Key Comparison : SIM.L-K3.2008. Calibration of angle standards. Report – Final
- Autores
- Vieira, L. H. Brum; Stone, J.; Viliesid, M.; Gastaldi, B. R.; Przybylska, J.; Chaudhary, K. P.
- Año de publicación
- 2015
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- In 2000, a key comparison, CCL-K3 (optical polygon and angle blocks) was started, piloted by NMISA. Based on it, in 2007, the SIM metrological region started a SIM.L-K3 key comparison piloted by INMETRO. The results of this regional comparison (RMO key comparison) contribute to the Mutual Recognition Arrangement (MRA) between the national metrology institutes of the Metre Convention. It is linked with the CCL-K3 key comparison via laboratories that participated in both the CIPM and the RMO comparisons. This common participation establishes the link between the comparisons and ensures equivalence of national metrology institutes, according to the MRA between NMIs. The SIM NMIs that took part in the CCL-K3 were NIST, NRC and CENAM. However, NRC withdrew from it. GUM from Poland (EURAMET) and NPLI from India (APMP) were invited to participate in the SIM.L-K3 key comparison. The circulation of artefacts (a 12 faces polygon and 4 angle blocks) started in 2008 and was completed in 2009.
Fil: Vieira, L. H. Brum. Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMetro); Brasil
Fil: Stone, J. National Institute of Standards and Technology (NIST); Estados Unidos
Fil: Viliesid, M. Centro Nacional de Metrología (CENAM); México
Fil: Gastaldi, B. R. Instituto Nacional de Tecnología Industrial (INTI); Argentina
Fil: Przybylska, J. Główny Urząd Miar (GUM); Polonia
Fil: Chaudhary, K. P. National Physical Laboratory (NPL); India - Fuente
- Metrología, 52
- Materia
-
Sistema Interamericano de Metrología
Metrología
Calibración
Patrones
Ángulos
Medidores
Mediciones
Instrumentos de medición - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by/3.0/
- Repositorio
- Institución
- Instituto Nacional de Tecnología Industrial
- OAI Identificador
- nuevadc:Gastaldi2015Angle_pdf
Ver los metadatos del registro completo
id |
RIINTI_a6b0e100164da2129485a2fe6c6b1825 |
---|---|
oai_identifier_str |
nuevadc:Gastaldi2015Angle_pdf |
network_acronym_str |
RIINTI |
repository_id_str |
|
network_name_str |
Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI) |
spelling |
Key Comparison : SIM.L-K3.2008. Calibration of angle standards. Report – FinalVieira, L. H. BrumStone, J.Viliesid, M.Gastaldi, B. R.Przybylska, J.Chaudhary, K. P.Sistema Interamericano de MetrologíaMetrologíaCalibraciónPatronesÁngulosMedidoresMedicionesInstrumentos de mediciónIn 2000, a key comparison, CCL-K3 (optical polygon and angle blocks) was started, piloted by NMISA. Based on it, in 2007, the SIM metrological region started a SIM.L-K3 key comparison piloted by INMETRO. The results of this regional comparison (RMO key comparison) contribute to the Mutual Recognition Arrangement (MRA) between the national metrology institutes of the Metre Convention. It is linked with the CCL-K3 key comparison via laboratories that participated in both the CIPM and the RMO comparisons. This common participation establishes the link between the comparisons and ensures equivalence of national metrology institutes, according to the MRA between NMIs. The SIM NMIs that took part in the CCL-K3 were NIST, NRC and CENAM. However, NRC withdrew from it. GUM from Poland (EURAMET) and NPLI from India (APMP) were invited to participate in the SIM.L-K3 key comparison. The circulation of artefacts (a 12 faces polygon and 4 angle blocks) started in 2008 and was completed in 2009.Fil: Vieira, L. H. Brum. Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMetro); BrasilFil: Stone, J. National Institute of Standards and Technology (NIST); Estados UnidosFil: Viliesid, M. Centro Nacional de Metrología (CENAM); MéxicoFil: Gastaldi, B. R. Instituto Nacional de Tecnología Industrial (INTI); ArgentinaFil: Przybylska, J. Główny Urząd Miar (GUM); PoloniaFil: Chaudhary, K. P. National Physical Laboratory (NPL); IndiaIOP Publishing2015info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfGastaldi2015Angle.pdfhttps://app.inti.gob.ar/greenstone3/sites/localsite/collect/nuevadc/index/assoc/Gastaldi.dir/doc.pdfMetrología, 52reponame:Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI)instname:Instituto Nacional de Tecnología Industrialenginfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/3.0/openAccess2025-09-04T11:43:01Znuevadc:Gastaldi2015Angle_pdfinstacron:INTIInstitucionalhttps://app.inti.gob.ar/greenstone3/biblioOrganismo científico-tecnológicohttps://argentina.gob.ar/intihttps://app.inti.gob.ar/greenstone3/oaiserver?verb=Identifypfalcato@inti.gob.arArgentinaopendoar:2025-09-04 11:43:01.608Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI) - Instituto Nacional de Tecnología Industrialfalse |
dc.title.none.fl_str_mv |
Key Comparison : SIM.L-K3.2008. Calibration of angle standards. Report – Final |
title |
Key Comparison : SIM.L-K3.2008. Calibration of angle standards. Report – Final |
spellingShingle |
