Preconcentration and post-column fluorescent derivatization for the environmental water monitoring of an antihelmintic macrocyclic drug used in livestock

Autores
Felici, Carlos Emiliano; Wang, Chien Chun; Casado, Cristian; Vicario, Ana Laura; Pereyra, Victor Daniel; Gomez, Maria Roxana Anabel
Año de publicación
2019
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
In this paper, a green analytical methodology based on fluorescence derivatization is proposed for the anti-helminthic drug monitoring ivermectin as environmental emergent contaminant. After sample clean-up, ivermectin was converted into a highly fluorescent derivative through a catalytic oxidation process followed by dehydration and tautomerization. Under optimal experimental conditions, a linear response was obtained for ivermectin within the range 0.38?600 μg L−1, with detection and quantification limits of 0.11 and 0.38 μg L−1, both values are lower than other previously reported. This method has been applied for ivermectin determination in environmental water samples at trace levels, showing its potential for contamination monitoring.
Fil: Felici, Carlos Emiliano. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Wang, Chien Chun. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Casado, Cristian. Provincia de Córdoba. Ministerio de Ciencia y Técnica. Centro de Excelencia en Productos y Procesos de Córdoba; Argentina
Fil: Vicario, Ana Laura. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Investigaciones en Tecnología Química. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Investigaciones en Tecnología Química; Argentina
Fil: Pereyra, Victor Daniel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Matemática Aplicada de San Luis "Prof. Ezio Marchi". Universidad Nacional de San Luis. Facultad de Ciencias Físico, Matemáticas y Naturales. Instituto de Matemática Aplicada de San Luis "Prof. Ezio Marchi"; Argentina
Fil: Gomez, Maria Roxana Anabel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Materia
ANALYTICAL CHEMISTRY
ENVIRONMENTAL POLLUTION
ENVIRONMENTAL SCIENCE
FLUORESCENT DERIVATIZATION
MACROCYCLIC LACTONE
WATER ANALYSIS
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/109484

id CONICETDig_a11e574c196dbbabbd9cc96173360534
oai_identifier_str oai:ri.conicet.gov.ar:11336/109484
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Preconcentration and post-column fluorescent derivatization for the environmental water monitoring of an antihelmintic macrocyclic drug used in livestockFelici, Carlos EmilianoWang, Chien ChunCasado, CristianVicario, Ana LauraPereyra, Victor DanielGomez, Maria Roxana AnabelANALYTICAL CHEMISTRYENVIRONMENTAL POLLUTIONENVIRONMENTAL SCIENCEFLUORESCENT DERIVATIZATIONMACROCYCLIC LACTONEWATER ANALYSIShttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1In this paper, a green analytical methodology based on fluorescence derivatization is proposed for the anti-helminthic drug monitoring ivermectin as environmental emergent contaminant. After sample clean-up, ivermectin was converted into a highly fluorescent derivative through a catalytic oxidation process followed by dehydration and tautomerization. Under optimal experimental conditions, a linear response was obtained for ivermectin within the range 0.38?600 μg L−1, with detection and quantification limits of 0.11 and 0.38 μg L−1, both values are lower than other previously reported. This method has been applied for ivermectin determination in environmental water samples at trace levels, showing its potential for contamination monitoring.Fil: Felici, Carlos Emiliano. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Wang, Chien Chun. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Casado, Cristian. Provincia de Córdoba. Ministerio de Ciencia y Técnica. Centro de Excelencia en Productos y Procesos de Córdoba; ArgentinaFil: Vicario, Ana Laura. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Investigaciones en Tecnología Química. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Investigaciones en Tecnología Química; ArgentinaFil: Pereyra, Victor Daniel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Matemática Aplicada de San Luis "Prof. Ezio Marchi". Universidad Nacional de San Luis. Facultad de Ciencias Físico, Matemáticas y Naturales. Instituto de Matemática Aplicada de San Luis "Prof. Ezio Marchi"; ArgentinaFil: Gomez, Maria Roxana Anabel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaElsevier2019-07info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/109484Felici, Carlos Emiliano; Wang, Chien Chun; Casado, Cristian; Vicario, Ana Laura; Pereyra, Victor Daniel; et al.; Preconcentration and post-column fluorescent derivatization for the environmental water monitoring of an antihelmintic macrocyclic drug used in livestock ; Elsevier; Heliyon; 5; 7; 7-2019; 1-7; e020252405-8440CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.heliyon.2019.e02025info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S2405844019356853info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:45:49Zoai:ri.conicet.gov.ar:11336/109484instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:45:49.914CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Preconcentration and post-column fluorescent derivatization for the environmental water monitoring of an antihelmintic macrocyclic drug used in livestock
title Preconcentration and post-column fluorescent derivatization for the environmental water monitoring of an antihelmintic macrocyclic drug used in livestock
