Determination of vanadium (V) in drinking water by flow injection and pre-concentration in a knotted reactor by inductively coupled plasma optical emission spectrometry with ultras...

Autores
Wuilloud, Rodolfo German; Salonia, José Antonio; Olsina, Roberto Antonio; Martinez, Luis Dante
Año de publicación
2000
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
An on-line vanadium pre-concentration and determination system implemented with inductively coupled plasma optical emission spectroscopy (ICP-OES) associated with a flow injection (FI) method with ultrasonic nebulization (USN) system was studied. The vanadium was retained as vanadium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol V(V)-(5-Br-PADAP) complex, at pH 3.2. The vanadium complex was removed from the knotted reactor (KR) with 30% v/v nitric acid. A sensitivity enhancement factor of 180 was obtained with respect to ICP-OES using pneumatic nebulization (15 for USN and 12 for KR). The value of detection limit for the pre-concentration of 10 ml of aqueous solution was 19 ng l-1. The precision for 10 replicate determinations at the 5 μg 1-1 V(V) level was 2.6% relative standard deviation (R.S.D.), calculated with the peak heights obtained. The calculation graph using the pre-concentration system for vanadium was linear with a correlation coefficient of 0.9995 at levels near the detection limits up to at least 100 μg l-1. The method was successfully applied to the determination of vanadium in drinking water samples.
Fil: Wuilloud, Rodolfo German. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Salonia, José Antonio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina
Fil: Olsina, Roberto Antonio. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Martinez, Luis Dante. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Materia
Vanadium determination
Drinking water
Inductively coupled plasma optical emission spectrometry
Ultrasonic nebulization
Knotted reactor2-(5-bromo-2-pyridylazo)-5-diethylaminophenol reagent
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/100712

id CONICETDig_98e898f54ef7a6a3cf102ca450135338
oai_identifier_str oai:ri.conicet.gov.ar:11336/100712
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Determination of vanadium (V) in drinking water by flow injection and pre-concentration in a knotted reactor by inductively coupled plasma optical emission spectrometry with ultrasonic nebulizationWuilloud, Rodolfo GermanSalonia, José AntonioOlsina, Roberto AntonioMartinez, Luis DanteVanadium determinationDrinking waterInductively coupled plasma optical emission spectrometryUltrasonic nebulizationKnotted reactor2-(5-bromo-2-pyridylazo)-5-diethylaminophenol reagenthttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1An on-line vanadium pre-concentration and determination system implemented with inductively coupled plasma optical emission spectroscopy (ICP-OES) associated with a flow injection (FI) method with ultrasonic nebulization (USN) system was studied. The vanadium was retained as vanadium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol V(V)-(5-Br-PADAP) complex, at pH 3.2. The vanadium complex was removed from the knotted reactor (KR) with 30% v/v nitric acid. A sensitivity enhancement factor of 180 was obtained with respect to ICP-OES using pneumatic nebulization (15 for USN and 12 for KR). The value of detection limit for the pre-concentration of 10 ml of aqueous solution was 19 ng l-1. The precision for 10 replicate determinations at the 5 μg 1-1 V(V) level was 2.6% relative standard deviation (R.S.D.), calculated with the peak heights obtained. The calculation graph using the pre-concentration system for vanadium was linear with a correlation coefficient of 0.9995 at levels near the detection limits up to at least 100 μg l-1. The method was successfully applied to the determination of vanadium in drinking water samples.Fil: Wuilloud, Rodolfo German. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Salonia, José Antonio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; ArgentinaFil: Olsina, Roberto Antonio. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Martinez, Luis Dante. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaPergamon-Elsevier Science Ltd2000-06info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/100712Wuilloud, Rodolfo German; Salonia, José Antonio; Olsina, Roberto Antonio; Martinez, Luis Dante; Determination of vanadium (V) in drinking water by flow injection and pre-concentration in a knotted reactor by inductively coupled plasma optical emission spectrometry with ultrasonic nebulization; Pergamon-Elsevier Science Ltd; Spectrochimica Acta Part B: Atomic Spectroscopy; 55; 6; 6-2000; 671-6800584-8547CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0584854700002159info:eu-repo/semantics/altIdentifier/doi/10.1016/S0584-8547(00)00215-9info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-15T14:21:19Zoai:ri.conicet.gov.ar:11336/100712instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-15 14:21:19.595CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Determination of vanadium (V) in drinking water by flow injection and pre-concentration in a knotted reactor by inductively coupled plasma optical emission spectrometry with ultrasonic nebulization
