Effectiveness of chlorination and ozonation methods on pure cultures of floc-forming micro-organisms and activated sludge: A comparative study
- Autores
- Caravelli, Alejandro Horacio; Giannuzzi, Leda; Zaritzky, Noemi Elisabet
- Año de publicación
- 2007
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Chlorination is a very useful control method of filamentous bulking in activated sludge systems; however, it favours formation of undesirable compounds such as trihalomethanes. Other oxidants, such as ozone, could be used for bulking control. In view of the fact that chlorine and ozone are both non-selective chemical agents affecting filamentous and floc-forming micro-organisms, the determination of optimum dosage conditions becomes essential to minimise the impact produced on the activated sludge process. In this work, the effects of chlorine and ozone on the biomass concentration of activated sludge and on different parameters that characterise the microbial metabolic activity were compared. The following techniques were applied: Respirometry (oxygen uptake rate); and INT-dehydrogenase activity test carried out both by spectrophotometry (DHAa) and image analysis (DHAi). The respirometric technique and the DHAa test quantified oxidants action on the total respiratory activity of flocs; the image DHAi test was applied to evaluate the specific action of the oxidants on filamentous micro-organisms. Additionally, plate count technique, respirometry and DHAa test were correlated using chlorine and ozone experiments on pure cultures of a floc-forming micro-organism (Acinetobacter anitratus) to compare the effect of the oxidising agents on the metabolic activity and the viability of the micro-organisms. Ozone was found to have more intense antimicrobial action. In activated sludge, ozone reduced total biomass concentration by oxidising various components and causing cell lysis. An equation was proposed to estimate biomass concentration of activated sludge as a function of time and ozone dose rate; in contrast, at the doses applied, chlorine did not reduce the concentration of activated sludge biomass. In activated sludge, adequate conditions for both oxidants were identified under which the respiratory activity of filamentous micro-organisms could be considerably inhibited, causing the lowest possible impact on whole floc metabolic activity. An initial chlorine dose of 7.9 mgCl2·gVSS-1 for a contact time of 5 min (initial pulse= 6.0 mgCl2·ℓ-1), and a total ozone dose of 66.0 mgO3·gVSS-1 (ozone dose rate of 3.3 mgO3·gVSS-1·min-1 for a contact time of 20 min) were the most suitable conditions to control filamentous bulking.
Fil: Caravelli, Alejandro Horacio. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; Argentina
Fil: Giannuzzi, Leda. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; Argentina
Fil: Zaritzky, Noemi Elisabet. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; Argentina. Universidad Nacional de La Plata. Facultad de Ingeniería. Departamento de Ingeniería Química; Argentina - Materia
-
Filamentous bulking
Chlorine, ozone
INT-dehydrogenase activity
Respirometry
Image analysis
Plate count - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/115898
Ver los metadatos del registro completo
id |
CONICETDig_b16b8b8961b2302100b66a6b8d9ad2c7 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/115898 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Effectiveness of chlorination and ozonation methods on pure cultures of floc-forming micro-organisms and activated sludge: A comparative studyCaravelli, Alejandro HoracioGiannuzzi, LedaZaritzky, Noemi ElisabetFilamentous bulkingChlorine, ozoneINT-dehydrogenase activityRespirometryImage analysisPlate counthttps://purl.org/becyt/ford/2.11https://purl.org/becyt/ford/2Chlorination is a very useful control method of filamentous bulking in activated sludge systems; however, it favours formation of undesirable compounds such as trihalomethanes. Other oxidants, such as ozone, could be used for bulking control. In view of the fact that chlorine and ozone are both non-selective chemical agents affecting filamentous and floc-forming micro-organisms, the determination of optimum dosage conditions becomes essential to minimise the impact produced on the activated sludge process. In this work, the effects of chlorine and ozone on the biomass concentration of activated sludge and on different parameters that characterise the microbial metabolic activity were compared. The following techniques were applied: Respirometry (oxygen uptake rate); and INT-dehydrogenase activity test carried out both by spectrophotometry (DHAa) and image analysis (DHAi). The respirometric technique and the DHAa test quantified oxidants action on the total respiratory activity of flocs; the image DHAi test was applied to evaluate the specific action of the oxidants on filamentous micro-organisms. Additionally, plate count technique, respirometry and DHAa test were correlated using chlorine and ozone experiments on pure cultures of a floc-forming micro-organism (Acinetobacter anitratus) to compare the effect of the oxidising agents on the metabolic activity and the viability of the micro-organisms. Ozone was found to have more intense antimicrobial action. In activated sludge, ozone reduced