132487
Ver los metadatos del registro completo
id |
SEDICI_97d5a909201156b1f48dbf9ed6af3e71 |
---|---|
oai_identifier_str |
oai:sedici.unlp.edu.ar:10915/132487 |
network_acronym_str |
SEDICI |
repository_id_str |
1329 |
network_name_str |
SEDICI (UNLP) |
spelling |
Influence of nitric oxide-mediated vasodilation on the blood pressure measured with the tail-cuff method in the ratFritz, MarianaRinaldi, GustavoCiencias MédicasL-NAMESystolic blood pressureNitric oxideTail-cuff methodSystolic blood pressure (SBP) is frequently measured in rats by the tail cuff method, which usually comprises pulse/flow disappearance and reappearance during cuff inflation (Inf) and deflation (Def), separated by an interval between cycles (IBC). Although Def values are habitually used to estimate SBP, in 58 Wistar rats we found (Def–Inf) to be −6 ± 1 mmHg, indicating that Def < Inf in most cases. When the IBC was lengthened to 2 min, (Def–Inf) was increased to −17 ± 2 mmHg, indicating the probable accumulation of a vasodilating metabolite. This increase of (Def–Inf) was prevented by papaverine, indicating its relation to smooth muscle contractility. Adrenergic blockade did not prevent the increase of (Def–Inf), but pretreatment with L-NAME decreased it to −5 ± 2 mmHg (p < 0.05). Simultaneous measurement of SBP by tail-cuff method and carotid cannulation revealed that the Inf value was the most accurate estimation of intravascular SBP. We conclude that: (1) the Inf value should be taken as representative of SBP, since depending on the duration of suprasystolic compression the Def value can underestimate it, and (2) nitric oxide accumulation due to flow deprivation was the main cause of SBP underestimation by Def values.Facultad de Ciencias ExactasCentro de Investigaciones Cardiovasculares2007info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArticulohttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdf757-765http://sedici.unlp.edu.ar/handle/10915/132487enginfo:eu-repo/semantics/altIdentifier/issn/1021-7770info:eu-repo/semantics/altIdentifier/issn/1423-0127info:eu-repo/semantics/altIdentifier/doi/10.1007/s11373-007-9191-1info:eu-repo/semantics/altIdentifier/pmid/17634759info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-sa/4.0/Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)reponame:SEDICI (UNLP)instname:Universidad Nacional de La Platainstacron:UNLP2025-10-15T11:24:04Zoai:sedici.unlp.edu.ar:10915/132487Institucionalhttp://sedici.unlp.edu.ar/Universidad públicaNo correspondehttp://sedici.unlp.edu.ar/oai/snrdalira@sedici.unlp.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:13292025-10-15 11:24:04.485SEDICI (UNLP) - Universidad Nacional de La Platafalse |
dc.title.none.fl_str_mv |
Influence of nitric oxide-mediated vasodilation on the blood pressure measured with the tail-cuff method in the rat |
title |
Influence of nitric oxide-mediated vasodilation on the blood pressure measured with the tail-cuff method in the rat |
spellingShingle |
Influence of nitric oxide-mediated vasodilation on the blood pressure measured with the tail-cuff method in the rat Fritz, Mariana Ciencias Médicas L-NAME Systolic blood pressure Nitric oxide Tail-cuff method |
title_short |
Influence of nitric oxide-mediated vasodilation on the blood pressure measured with the tail-cuff method in the rat |
title_full |
Influence of nitric oxide-mediated vasodilation on the blood pressure measured with the tail-cuff method in the rat |
title_fullStr |
Influence of nitric oxide-mediated vasodilation on the blood pressure measured with the tail-cuff method in the rat |
title_full_unstemmed |
Influence of nitric oxide-mediated vasodilation on the blood pressure measured with the tail-cuff method in the rat |
title_sort |
Influence of nitric oxide-mediated vasodilation on the blood pressure measured with the tail-cuff method in the rat |
dc.creator.none.fl_str_mv |
Fritz, Mariana Rinaldi, Gustavo |
author |
Fritz, Mariana |
author_facet |
Fritz, Mariana Rinaldi, Gustavo |
