Cadmium monitoring in saliva and urine as indicator of smoking addiction

Autores
Talio, María Carolina; Luconi, Marta Olga; Masi, Adriana Noemi; Fernandez, Liliana Patricia
Año de publicación
2010
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Cadmium is one of the many substances that may be acquired through active and passive smoking of tobacco. Saliva and urine are proposed for cadmium monitoring of non-smokers, second hand smokers, smokers and tobacco chewing appertaining to San Luis citizens without occupational exposition. Biological samples were collected by the same subjects, under strict proceeding instructions of sampling. Physical characteristics of samples were observed and checked with commercial test. Samples were analyzed using an adapted molecular fluorescence methodology with a previous extraction step. Stability of biological samples was daily studied for a period of one month. The method was successfully validated for accuracy, precision, linearity, specificity, and sensitivity. The simplicity and low coefficient of variance confirm the suitability of the method for urinary and salivary cadmium analyses. On the other side, the obtained results are in concordance with previous national epidemiological dates.
Fil: Talio, María Carolina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Luconi, Marta Olga. Universidad Nacional de San Luis; Argentina
Fil: Masi, Adriana Noemi. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Fernández, Liliana Patricia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Materia
MOLECULAR FLUORESCENCE
SALIVARY CADMIUM
SECOND HAND SMOKE EXPOSURE
SMOKER AND NON-SMOKER SUBJECTS
STABILITY TEST
URINARY CADMIUM
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/92840

id CONICETDig_54495de411513416ffdc3fe89d812681
oai_identifier_str oai:ri.conicet.gov.ar:11336/92840
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Cadmium monitoring in saliva and urine as indicator of smoking addictionTalio, María CarolinaLuconi, Marta OlgaMasi, Adriana NoemiFernandez, Liliana PatriciaMOLECULAR FLUORESCENCESALIVARY CADMIUMSECOND HAND SMOKE EXPOSURESMOKER AND NON-SMOKER SUBJECTSSTABILITY TESTURINARY CADMIUMhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1Cadmium is one of the many substances that may be acquired through active and passive smoking of tobacco. Saliva and urine are proposed for cadmium monitoring of non-smokers, second hand smokers, smokers and tobacco chewing appertaining to San Luis citizens without occupational exposition. Biological samples were collected by the same subjects, under strict proceeding instructions of sampling. Physical characteristics of samples were observed and checked with commercial test. Samples were analyzed using an adapted molecular fluorescence methodology with a previous extraction step. Stability of biological samples was daily studied for a period of one month. The method was successfully validated for accuracy, precision, linearity, specificity, and sensitivity. The simplicity and low coefficient of variance confirm the suitability of the method for urinary and salivary cadmium analyses. On the other side, the obtained results are in concordance with previous national epidemiological dates.Fil: Talio, María Carolina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Luconi, Marta Olga. Universidad Nacional de San Luis; ArgentinaFil: Masi, Adriana Noemi. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Fernández, Liliana Patricia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaElsevier Science2010-07-10info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/92840Talio, María Carolina; Luconi, Marta Olga; Masi, Adriana Noemi; Fernandez, Liliana Patricia; Cadmium monitoring in saliva and urine as indicator of smoking addiction; Elsevier Science; Science of the Total Environment; 408; 16; 10-7-2010; 3125-31320048-9697CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.scitotenv.2010.03.052info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0048969710003529info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:51:39Zoai:ri.conicet.gov.ar:11336/92840instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:51:40.245CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Cadmium monitoring in saliva and urine as indicator of smoking addiction
title Cadmium monitoring in saliva and urine as indicator of smoking addiction
spellingShingle Cadmium monitoring in saliva and urine as indicator of smoking addiction
Talio, María Carolina
MOLECULAR FLUORESCENCE
SALIVARY CADMIUM
SECOND HAND SMOKE EXPOSURE
SMOKER AND NON-SMOKER SUBJECTS