total biomass concentration by oxidising various components and causing cell lysis. An equation was proposed to estimate biomass concentration of activated sludge as a function of time and ozone dose rate; in contrast, at the doses applied, chlorine did not reduce the concentration of activated sludge biomass. In activated sludge, adequate conditions for both oxidants were identified under which the respiratory activity of filamentous micro-organisms could be considerably inhibited, causing the lowest possible impact on whole floc metabolic activity. An initial chlorine dose of 7.9 mgCl2·gVSS-1 for a contact time of 5 min (initial pulse= 6.0 mgCl2·ℓ-1), and a total ozone dose of 66.0 mgO3·gVSS-1 (ozone dose rate of 3.3 mgO3·gVSS-1·min-1 for a contact time of 20 min) were the most suitable conditions to control filamentous bulking.Fil: Caravelli, Alejandro Horacio. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; ArgentinaFil: Giannuzzi, Leda. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; ArgentinaFil: Zaritzky, Noemi Elisabet. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; Argentina. Universidad Nacional de La Plata. Facultad de Ingeniería. Departamento de Ingeniería Química; ArgentinaWater Research Commission2007-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/115898Caravelli, Alejandro Horacio; Giannuzzi, Leda; Zaritzky, Noemi Elisabet; Effectiveness of chlorination and ozonation methods on pure cultures of floc-forming micro-organisms and activated sludge: A comparative study; Water Research Commission; Water S.a.; 32; 4; 12-2007; 585-5950378-47381816-7950CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.4314/wsa.v32i4.5283info:eu-repo/semantics/altIdentifier/url/https://tinyurl.com/y4kq9zcfinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:06:12Zoai:ri.conicet.gov.ar:11336/115898instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:06:12.416CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Effectiveness of chlorination and ozonation methods on pure cultures of floc-forming micro-organisms and activated sludge: A comparative study |
title |
Effectiveness of chlorination and ozonation methods on pure cultures of floc-forming micro-organisms and activated sludge: A comparative study |
spellingShingle |
Effectiveness of chlorination and ozonation methods on pure cultures of floc-forming micro-organisms and activated sludge: A comparative study Caravelli, Alejandro Horacio Filamentous bulking Chlorine, ozone INT-dehydrogenase activity Respirometry Image analysis Plate count |
title_short |
Effectiveness of chlorination and ozonation methods on pure cultures of floc-forming micro-organisms and activated sludge: A comparative study |
title_full |
Effectiveness of chlorination and ozonation methods on pure cultures of floc-forming micro-organisms and activated sludge: A comparative study |
title_fullStr |
Effectiveness of chlorination and ozonation methods on pure cultures of floc-forming micro-organisms and activated sludge: A comparative study |
title_full_unstemmed |
Effectiveness of chlorination and ozonation methods on pure cultures of floc-forming micro-organisms and activated sludge: A comparative study |
title_sort |
Effectiveness of chlorination and ozonation methods on pure cultures of floc-forming micro-organisms and activated sludge: A comparative study |
dc.creator.none.fl_str_mv |
Caravelli, Alejandro Horacio Giannuzzi, Leda Zaritzky, Noemi Elisabet |
author |
Caravelli, Alejandro Horacio |
author_facet |
Caravelli, Alejandro Horacio Giannuzzi, Leda Zaritzky, Noemi Elisabet |
author_role |
author |
author2 |
Giannuzzi, Leda Zaritzky, Noemi Elisabet |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Filamentous bulking Chlorine, ozone INT-dehydrogenase activity Respirometry Image analysis Plate count |
topic |
Filamentous bulking Chlorine, ozone INT-dehydrogenase activity Respirometry Image analysis Plate count |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/2.11 https://purl.org/becyt/ford/2 |
dc.description.none.fl_txt_mv |
Chlorination is a very useful control method of filamentous bulking in activated sludge systems; however, it favours formation of undesirable compounds such as trihalomethanes. Other oxidants, such as ozone, could be used for bulking control. In view of the fact that chlorine and ozone are both non-selective chemical agents affecting filamentous and floc-forming micro-organisms, the determination of optimum dosage conditions becomes essential to minimise the impact produced on the activated sludge process. In this work, the effects of chlorine and ozone on the biomass concentration of activated sludge and on different parameters that characterise the microbial metabolic activity were compared. The following techniques were applied: Respirometry (oxygen uptake rate); and INT-dehydrogenase activity test carried out both by spectrophotometry (DHAa) and image analysis (DHAi). The respirometric technique and the DHAa test quantified oxidants action on the total respiratory activity of flocs; the image DHAi test was applied to evaluate the specific action of the oxidants on filamentous micro-organisms. Additionally, plate count technique, respirometry and DHAa test were correlated using chlorine and ozone experiments on pure cultures