author_role |
author |
author2 |
Rinaldi, Gustavo |
author2_role |
author |
dc.subject.none.fl_str_mv |
Ciencias Médicas L-NAME Systolic blood pressure Nitric oxide Tail-cuff method |
topic |
Ciencias Médicas L-NAME Systolic blood pressure Nitric oxide Tail-cuff method |
dc.description.none.fl_txt_mv |
Systolic blood pressure (SBP) is frequently measured in rats by the tail cuff method, which usually comprises pulse/flow disappearance and reappearance during cuff inflation (Inf) and deflation (Def), separated by an interval between cycles (IBC). Although Def values are habitually used to estimate SBP, in 58 Wistar rats we found (Def–Inf) to be −6 ± 1 mmHg, indicating that Def < Inf in most cases. When the IBC was lengthened to 2 min, (Def–Inf) was increased to −17 ± 2 mmHg, indicating the probable accumulation of a vasodilating metabolite. This increase of (Def–Inf) was prevented by papaverine, indicating its relation to smooth muscle contractility. Adrenergic blockade did not prevent the increase of (Def–Inf), but pretreatment with L-NAME decreased it to −5 ± 2 mmHg (p < 0.05). Simultaneous measurement of SBP by tail-cuff method and carotid cannulation revealed that the Inf value was the most accurate estimation of intravascular SBP. We conclude that: (1) the Inf value should be taken as representative of SBP, since depending on the duration of suprasystolic compression the Def value can underestimate it, and (2) nitric oxide accumulation due to flow deprivation was the main cause of SBP underestimation by Def values. Facultad de Ciencias Exactas Centro de Investigaciones Cardiovasculares |
description |
Systolic blood pressure (SBP) is frequently measured in rats by the tail cuff method, which usually comprises pulse/flow disappearance and reappearance during cuff inflation (Inf) and deflation (Def), separated by an interval between cycles (IBC). Although Def values are habitually used to estimate SBP, in 58 Wistar rats we found (Def–Inf) to be −6 ± 1 mmHg, indicating that Def < Inf in most cases. When the IBC was lengthened to 2 min, (Def–Inf) was increased to −17 ± 2 mmHg, indicating the probable accumulation of a vasodilating metabolite. This increase of (Def–Inf) was prevented by papaverine, indicating its relation to smooth muscle contractility. Adrenergic blockade did not prevent the increase of (Def–Inf), but pretreatment with L-NAME decreased it to −5 ± 2 mmHg (p < 0.05). Simultaneous measurement of SBP by tail-cuff method and carotid cannulation revealed that the Inf value was the most accurate estimation of intravascular SBP. We conclude that: (1) the Inf value should be taken as representative of SBP, since depending on the duration of suprasystolic compression the Def value can underestimate it, and (2) nitric oxide accumulation due to flow deprivation was the main cause of SBP underestimation by Def values. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Articulo http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://sedici.unlp.edu.ar/handle/10915/132487 |
url |
http://sedici.unlp.edu.ar/handle/10915/132487 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/issn/1021-7770 info:eu-repo/semantics/altIdentifier/issn/1423-0127 info:eu-repo/semantics/altIdentifier/doi/10.1007/s11373-007-9191-1 info:eu-repo/semantics/altIdentifier/pmid/17634759 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by-nc-sa/4.0/ Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-sa/4.0/ Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) |
dc.format.none.fl_str_mv |
application/pdf 757-765 |
dc.source.none.fl_str_mv |
reponame:SEDICI (UNLP) instname:Universidad Nacional de La Plata instacron:UNLP |
reponame_str |
SEDICI (UNLP) |
collection |
SEDICI (UNLP) |
instname_str |
Universidad Nacional de La Plata |
instacron_str |
UNLP |
institution |
UNLP |
repository.name.fl_str_mv |
SEDICI (UNLP) - Universidad Nacional de La Plata |
repository.mail.fl_str_mv |
alira@sedici.unlp.edu.ar |
_version_ |
1846064294913900544 |
score |
12.891075 |