New Silver Nanosensor for Nickel Traces. Part II: Urinary Nickel Determination Associated to Smoking Addiction
- Autores
- Talio, María Carolina; Luconi, Marta Olga; Fernandez, Liliana Patricia
- Año de publicación
- 2012
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- A new fluorescence silver nanosensor assisted by surfactant has been recently synthesized and applied to ultra trace nickel determination. The methodology was validated by the standard addition method and satisfactorily applied to nickel determination in urine without previous treatment, coming from subjects with different smoking addiction levels and second hand smokers. Within-day precision was better than 0.011 CV. The reproducibility (between-days precision) was also evaluated over 3 days by performing six determinations each day with a CV of 0.025. The proposed methodology represents a promising approach in the area of biological monitoring due to its low operation cost, simplicity of instrumentation, high sampling speed and non-polluting solvents. Obtained results of urinary nickel concentration were successfully correlated with the tobacco addiction.
Fil: Talio, María Carolina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Luconi, M. O.. Universidad Nacional de San Luis; Argentina
Fil: Fernandez, Liliana Patricia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina - Materia
-
Fluorescence Nanosensor
Urinary Nickel
Smoker And Non-Smoker Subjects
Second Hand Smoke Exposure
Micellar Silver Nanoparticles - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/99758
Ver los metadatos del registro completo
id |
CONICETDig_c3c648c0693857c4a454ebd7c9974d67 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/99758 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
New Silver Nanosensor for Nickel Traces. Part II: Urinary Nickel Determination Associated to Smoking AddictionTalio, María CarolinaLuconi, Marta OlgaFernandez, Liliana PatriciaFluorescence NanosensorUrinary NickelSmoker And Non-Smoker SubjectsSecond Hand Smoke ExposureMicellar Silver Nanoparticleshttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1A new fluorescence silver nanosensor assisted by surfactant has been recently synthesized and applied to ultra trace nickel determination. The methodology was validated by the standard addition method and satisfactorily applied to nickel determination in urine without previous treatment, coming from subjects with different smoking addiction levels and second hand smokers. Within-day precision was better than 0.011 CV. The reproducibility (between-days precision) was also evaluated over 3 days by performing six determinations each day with a CV of 0.025. The proposed methodology represents a promising approach in the area of biological monitoring due to its low operation cost, simplicity of instrumentation, high sampling speed and non-polluting solvents. Obtained results of urinary nickel concentration were successfully correlated with the tobacco addiction.Fil: Talio, María Carolina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Luconi, M. O.. Universidad Nacional de San Luis; ArgentinaFil: Fernandez, Liliana Patricia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaDavid Publishing Company2012-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/rarapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/99758Talio, María Carolina; Luconi, Marta Olga; Fernandez, Liliana Patricia; New Silver Nanosensor for Nickel Traces. Part II: Urinary Nickel Determination Associated to Smoking Addiction ; David Publishing Company; Journal of Life Sciences; 6; 1; 1-2012; 36-401934-73911934-7405CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.semanticscholar.org/paper/New-Silver-Nanosensor-for-Nickel-Traces.-Part-II%3A-Mar%C4%B1%CC%81a-Talio/d30f5ddec1c79b3af0e1ebc56fe8ece19436a7e9info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:12:21Zoai:ri.conicet.gov.ar:11336/99758instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:12:22.208CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
New Silver Nanosensor for Nickel Traces. Part II: Urinary Nickel Determination Associated to Smoking Addiction |
title |
New Silver Nanosensor for Nickel Traces. Part II: Urinary Nickel Determination Associated to Smoking Addiction |
spellingShingle |
New Silver Nanosensor for Nickel Traces. Part II: Urinary Nickel Determination Associated to Smoking Addiction Talio, María Carolina Fluorescence Nanosensor Urinary Nickel Smoker And Non-Smoker Subjects Second Hand Smoke Exposure Micellar Silver Nanoparticles |
