- In this work we report a novel paper-based analytical device read-out via LED-induced fluorescence detection (FPAD) for the quantification of the emerging pollutant ethinylestradiol (EE2) in river water samples. The PAD was used as a reaction platform for a competitive enzyme immunoassay. For the PAD development, microzones of filter paper, printed by a wax printing method, were modified with amino-functionalized SBA-15 and subsequently, anti-EE2 specific antibodies were covalently immobilized. The determination of EE2 in water was carried out by adding a fixed concentration of EE2 conjugated with the enzyme horseradish peroxidase (HRP) to samples and standards. Then, the FPAD were added and incubated for 10 min. Finally, the detection was performed by the reaction of 10-acetyl-3,7-dihydroxyphenoxazine (ADHP) whose oxidation is catalyzed by HRP in the presence of H2O2, obtaining the highly fluorescent resorufin (R). Resorufin was detected by LED excitation at 550 nm, observing emission at 585 nm. The EE2 concentration in the samples was inversely proportional to the relative fluorescence obtained from the enzymatic reaction products. The FPAD assay showed a detection limit (LOD) of 0.05 ng L−1 and coefficients of variation (CV) below 4.5% within-assay and below 6.5% between-assay, respectively. The results obtained show the potential suitability of our FPAD for the selective and sensitive quantification of EE2 in river water samples. In addition, it has the PADs advantages of being disposable, easy to apply and inexpensive.
Fil: Scala Benuzzi, María Luz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Takara, Eduardo Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Alderete, Mara. Universidad Nacional de San Martin. Instituto de Nanosistemas; Argentina
Fil: Soler Illia, Galo Juan de Avila Arturo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martin. Instituto de Nanosistemas; Argentina
Fil: Schneider, Rudolf J.. Bundesanstalt für Materialforschung und -prüfung; Alemania
Fil: Raba, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Messina, Germán Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina - Materia
-
AMINO-FUNCTIONALIZED MESOPOROUS SILICA PARTICLES
ETHINYLESTRADIOL
LED-INDUCED FLUORESCENCE
PAPER BASED DEVICES - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
.jpg)
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/87352
Ver los metadatos del registro completo
| id |
CONICETDig_f337bcf32ed929280bbf6effd7d2b5d7 |
|---|---|
| oai_identifier_str |
oai:ri.conicet.gov.ar:11336/87352 |
| network_acronym_str |
CONICETDig |
| repository_id_str |
3498 |
| network_name_str |
CONICET Digital (CONICET) |
| spelling |
Ethinylestradiol quantification in drinking water sources using a fluorescent paper based immunosensorScala Benuzzi, María LuzTakara, Eduardo AndresAlderete, MaraSoler Illia, Galo Juan de Avila ArturoSchneider, Rudolf J.Raba, JulioMessina, Germán AlejandroAMINO-FUNCTIONALIZED MESOPOROUS SILICA PARTICLESETHINYLESTRADIOLLED-INDUCED FLUORESCENCEPAPER BASED DEVICEShttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1In this work we report a novel paper-based analytical device read-out via LED-induced fluorescence detection (FPAD) for the quantification of the emerging pollutant ethinylestradiol (EE2) in river water samples. The PAD was used as a reaction platform for a competitive enzyme immunoassay. For the PAD development, microzones of filter paper, printed by a wax printing method, were modified with amino-functionalized SBA-15 and subsequently, anti-EE2 specific antibodies were covalently immobilized. The determination of EE2 in water was carried out by adding a fixed concentration of EE2 conjugated with the enzyme horseradish peroxidase (HRP) to samples and standards. Then, the FPAD were added and incubated for 10 min. Finally, the detection was performed by the reaction of 10-acetyl-3,7-dihydroxyphenoxazine (ADHP) whose oxidation is catalyzed by HRP in the presence of H2O2, obtaining the highly fluorescent resorufin (R). Resorufin was detected by LED excitation at 550 nm, observing emission at 585 nm. The EE2 concentration in the samples was inversely proportional to the relative fluorescence obtained from the enzymatic reaction products. The FPAD assay showed a detection limit (LOD) of 0.05 ng L−1 and coefficients of variation (CV) below 4.5% within-assay and below 6.5% between-assay, respectively. The results