Determination of pesticides and metabolites in wine samples by HPLC-DAD and second-order calibration methods
- Autores
- B. Braga, Jez W.; G. Bottoli, Carla B.; Jardim, Isabel; Goicoechea, Hector Casimiro; Olivieri, Alejandro Cesar; Poppi, Ronei Jesus
- Año de publicación
- 2007
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- The second-order calibration models PARAFAC and the recently introduced BLLS were applied to several chromatographic-diode array detection systems, where overlap of interferences with the compounds of interest was observed, making the determination and resolution of the analytes possible. In this work, the simultaneous determination of five pesticides and two metabolites in wine samples by HPLC-DAD was performed, using the so-called second-order advantage. The results of two chromatographic methods were compared, involving either isocratic or gradient elution. An appropriate preprocessing method was necessary to correct the effects of time shifts, baseline variations and background. BLLS presented results that were of the same quality as PARAFAC in five cases, but in two other situations only PARAFAC enabled analyte quantitation. Relative errors of prediction lower than 10 % for all compounds were obtained, indicating that the methodology employing HLPC-DAD and second-order calibration can handle complex analytical systems.
Fil: B. Braga, Jez W.. Universidade Estadual de Campinas; Brasil
Fil: G. Bottoli, Carla B.. Universidade Estadual de Campinas; Brasil
Fil: Jardim, Isabel. Universidade Estadual de Campinas; Brasil
Fil: Goicoechea, Hector Casimiro. Universidad Nacional del Litoral; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Olivieri, Alejandro Cesar. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Química Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario; Argentina
Fil: Poppi, Ronei Jesus. Universidade Estadual de Campinas; Brasil - Materia
-
BLLS
PARAFAC
Pesticides determination
Wine
HPLC-DAD - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/114383
Ver los metadatos del registro completo
id |
CONICETDig_f83bb84a0b968fdeb5dabc50298f82cd |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/114383 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Determination of pesticides and metabolites in wine samples by HPLC-DAD and second-order calibration methodsB. Braga, Jez W.G. Bottoli, Carla B.Jardim, IsabelGoicoechea, Hector CasimiroOlivieri, Alejandro CesarPoppi, Ronei JesusBLLSPARAFACPesticides determinationWineHPLC-DADhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1The second-order calibration models PARAFAC and the recently introduced BLLS were applied to several chromatographic-diode array detection systems, where overlap of interferences with the compounds of interest was observed, making the determination and resolution of the analytes possible. In this work, the simultaneous determination of five pesticides and two metabolites in wine samples by HPLC-DAD was performed, using the so-called second-order advantage. The results of two chromatographic methods were compared, involving either isocratic or gradient elution. An appropriate preprocessing method was necessary to correct the effects of time shifts, baseline variations and background. BLLS presented results that were of the same quality as PARAFAC in five cases, but in two other situations only PARAFAC enabled analyte quantitation. Relative errors of prediction lower than 10 % for all compounds were obtained, indicating that the methodology employing HLPC-DAD and second-order calibration can handle complex analytical systems.Fil: B. Braga, Jez W.. Universidade Estadual de Campinas; BrasilFil: G. Bottoli, Carla B.. Universidade Estadual de Campinas; BrasilFil: Jardim, Isabel. Universidade Estadual de Campinas; BrasilFil: Goicoechea, Hector Casimiro. Universidad Nacional del Litoral; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Olivieri, Alejandro Cesar. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Química Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario; ArgentinaFil: Poppi, Ronei Jesus. Universidade Estadual de Campinas; BrasilElsevier Science2007-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/114383B. Braga, Jez W.; G. Bottoli, Carla B.; Jardim, Isabel; Goicoechea, Hector Casimiro; Olivieri, Alejandro Cesar; et al.; Determination of pesticides and metabolites in wine samples by HPLC-DAD and second-order calibration methods; Elsevier Science; Journal of Chromatography - A; 1148; 12-2007; 200-2100021-9673CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.chroma.2007.03.018info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-10T13:23:22Zoai:ri.conicet.gov.ar:11336/114383instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-10 13:23:23.152CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Determination of pesticides and metabolites in wine samples by HPLC-DAD and second-order calibration methods |
title |
Determination of pesticides and metabolites in wine samples by HPLC-DAD and second-order calibration methods |
spellingShingle |
Determination of pesticides and metabolites in wine samples by HPLC-DAD and second-order calibration methods B. Braga, Jez W. BLLS PARAFAC Pesticides determination Wine HPLC-DAD |