spellingShingle Preconcentration and post-column fluorescent derivatization for the environmental water monitoring of an antihelmintic macrocyclic drug used in livestock
Felici, Carlos Emiliano
ANALYTICAL CHEMISTRY
ENVIRONMENTAL POLLUTION
ENVIRONMENTAL SCIENCE
FLUORESCENT DERIVATIZATION
MACROCYCLIC LACTONE
WATER ANALYSIS
title_short Preconcentration and post-column fluorescent derivatization for the environmental water monitoring of an antihelmintic macrocyclic drug used in livestock
title_full Preconcentration and post-column fluorescent derivatization for the environmental water monitoring of an antihelmintic macrocyclic drug used in livestock
title_fullStr Preconcentration and post-column fluorescent derivatization for the environmental water monitoring of an antihelmintic macrocyclic drug used in livestock
title_full_unstemmed Preconcentration and post-column fluorescent derivatization for the environmental water monitoring of an antihelmintic macrocyclic drug used in livestock
title_sort Preconcentration and post-column fluorescent derivatization for the environmental water monitoring of an antihelmintic macrocyclic drug used in livestock
dc.creator.none.fl_str_mv Felici, Carlos Emiliano
Wang, Chien Chun
Casado, Cristian
Vicario, Ana Laura
Pereyra, Victor Daniel
Gomez, Maria Roxana Anabel
author Felici, Carlos Emiliano
author_facet Felici, Carlos Emiliano
Wang, Chien Chun
Casado, Cristian
Vicario, Ana Laura
Pereyra, Victor Daniel
Gomez, Maria Roxana Anabel
author_role author
author2 Wang, Chien Chun
Casado, Cristian
Vicario, Ana Laura
Pereyra, Victor Daniel
Gomez, Maria Roxana Anabel
author2_role author
author
author
author
author
dc.subject.none.fl_str_mv ANALYTICAL CHEMISTRY
ENVIRONMENTAL POLLUTION
ENVIRONMENTAL SCIENCE
FLUORESCENT DERIVATIZATION
MACROCYCLIC LACTONE
WATER ANALYSIS
topic ANALYTICAL CHEMISTRY
ENVIRONMENTAL POLLUTION
ENVIRONMENTAL SCIENCE
FLUORESCENT DERIVATIZATION
MACROCYCLIC LACTONE
WATER ANALYSIS
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.4
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv In this paper, a green analytical methodology based on fluorescence derivatization is proposed for the anti-helminthic drug monitoring ivermectin as environmental emergent contaminant. After sample clean-up, ivermectin was converted into a highly fluorescent derivative through a catalytic oxidation process followed by dehydration and tautomerization. Under optimal experimental conditions, a linear response was obtained for ivermectin within the range 0.38?600 μg L−1, with detection and quantification limits of 0.11 and 0.38 μg L−1, both values are lower than other previously reported. This method has been applied for ivermectin determination in environmental water samples at trace levels, showing its potential for contamination monitoring.
Fil: Felici, Carlos Emiliano. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Wang, Chien Chun. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Casado, Cristian. Provincia de Córdoba. Ministerio de Ciencia y Técnica. Centro de Excelencia en Productos y Procesos de Córdoba; Argentina
Fil: Vicario, Ana Laura. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Investigaciones en Tecnología Química. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Investigaciones en Tecnología Química; Argentina
Fil: Pereyra, Victor Daniel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Matemática Aplicada de San Luis "Prof. Ezio Marchi". Universidad Nacional de San Luis. Facultad de Ciencias Físico, Matemáticas y Naturales. Instituto de Matemática Aplicada de San Luis "Prof. Ezio Marchi"; Argentina
Fil: Gomez, Maria Roxana Anabel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
description In this paper, a green analytical methodology based on fluorescence derivatization is proposed for the anti-helminthic drug monitoring ivermectin as environmental emergent contaminant. After sample clean-up, ivermectin was converted into a highly fluorescent derivative through a catalytic oxidation process followed by dehydration and tautomerization. Under optimal experimental conditions, a linear response was obtained for ivermectin within the range 0.38?600 μg L−1, with detection and quantification limits of 0.11 and 0.38 μg L−1, both values are lower than other previously reported. This method has been applied for ivermectin determination in environmental water samples at trace levels, showing its potential for contamination monitoring.
publishDate 2019
dc.date.none.fl_str_mv 2019-07
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/109484
Felici, Carlos Emiliano; Wang, Chien Chun; Casado, Cristian; Vicario, Ana Laura; Pereyra, Victor Daniel; et al.; Preconcentration and post-column fluorescent derivatization for the environmental water monitoring of an antihelmintic macrocyclic drug used in livestock ; Elsevier; Heliyon; 5; 7; 7-2019; 1-7; e02025
2405-8440
CONICET Digital
CONICET
url http://hdl.handle.net/11336/109484
identifier_str_mv Felici, Carlos Emiliano; Wang, Chien Chun; Casado, Cristian; Vicario, Ana Laura; Pereyra, Victor Daniel; et al.; Preconcentration and post-column fluorescent derivatization for the environmental water monitoring of an antihelmintic macrocyclic drug used in livestock ; Elsevier; Heliyon; 5; 7; 7-2019; 1-7; e02025
2405-8440
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/10.1016/j.heliyon.2019.e02025
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S2405844019356853
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1842268756424785920
score 13.13397