On-Line Photoinduced Fluorescence for Carbamazepine Determination after Multivariate Optimization
- Autores
- Henestrosa, Cecilia Mariel; Peralta, Cecilia Mariana; Aragón, Leslie Mary; Fernandez, Liliana Patricia; Acosta, Maria Gimena
- Año de publicación
- 2019
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- This work presents a simple and sensitive flow injection fluorimetric methodfor the determination of carbamazepine (CBZ) in pharmaceutical samples. Itis based on the fluorescence signal measurement of the product generated byphotoinduced (λex = 251 nm; λem = 434 nm) using a flow injection manifoldcontaining an on-line homemade photoreactor. In order to optimize the experimental setup, the variable conditions were studied using a multivariateoptimization method, thus finding the set of optimum parameters accordingto the evaluated responses (sensitivity and sampling frequency) and minimizing the number of experiments performed. Under optimal experimentalconditions, linear relationship with good correlation coefficient (0.9956) wasfound between the fluorescence intensity and CBZ concentration in the rangeof 0.13 - 40 µg∙mL−1. The limit of detection was 0.04 µg∙mL−1. The precision ofthe method was satisfactory; the values of relative standard deviations werebetter than 4.36%. The proposed method was validated and successfully applied to the determination of CBZ in pharmaceuticals with good accuracy;being the recovery values from 89.45% - 112.20%.
Fil: Henestrosa, Cecilia Mariel. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Farmacia; Argentina
Fil: Peralta, Cecilia Mariana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Aragón, Leslie Mary. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Farmacia; Argentina
Fil: Fernandez, Liliana Patricia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Acosta, Maria Gimena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina - Materia
-
ON LINE PHOTOINDUCED FLUORESCECNE
CARBAMAZEPINE
MULTIVARIATE OPTIMIZATION - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/104910
Ver los metadatos del registro completo
id |
CONICETDig_fd6c26f8e742fb4fa884b8d40c22f176 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/104910 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
On-Line Photoinduced Fluorescence for Carbamazepine Determination after Multivariate OptimizationHenestrosa, Cecilia MarielPeralta, Cecilia MarianaAragón, Leslie MaryFernandez, Liliana PatriciaAcosta, Maria GimenaON LINE PHOTOINDUCED FLUORESCECNECARBAMAZEPINEMULTIVARIATE OPTIMIZATIONhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1This work presents a simple and sensitive flow injection fluorimetric methodfor the determination of carbamazepine (CBZ) in pharmaceutical samples. Itis based on the fluorescence signal measurement of the product generated byphotoinduced (λex = 251 nm; λem = 434 nm) using a flow injection manifoldcontaining an on-line homemade photoreactor. In order to optimize the experimental setup, the variable conditions were studied using a multivariateoptimization method, thus finding the set of optimum parameters accordingto the evaluated responses (sensitivity and sampling frequency) and minimizing the number of experiments performed. Under optimal experimentalconditions, linear relationship with good correlation coefficient (0.9956) wasfound between the fluorescence intensity and CBZ concentration in the rangeof 0.13 - 40 µg∙mL−1. The limit of detection was 0.04 µg∙mL−1. The precision ofthe method was satisfactory; the values of relative standard deviations werebetter than 4.36%. The proposed method was validated and successfully applied to the determination of CBZ in pharmaceuticals with good accuracy;being the recovery values from 89.45% - 112.20%.Fil: Henestrosa, Cecilia Mariel. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Farmacia; ArgentinaFil: Peralta, Cecilia Mariana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Aragón, Leslie Mary. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Farmacia; ArgentinaFil: Fernandez, Liliana Patricia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Acosta, Maria Gimena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaScientific Research2019-11info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/104910Henestrosa, Cecilia Mariel; Peralta, Cecilia Mariana; Aragón, Leslie Mary; Fernandez, Liliana Patricia; Acosta, Maria Gimena; On-Line Photoinduced Fluorescence for Carbamazepine Determination after Multivariate Optimization; Scientific Research; American Journal of Analytical Chemistry; 10; 11; 11-2019; 513-5272156-8278CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://www.scirp.org/journal/doi.aspx?DOI=10.4236/ajac.2019.1011037info:eu-repo/semantics/altIdentifier/doi/10.4236/ajac.2019.1011037info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T10:06:27Zoai:ri.conicet.gov.ar:11336/104910instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 10:06:27.574CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
On-Line Photoinduced Fluorescence for Carbamazepine Determination after Multivariate Optimization |
title |
On-Line Photoinduced Fluorescence for Carbamazepine Determination after Multivariate Optimization |
spellingShingle |
On-Line Photoinduced Fluorescence for Carbamazepine Determination after Multivariate Optimization Henestrosa, Cecilia Mariel ON LINE PHOTOINDUCED FLUORESCECNE CARBAMAZEPINE MULTIVARIATE OPTIMIZATION |