title_short |
New Silver Nanosensor for Nickel Traces. Part II: Urinary Nickel Determination Associated to Smoking Addiction |
title_full |
New Silver Nanosensor for Nickel Traces. Part II: Urinary Nickel Determination Associated to Smoking Addiction |
title_fullStr |
New Silver Nanosensor for Nickel Traces. Part II: Urinary Nickel Determination Associated to Smoking Addiction |
title_full_unstemmed |
New Silver Nanosensor for Nickel Traces. Part II: Urinary Nickel Determination Associated to Smoking Addiction |
title_sort |
New Silver Nanosensor for Nickel Traces. Part II: Urinary Nickel Determination Associated to Smoking Addiction |
dc.creator.none.fl_str_mv |
Talio, María Carolina Luconi, Marta Olga Fernandez, Liliana Patricia |
author |
Talio, María Carolina |
author_facet |
Talio, María Carolina Luconi, Marta Olga Fernandez, Liliana Patricia |
author_role |
author |
author2 |
Luconi, Marta Olga Fernandez, Liliana Patricia |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Fluorescence Nanosensor Urinary Nickel Smoker And Non-Smoker Subjects Second Hand Smoke Exposure Micellar Silver Nanoparticles |
topic |
Fluorescence Nanosensor Urinary Nickel Smoker And Non-Smoker Subjects Second Hand Smoke Exposure Micellar Silver Nanoparticles |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
A new fluorescence silver nanosensor assisted by surfactant has been recently synthesized and applied to ultra trace nickel determination. The methodology was validated by the standard addition method and satisfactorily applied to nickel determination in urine without previous treatment, coming from subjects with different smoking addiction levels and second hand smokers. Within-day precision was better than 0.011 CV. The reproducibility (between-days precision) was also evaluated over 3 days by performing six determinations each day with a CV of 0.025. The proposed methodology represents a promising approach in the area of biological monitoring due to its low operation cost, simplicity of instrumentation, high sampling speed and non-polluting solvents. Obtained results of urinary nickel concentration were successfully correlated with the tobacco addiction. Fil: Talio, María Carolina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina Fil: Luconi, M. O.. Universidad Nacional de San Luis; Argentina Fil: Fernandez, Liliana Patricia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina |
description |
A new fluorescence silver nanosensor assisted by surfactant has been recently synthesized and applied to ultra trace nickel determination. The methodology was validated by the standard addition method and satisfactorily applied to nickel determination in urine without previous treatment, coming from subjects with different smoking addiction levels and second hand smokers. Within-day precision was better than 0.011 CV. The reproducibility (between-days precision) was also evaluated over 3 days by performing six determinations each day with a CV of 0.025. The proposed methodology represents a promising approach in the area of biological monitoring due to its low operation cost, simplicity of instrumentation, high sampling speed and non-polluting solvents. Obtained results of urinary nickel concentration were successfully correlated with the tobacco addiction. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/99758 Talio, María Carolina; Luconi, Marta Olga; Fernandez, Liliana Patricia; New Silver Nanosensor for Nickel Traces. Part II: Urinary Nickel Determination Associated to Smoking Addiction ; David Publishing Company; Journal of Life Sciences; 6; 1; 1-2012; 36-40 1934-7391 1934-7405 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/99758 |
identifier_str_mv |
Talio, María Carolina; Luconi, Marta Olga; Fernandez, Liliana Patricia; New Silver Nanosensor for Nickel Traces. Part II: Urinary Nickel Determination Associated to Smoking Addiction ; David Publishing Company; Journal of Life Sciences; 6; 1; 1-2012; 36-40 1934-7391 1934-7405 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://www.semanticscholar.org/paper/New-Silver-Nanosensor-for-Nickel-Traces.-Part-II%3A-Mar%C4%B1%CC%81a-Talio/d30f5ddec1c79b3af0e1ebc56fe8ece19436a7e9 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/rar application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
David Publishing Company |
publisher.none.fl_str_mv |
David Publishing Company |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844614030318108672 |
score |
13.070432 |