obtained show the potential suitability of our FPAD for the selective and sensitive quantification of EE2 in river water samples. In addition, it has the PADs advantages of being disposable, easy to apply and inexpensive.Fil: Scala Benuzzi, María Luz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Takara, Eduardo Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Alderete, Mara. Universidad Nacional de San Martin. Instituto de Nanosistemas; ArgentinaFil: Soler Illia, Galo Juan de Avila Arturo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martin. Instituto de Nanosistemas; ArgentinaFil: Schneider, Rudolf J.. Bundesanstalt für Materialforschung und -prüfung; AlemaniaFil: Raba, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Messina, Germán Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaElsevier Science2018-09-21info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/87352Scala Benuzzi, María Luz; Takara, Eduardo Andres; Alderete, Mara; Soler Illia, Galo Juan de Avila Arturo; Schneider, Rudolf J.; et al.; Ethinylestradiol quantification in drinking water sources using a fluorescent paper based immunosensor; Elsevier Science; Microchemical Journal; 141; 21-9-2018; 287-2930026-265XCONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0026265X18303333info:eu-repo/semantics/altIdentifier/doi/10.1016/j.microc.2018.05.038info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2026-04-08T11:41:57Zoai:ri.conicet.gov.ar:11336/87352instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982026-04-08 11:41:58.052CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
| dc.title.none.fl_str_mv |
Ethinylestradiol quantification in drinking water sources using a fluorescent paper based immunosensor |
| title |
Ethinylestradiol quantification in drinking water sources using a fluorescent paper based immunosensor |
| spellingShingle |
Ethinylestradiol quantification in drinking water sources using a fluorescent paper based immunosensor Scala Benuzzi, María Luz AMINO-FUNCTIONALIZED MESOPOROUS SILICA PARTICLES ETHINYLESTRADIOL LED-INDUCED FLUORESCENCE PAPER BASED DEVICES |
| title_short |
Ethinylestradiol quantification in drinking water sources using a fluorescent paper based immunosensor |
| title_full |
Ethinylestradiol quantification in drinking water sources using a fluorescent paper based immunosensor |
| title_fullStr |
Ethinylestradiol quantification in drinking water sources using a fluorescent paper based immunosensor |
| title_full_unstemmed |
Ethinylestradiol quantification in drinking water sources using a fluorescent paper based immunosensor |
| title_sort |
Ethinylestradiol quantification in drinking water sources using a fluorescent paper based immunosensor |
| dc.creator.none.fl_str_mv |
Scala Benuzzi, María Luz Takara, Eduardo Andres Alderete, Mara Soler Illia, Galo Juan de Avila Arturo Schneider, Rudolf J. Raba, Julio Messina, Germán Alejandro |
| author |
Scala Benuzzi, María Luz |
| author_facet |
Scala Benuzzi, María Luz Takara, Eduardo Andres Alderete, Mara Soler Illia, Galo Juan de Avila Arturo Schneider, Rudolf J. Raba, Julio Messina, Germán Alejandro |
| author_role |
author |
| author2 |
Takara, Eduardo Andres Alderete, Mara Soler Illia, Galo Juan de Avila Arturo Schneider, Rudolf J. Raba, Julio Messina, Germán Alejandro |
| author2_role |
author author author author author author |
| dc.subject.none.fl_str_mv |
AMINO-FUNCTIONALIZED MESOPOROUS SILICA PARTICLES ETHINYLESTRADIOL LED-INDUCED FLUORESCENCE PAPER BASED DEVICES |
| topic |
AMINO-FUNCTIONALIZED MESOPOROUS SILICA PARTICLES ETHINYLESTRADIOL LED-INDUCED FLUORESCENCE PAPER BASED DEVICES |
| purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
| dc.description.none.fl_txt_mv |
In this work we report a novel paper-based analytical device read-out via LED-induced fluorescence detection (FPAD) for the quantification of the emerging pollutant ethinylestradiol (EE2) in river water samples. The PAD was used as a reaction platform for a competitive enzyme immunoassay. For the PAD development, microzones of filter paper, printed by a wax printing method, were modified with amino-functionalized SBA-15 and subsequently, anti-EE2 specific antibodies were covalently immobilized. The determination of EE2 in water was carried out by adding a fixed concentration of EE2 conjugated with the enzyme horseradish peroxidase (HRP) to samples and standards. Then, the FPAD were added and