Key Comparison : SIM.L-K3.2008. Calibration of angle standards. Report – Final Vieira, L. H. Brum Sistema Interamericano de Metrología Metrología Calibración Patrones Ángulos Medidores Mediciones Instrumentos de medición |
title_short |
Key Comparison : SIM.L-K3.2008. Calibration of angle standards. Report – Final |
title_full |
Key Comparison : SIM.L-K3.2008. Calibration of angle standards. Report – Final |
title_fullStr |
Key Comparison : SIM.L-K3.2008. Calibration of angle standards. Report – Final |
title_full_unstemmed |
Key Comparison : SIM.L-K3.2008. Calibration of angle standards. Report – Final |
title_sort |
Key Comparison : SIM.L-K3.2008. Calibration of angle standards. Report – Final |
dc.creator.none.fl_str_mv |
Vieira, L. H. Brum Stone, J. Viliesid, M. Gastaldi, B. R. Przybylska, J. Chaudhary, K. P. |
author |
Vieira, L. H. Brum |
author_facet |
Vieira, L. H. Brum Stone, J. Viliesid, M. Gastaldi, B. R. Przybylska, J. Chaudhary, K. P. |
author_role |
author |
author2 |
Stone, J. Viliesid, M. Gastaldi, B. R. Przybylska, J. Chaudhary, K. P. |
author2_role |
author author author author author |
dc.subject.none.fl_str_mv |
Sistema Interamericano de Metrología Metrología Calibración Patrones Ángulos Medidores Mediciones Instrumentos de medición |
topic |
Sistema Interamericano de Metrología Metrología Calibración Patrones Ángulos Medidores Mediciones Instrumentos de medición |
dc.description.none.fl_txt_mv |
In 2000, a key comparison, CCL-K3 (optical polygon and angle blocks) was started, piloted by NMISA. Based on it, in 2007, the SIM metrological region started a SIM.L-K3 key comparison piloted by INMETRO. The results of this regional comparison (RMO key comparison) contribute to the Mutual Recognition Arrangement (MRA) between the national metrology institutes of the Metre Convention. It is linked with the CCL-K3 key comparison via laboratories that participated in both the CIPM and the RMO comparisons. This common participation establishes the link between the comparisons and ensures equivalence of national metrology institutes, according to the MRA between NMIs. The SIM NMIs that took part in the CCL-K3 were NIST, NRC and CENAM. However, NRC withdrew from it. GUM from Poland (EURAMET) and NPLI from India (APMP) were invited to participate in the SIM.L-K3 key comparison. The circulation of artefacts (a 12 faces polygon and 4 angle blocks) started in 2008 and was completed in 2009. Fil: Vieira, L. H. Brum. Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMetro); Brasil Fil: Stone, J. National Institute of Standards and Technology (NIST); Estados Unidos Fil: Viliesid, M. Centro Nacional de Metrología (CENAM); México Fil: Gastaldi, B. R. Instituto Nacional de Tecnología Industrial (INTI); Argentina Fil: Przybylska, J. Główny Urząd Miar (GUM); Polonia Fil: Chaudhary, K. P. National Physical Laboratory (NPL); India |
description |
In 2000, a key comparison, CCL-K3 (optical polygon and angle blocks) was started, piloted by NMISA. Based on it, in 2007, the SIM metrological region started a SIM.L-K3 key comparison piloted by INMETRO. The results of this regional comparison (RMO key comparison) contribute to the Mutual Recognition Arrangement (MRA) between the national metrology institutes of the Metre Convention. It is linked with the CCL-K3 key comparison via laboratories that participated in both the CIPM and the RMO comparisons. This common participation establishes the link between the comparisons and ensures equivalence of national metrology institutes, according to the MRA between NMIs. The SIM NMIs that took part in the CCL-K3 were NIST, NRC and CENAM. However, NRC withdrew from it. GUM from Poland (EURAMET) and NPLI from India (APMP) were invited to participate in the SIM.L-K3 key comparison. The circulation of artefacts (a 12 faces polygon and 4 angle blocks) started in 2008 and was completed in 2009. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
Gastaldi2015Angle.pdf https://app.inti.gob.ar/greenstone3/sites/localsite/collect/nuevadc/index/assoc/Gastaldi.dir/doc.pdf |
identifier_str_mv |
Gastaldi2015Angle.pdf |
url |
https://app.inti.gob.ar/greenstone3/sites/localsite/collect/nuevadc/index/assoc/Gastaldi.dir/doc.pdf |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by/3.0/ openAccess |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/3.0/ openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
IOP Publishing |
publisher.none.fl_str_mv |
IOP Publishing |
dc.source.none.fl_str_mv |
Metrología, 52 reponame:Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI) instname:Instituto Nacional de Tecnología Industrial |
reponame_str |
Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI) |
collection |
Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI) |
instname_str |
Instituto Nacional de Tecnología Industrial |
repository.name.fl_str_mv |
Repositorio Institucional del Instituto Nacional de Tecnología Industrial (INTI) - Instituto Nacional de Tecnología Industrial |
repository.mail.fl_str_mv |
pfalcato@inti.gob.ar |
_version_ |
1842346558037688320 |
score |
12.623145 |