of a floc-forming micro-organism (Acinetobacter anitratus) to compare the effect of the oxidising agents on the metabolic activity and the viability of the micro-organisms. Ozone was found to have more intense antimicrobial action. In activated sludge, ozone reduced total biomass concentration by oxidising various components and causing cell lysis. An equation was proposed to estimate biomass concentration of activated sludge as a function of time and ozone dose rate; in contrast, at the doses applied, chlorine did not reduce the concentration of activated sludge biomass. In activated sludge, adequate conditions for both oxidants were identified under which the respiratory activity of filamentous micro-organisms could be considerably inhibited, causing the lowest possible impact on whole floc metabolic activity. An initial chlorine dose of 7.9 mgCl2·gVSS-1 for a contact time of 5 min (initial pulse= 6.0 mgCl2·ℓ-1), and a total ozone dose of 66.0 mgO3·gVSS-1 (ozone dose rate of 3.3 mgO3·gVSS-1·min-1 for a contact time of 20 min) were the most suitable conditions to control filamentous bulking. Fil: Caravelli, Alejandro Horacio. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; Argentina Fil: Giannuzzi, Leda. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; Argentina Fil: Zaritzky, Noemi Elisabet. Provincia de Buenos Aires. Gobernación. Comisión de Investigaciones Científicas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Centro de Investigación y Desarrollo en Criotecnología de Alimentos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Centro de Investigación y Desarrollo en Criotecnología de Alimentos; Argentina. Universidad Nacional de La Plata. Facultad de Ingeniería. Departamento de Ingeniería Química; Argentina |
description |
Chlorination is a very useful control method of filamentous bulking in activated sludge systems; however, it favours formation of undesirable compounds such as trihalomethanes. Other oxidants, such as ozone, could be used for bulking control. In view of the fact that chlorine and ozone are both non-selective chemical agents affecting filamentous and floc-forming micro-organisms, the determination of optimum dosage conditions becomes essential to minimise the impact produced on the activated sludge process. In this work, the effects of chlorine and ozone on the biomass concentration of activated sludge and on different parameters that characterise the microbial metabolic activity were compared. The following techniques were applied: Respirometry (oxygen uptake rate); and INT-dehydrogenase activity test carried out both by spectrophotometry (DHAa) and image analysis (DHAi). The respirometric technique and the DHAa test quantified oxidants action on the total respiratory activity of flocs; the image DHAi test was applied to evaluate the specific action of the oxidants on filamentous micro-organisms. Additionally, plate count technique, respirometry and DHAa test were correlated using chlorine and ozone experiments on pure cultures of a floc-forming micro-organism (Acinetobacter anitratus) to compare the effect of the oxidising agents on the metabolic activity and the viability of the micro-organisms. Ozone was found to have more intense antimicrobial action. In activated sludge, ozone reduced total biomass concentration by oxidising various components and causing cell lysis. An equation was proposed to estimate biomass concentration of activated sludge as a function of time and ozone dose rate; in contrast, at the doses applied, chlorine did not reduce the concentration of activated sludge biomass. In activated sludge, adequate conditions for both oxidants were identified under which the respiratory activity of filamentous micro-organisms could be considerably inhibited, causing the lowest possible impact on whole floc metabolic activity. An initial chlorine dose of 7.9 mgCl2·gVSS-1 for a contact time of 5 min (initial pulse= 6.0 mgCl2·ℓ-1), and a total ozone dose of 66.0 mgO3·gVSS-1 (ozone dose rate of 3.3 mgO3·gVSS-1·min-1 for a contact time of 20 min) were the most suitable conditions to control filamentous bulking. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-12 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/115898 Caravelli, Alejandro Horacio; Giannuzzi, Leda; Zaritzky, Noemi Elisabet; Effectiveness of chlorination and ozonation methods on pure cultures of floc-forming micro-organisms and activated sludge: A comparative study; Water Research Commission; Water S.a.; 32; 4; 12-2007; 585-595 0378-4738 1816-7950 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/115898 |
identifier_str_mv |
Caravelli, Alejandro Horacio; Giannuzzi, Leda; Zaritzky, Noemi Elisabet; Effectiveness of chlorination and ozonation methods on pure cultures of floc-forming micro-organisms and activated sludge: A comparative study; Water Research Commission; Water S.a.; 32; 4; 12-2007; 585-595 0378-4738 1816-7950 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.4314/wsa.v32i4.5283 info:eu-repo/semantics/altIdentifier/url/https://tinyurl.com/y4kq9zcf |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Water Research Commission |
publisher.none.fl_str_mv |
Water Research Commission |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844613907652542464 |
score |
13.070432 |