title_short |
On-Line Photoinduced Fluorescence for Carbamazepine Determination after Multivariate Optimization |
title_full |
On-Line Photoinduced Fluorescence for Carbamazepine Determination after Multivariate Optimization |
title_fullStr |
On-Line Photoinduced Fluorescence for Carbamazepine Determination after Multivariate Optimization |
title_full_unstemmed |
On-Line Photoinduced Fluorescence for Carbamazepine Determination after Multivariate Optimization |
title_sort |
On-Line Photoinduced Fluorescence for Carbamazepine Determination after Multivariate Optimization |
dc.creator.none.fl_str_mv |
Henestrosa, Cecilia Mariel Peralta, Cecilia Mariana Aragón, Leslie Mary Fernandez, Liliana Patricia Acosta, Maria Gimena |
author |
Henestrosa, Cecilia Mariel |
author_facet |
Henestrosa, Cecilia Mariel Peralta, Cecilia Mariana Aragón, Leslie Mary Fernandez, Liliana Patricia Acosta, Maria Gimena |
author_role |
author |
author2 |
Peralta, Cecilia Mariana Aragón, Leslie Mary Fernandez, Liliana Patricia Acosta, Maria Gimena |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
ON LINE PHOTOINDUCED FLUORESCECNE CARBAMAZEPINE MULTIVARIATE OPTIMIZATION |
topic |
ON LINE PHOTOINDUCED FLUORESCECNE CARBAMAZEPINE MULTIVARIATE OPTIMIZATION |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
This work presents a simple and sensitive flow injection fluorimetric methodfor the determination of carbamazepine (CBZ) in pharmaceutical samples. Itis based on the fluorescence signal measurement of the product generated byphotoinduced (λex = 251 nm; λem = 434 nm) using a flow injection manifoldcontaining an on-line homemade photoreactor. In order to optimize the experimental setup, the variable conditions were studied using a multivariateoptimization method, thus finding the set of optimum parameters accordingto the evaluated responses (sensitivity and sampling frequency) and minimizing the number of experiments performed. Under optimal experimentalconditions, linear relationship with good correlation coefficient (0.9956) wasfound between the fluorescence intensity and CBZ concentration in the rangeof 0.13 - 40 µg∙mL−1. The limit of detection was 0.04 µg∙mL−1. The precision ofthe method was satisfactory; the values of relative standard deviations werebetter than 4.36%. The proposed method was validated and successfully applied to the determination of CBZ in pharmaceuticals with good accuracy;being the recovery values from 89.45% - 112.20%. Fil: Henestrosa, Cecilia Mariel. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Farmacia; Argentina Fil: Peralta, Cecilia Mariana. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina Fil: Aragón, Leslie Mary. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Farmacia; Argentina Fil: Fernandez, Liliana Patricia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina Fil: Acosta, Maria Gimena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina |
description |
This work presents a simple and sensitive flow injection fluorimetric methodfor the determination of carbamazepine (CBZ) in pharmaceutical samples. Itis based on the fluorescence signal measurement of the product generated byphotoinduced (λex = 251 nm; λem = 434 nm) using a flow injection manifoldcontaining an on-line homemade photoreactor. In order to optimize the experimental setup, the variable conditions were studied using a multivariateoptimization method, thus finding the set of optimum parameters accordingto the evaluated responses (sensitivity and sampling frequency) and minimizing the number of experiments performed. Under optimal experimentalconditions, linear relationship with good correlation coefficient (0.9956) wasfound between the fluorescence intensity and CBZ concentration in the rangeof 0.13 - 40 µg∙mL−1. The limit of detection was 0.04 µg∙mL−1. The precision ofthe method was satisfactory; the values of relative standard deviations werebetter than 4.36%. The proposed method was validated and successfully applied to the determination of CBZ in pharmaceuticals with good accuracy;being the recovery values from 89.45% - 112.20%. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-11 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/104910 Henestrosa, Cecilia Mariel; Peralta, Cecilia Mariana; Aragón, Leslie Mary; Fernandez, Liliana Patricia; Acosta, Maria Gimena; On-Line Photoinduced Fluorescence for Carbamazepine Determination after Multivariate Optimization; Scientific Research; American Journal of Analytical Chemistry; 10; 11; 11-2019; 513-527 2156-8278 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/104910 |
identifier_str_mv |
Henestrosa, Cecilia Mariel; Peralta, Cecilia Mariana; Aragón, Leslie Mary; Fernandez, Liliana Patricia; Acosta, Maria Gimena; On-Line Photoinduced Fluorescence for Carbamazepine Determination after Multivariate Optimization; Scientific Research; American Journal of Analytical Chemistry; 10; 11; 11-2019; 513-527 2156-8278 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/http://www.scirp.org/journal/doi.aspx?DOI=10.4236/ajac.2019.1011037 info:eu-repo/semantics/altIdentifier/doi/10.4236/ajac.2019.1011037 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Scientific Research |
publisher.none.fl_str_mv |
Scientific Research |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1842269959537819648 |
score |
13.13397 |