title_short |
Determination of pesticides and metabolites in wine samples by HPLC-DAD and second-order calibration methods |
title_full |
Determination of pesticides and metabolites in wine samples by HPLC-DAD and second-order calibration methods |
title_fullStr |
Determination of pesticides and metabolites in wine samples by HPLC-DAD and second-order calibration methods |
title_full_unstemmed |
Determination of pesticides and metabolites in wine samples by HPLC-DAD and second-order calibration methods |
title_sort |
Determination of pesticides and metabolites in wine samples by HPLC-DAD and second-order calibration methods |
dc.creator.none.fl_str_mv |
B. Braga, Jez W. G. Bottoli, Carla B. Jardim, Isabel Goicoechea, Hector Casimiro Olivieri, Alejandro Cesar Poppi, Ronei Jesus |
author |
B. Braga, Jez W. |
author_facet |
B. Braga, Jez W. G. Bottoli, Carla B. Jardim, Isabel Goicoechea, Hector Casimiro Olivieri, Alejandro Cesar Poppi, Ronei Jesus |
author_role |
author |
author2 |
G. Bottoli, Carla B. Jardim, Isabel Goicoechea, Hector Casimiro Olivieri, Alejandro Cesar Poppi, Ronei Jesus |
author2_role |
author author author author author |
dc.subject.none.fl_str_mv |
BLLS PARAFAC Pesticides determination Wine HPLC-DAD |
topic |
BLLS PARAFAC Pesticides determination Wine HPLC-DAD |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
The second-order calibration models PARAFAC and the recently introduced BLLS were applied to several chromatographic-diode array detection systems, where overlap of interferences with the compounds of interest was observed, making the determination and resolution of the analytes possible. In this work, the simultaneous determination of five pesticides and two metabolites in wine samples by HPLC-DAD was performed, using the so-called second-order advantage. The results of two chromatographic methods were compared, involving either isocratic or gradient elution. An appropriate preprocessing method was necessary to correct the effects of time shifts, baseline variations and background. BLLS presented results that were of the same quality as PARAFAC in five cases, but in two other situations only PARAFAC enabled analyte quantitation. Relative errors of prediction lower than 10 % for all compounds were obtained, indicating that the methodology employing HLPC-DAD and second-order calibration can handle complex analytical systems. Fil: B. Braga, Jez W.. Universidade Estadual de Campinas; Brasil Fil: G. Bottoli, Carla B.. Universidade Estadual de Campinas; Brasil Fil: Jardim, Isabel. Universidade Estadual de Campinas; Brasil Fil: Goicoechea, Hector Casimiro. Universidad Nacional del Litoral; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Olivieri, Alejandro Cesar. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Rosario. Instituto de Química Rosario. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario; Argentina Fil: Poppi, Ronei Jesus. Universidade Estadual de Campinas; Brasil |
description |
The second-order calibration models PARAFAC and the recently introduced BLLS were applied to several chromatographic-diode array detection systems, where overlap of interferences with the compounds of interest was observed, making the determination and resolution of the analytes possible. In this work, the simultaneous determination of five pesticides and two metabolites in wine samples by HPLC-DAD was performed, using the so-called second-order advantage. The results of two chromatographic methods were compared, involving either isocratic or gradient elution. An appropriate preprocessing method was necessary to correct the effects of time shifts, baseline variations and background. BLLS presented results that were of the same quality as PARAFAC in five cases, but in two other situations only PARAFAC enabled analyte quantitation. Relative errors of prediction lower than 10 % for all compounds were obtained, indicating that the methodology employing HLPC-DAD and second-order calibration can handle complex analytical systems. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-12 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/114383 B. Braga, Jez W.; G. Bottoli, Carla B.; Jardim, Isabel; Goicoechea, Hector Casimiro; Olivieri, Alejandro Cesar; et al.; Determination of pesticides and metabolites in wine samples by HPLC-DAD and second-order calibration methods; Elsevier Science; Journal of Chromatography - A; 1148; 12-2007; 200-210 0021-9673 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/114383 |
identifier_str_mv |
B. Braga, Jez W.; G. Bottoli, Carla B.; Jardim, Isabel; Goicoechea, Hector Casimiro; Olivieri, Alejandro Cesar; et al.; Determination of pesticides and metabolites in wine samples by HPLC-DAD and second-order calibration methods; Elsevier Science; Journal of Chromatography - A; 1148; 12-2007; 200-210 0021-9673 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.chroma.2007.03.018 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier Science |
publisher.none.fl_str_mv |
Elsevier Science |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1842981291018944512 |
score |
12.48226 |