STABILITY TEST
URINARY CADMIUM
title_short Cadmium monitoring in saliva and urine as indicator of smoking addiction
title_full Cadmium monitoring in saliva and urine as indicator of smoking addiction
title_fullStr Cadmium monitoring in saliva and urine as indicator of smoking addiction
title_full_unstemmed Cadmium monitoring in saliva and urine as indicator of smoking addiction
title_sort Cadmium monitoring in saliva and urine as indicator of smoking addiction
dc.creator.none.fl_str_mv Talio, María Carolina
Luconi, Marta Olga
Masi, Adriana Noemi
Fernandez, Liliana Patricia
author Talio, María Carolina
author_facet Talio, María Carolina
Luconi, Marta Olga
Masi, Adriana Noemi
Fernandez, Liliana Patricia
author_role author
author2 Luconi, Marta Olga
Masi, Adriana Noemi
Fernandez, Liliana Patricia
author2_role author
author
author
dc.subject.none.fl_str_mv MOLECULAR FLUORESCENCE
SALIVARY CADMIUM
SECOND HAND SMOKE EXPOSURE
SMOKER AND NON-SMOKER SUBJECTS
STABILITY TEST
URINARY CADMIUM
topic MOLECULAR FLUORESCENCE
SALIVARY CADMIUM
SECOND HAND SMOKE EXPOSURE
SMOKER AND NON-SMOKER SUBJECTS
STABILITY TEST
URINARY CADMIUM
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.4
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv Cadmium is one of the many substances that may be acquired through active and passive smoking of tobacco. Saliva and urine are proposed for cadmium monitoring of non-smokers, second hand smokers, smokers and tobacco chewing appertaining to San Luis citizens without occupational exposition. Biological samples were collected by the same subjects, under strict proceeding instructions of sampling. Physical characteristics of samples were observed and checked with commercial test. Samples were analyzed using an adapted molecular fluorescence methodology with a previous extraction step. Stability of biological samples was daily studied for a period of one month. The method was successfully validated for accuracy, precision, linearity, specificity, and sensitivity. The simplicity and low coefficient of variance confirm the suitability of the method for urinary and salivary cadmium analyses. On the other side, the obtained results are in concordance with previous national epidemiological dates.
Fil: Talio, María Carolina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Luconi, Marta Olga. Universidad Nacional de San Luis; Argentina
Fil: Masi, Adriana Noemi. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Fernández, Liliana Patricia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
description Cadmium is one of the many substances that may be acquired through active and passive smoking of tobacco. Saliva and urine are proposed for cadmium monitoring of non-smokers, second hand smokers, smokers and tobacco chewing appertaining to San Luis citizens without occupational exposition. Biological samples were collected by the same subjects, under strict proceeding instructions of sampling. Physical characteristics of samples were observed and checked with commercial test. Samples were analyzed using an adapted molecular fluorescence methodology with a previous extraction step. Stability of biological samples was daily studied for a period of one month. The method was successfully validated for accuracy, precision, linearity, specificity, and sensitivity. The simplicity and low coefficient of variance confirm the suitability of the method for urinary and salivary cadmium analyses. On the other side, the obtained results are in concordance with previous national epidemiological dates.
publishDate 2010
dc.date.none.fl_str_mv 2010-07-10
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/92840
Talio, María Carolina; Luconi, Marta Olga; Masi, Adriana Noemi; Fernandez, Liliana Patricia; Cadmium monitoring in saliva and urine as indicator of smoking addiction; Elsevier Science; Science of the Total Environment; 408; 16; 10-7-2010; 3125-3132
0048-9697
CONICET Digital
CONICET
url http://hdl.handle.net/11336/92840
identifier_str_mv Talio, María Carolina; Luconi, Marta Olga; Masi, Adriana Noemi; Fernandez, Liliana Patricia; Cadmium monitoring in saliva and urine as indicator of smoking addiction; Elsevier Science; Science of the Total Environment; 408; 16; 10-7-2010; 3125-3132
0048-9697
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/10.1016/j.scitotenv.2010.03.052
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0048969710003529
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier Science
publisher.none.fl_str_mv Elsevier Science
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1842269109330378752
score 13.13397