incubated for 10 min. Finally, the detection was performed by the reaction of 10-acetyl-3,7-dihydroxyphenoxazine (ADHP) whose oxidation is catalyzed by HRP in the presence of H2O2, obtaining the highly fluorescent resorufin (R). Resorufin was detected by LED excitation at 550 nm, observing emission at 585 nm. The EE2 concentration in the samples was inversely proportional to the relative fluorescence obtained from the enzymatic reaction products. The FPAD assay showed a detection limit (LOD) of 0.05 ng L−1 and coefficients of variation (CV) below 4.5% within-assay and below 6.5% between-assay, respectively. The results obtained show the potential suitability of our FPAD for the selective and sensitive quantification of EE2 in river water samples. In addition, it has the PADs advantages of being disposable, easy to apply and inexpensive. Fil: Scala Benuzzi, María Luz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina Fil: Takara, Eduardo Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina Fil: Alderete, Mara. Universidad Nacional de San Martin. Instituto de Nanosistemas; Argentina Fil: Soler Illia, Galo Juan de Avila Arturo. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martin. Instituto de Nanosistemas; Argentina Fil: Schneider, Rudolf J.. Bundesanstalt für Materialforschung und -prüfung; Alemania Fil: Raba, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina Fil: Messina, Germán Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina |
| description |
In this work we report a novel paper-based analytical device read-out via LED-induced fluorescence detection (FPAD) for the quantification of the emerging pollutant ethinylestradiol (EE2) in river water samples. The PAD was used as a reaction platform for a competitive enzyme immunoassay. For the PAD development, microzones of filter paper, printed by a wax printing method, were modified with amino-functionalized SBA-15 and subsequently, anti-EE2 specific antibodies were covalently immobilized. The determination of EE2 in water was carried out by adding a fixed concentration of EE2 conjugated with the enzyme horseradish peroxidase (HRP) to samples and standards. Then, the FPAD were added and incubated for 10 min. Finally, the detection was performed by the reaction of 10-acetyl-3,7-dihydroxyphenoxazine (ADHP) whose oxidation is catalyzed by HRP in the presence of H2O2, obtaining the highly fluorescent resorufin (R). Resorufin was detected by LED excitation at 550 nm, observing emission at 585 nm. The EE2 concentration in the samples was inversely proportional to the relative fluorescence obtained from the enzymatic reaction products. The FPAD assay showed a detection limit (LOD) of 0.05 ng L−1 and coefficients of variation (CV) below 4.5% within-assay and below 6.5% between-assay, respectively. The results obtained show the potential suitability of our FPAD for the selective and sensitive quantification of EE2 in river water samples. In addition, it has the PADs advantages of being disposable, easy to apply and inexpensive. |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018-09-21 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/87352 Scala Benuzzi, María Luz; Takara, Eduardo Andres; Alderete, Mara; Soler Illia, Galo Juan de Avila Arturo; Schneider, Rudolf J.; et al.; Ethinylestradiol quantification in drinking water sources using a fluorescent paper based immunosensor; Elsevier Science; Microchemical Journal; 141; 21-9-2018; 287-293 0026-265X CONICET Digital CONICET |
| url |
http://hdl.handle.net/11336/87352 |
| identifier_str_mv |
Scala Benuzzi, María Luz; Takara, Eduardo Andres; Alderete, Mara; Soler Illia, Galo Juan de Avila Arturo; Schneider, Rudolf J.; et al.; Ethinylestradiol quantification in drinking water sources using a fluorescent paper based immunosensor; Elsevier Science; Microchemical Journal; 141; 21-9-2018; 287-293 0026-265X CONICET Digital CONICET |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0026265X18303333 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.microc.2018.05.038 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier Science |
| publisher.none.fl_str_mv |
Elsevier Science |
| dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
| reponame_str |
CONICET Digital (CONICET) |
| collection |
CONICET Digital (CONICET) |
| instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
| _version_ |
1861931367595507712 |
| score |
13.09665 |