title Determination of vanadium (V) in drinking water by flow injection and pre-concentration in a knotted reactor by inductively coupled plasma optical emission spectrometry with ultrasonic nebulization
spellingShingle Determination of vanadium (V) in drinking water by flow injection and pre-concentration in a knotted reactor by inductively coupled plasma optical emission spectrometry with ultrasonic nebulization
Wuilloud, Rodolfo German
Vanadium determination
Drinking water
Inductively coupled plasma optical emission spectrometry
Ultrasonic nebulization
Knotted reactor2-(5-bromo-2-pyridylazo)-5-diethylaminophenol reagent
title_short Determination of vanadium (V) in drinking water by flow injection and pre-concentration in a knotted reactor by inductively coupled plasma optical emission spectrometry with ultrasonic nebulization
title_full Determination of vanadium (V) in drinking water by flow injection and pre-concentration in a knotted reactor by inductively coupled plasma optical emission spectrometry with ultrasonic nebulization
title_fullStr Determination of vanadium (V) in drinking water by flow injection and pre-concentration in a knotted reactor by inductively coupled plasma optical emission spectrometry with ultrasonic nebulization
title_full_unstemmed Determination of vanadium (V) in drinking water by flow injection and pre-concentration in a knotted reactor by inductively coupled plasma optical emission spectrometry with ultrasonic nebulization
title_sort Determination of vanadium (V) in drinking water by flow injection and pre-concentration in a knotted reactor by inductively coupled plasma optical emission spectrometry with ultrasonic nebulization
dc.creator.none.fl_str_mv Wuilloud, Rodolfo German
Salonia, José Antonio
Olsina, Roberto Antonio
Martinez, Luis Dante
author Wuilloud, Rodolfo German
author_facet Wuilloud, Rodolfo German
Salonia, José Antonio
Olsina, Roberto Antonio
Martinez, Luis Dante
author_role author
author2 Salonia, José Antonio
Olsina, Roberto Antonio
Martinez, Luis Dante
author2_role author
author
author
dc.subject.none.fl_str_mv Vanadium determination
Drinking water
Inductively coupled plasma optical emission spectrometry
Ultrasonic nebulization
Knotted reactor2-(5-bromo-2-pyridylazo)-5-diethylaminophenol reagent
topic Vanadium determination
Drinking water
Inductively coupled plasma optical emission spectrometry
Ultrasonic nebulization
Knotted reactor2-(5-bromo-2-pyridylazo)-5-diethylaminophenol reagent
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.4
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv An on-line vanadium pre-concentration and determination system implemented with inductively coupled plasma optical emission spectroscopy (ICP-OES) associated with a flow injection (FI) method with ultrasonic nebulization (USN) system was studied. The vanadium was retained as vanadium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol V(V)-(5-Br-PADAP) complex, at pH 3.2. The vanadium complex was removed from the knotted reactor (KR) with 30% v/v nitric acid. A sensitivity enhancement factor of 180 was obtained with respect to ICP-OES using pneumatic nebulization (15 for USN and 12 for KR). The value of detection limit for the pre-concentration of 10 ml of aqueous solution was 19 ng l-1. The precision for 10 replicate determinations at the 5 μg 1-1 V(V) level was 2.6% relative standard deviation (R.S.D.), calculated with the peak heights obtained. The calculation graph using the pre-concentration system for vanadium was linear with a correlation coefficient of 0.9995 at levels near the detection limits up to at least 100 μg l-1. The method was successfully applied to the determination of vanadium in drinking water samples.
Fil: Wuilloud, Rodolfo German. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Salonia, José Antonio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina
Fil: Olsina, Roberto Antonio. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Martinez, Luis Dante. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
description An on-line vanadium pre-concentration and determination system implemented with inductively coupled plasma optical emission spectroscopy (ICP-OES) associated with a flow injection (FI) method with ultrasonic nebulization (USN) system was studied. The vanadium was retained as vanadium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol V(V)-(5-Br-PADAP) complex, at pH 3.2. The vanadium complex was removed from the knotted reactor (KR) with 30% v/v nitric acid. A sensitivity enhancement factor of 180 was obtained with respect to ICP-OES using pneumatic nebulization (15 for USN and 12 for KR). The value of detection limit for the pre-concentration of 10 ml of aqueous solution was 19 ng l-1. The precision for 10 replicate determinations at the 5 μg 1-1 V(V) level was 2.6% relative standard deviation (R.S.D.), calculated with the peak heights obtained. The calculation graph using the pre-concentration system for vanadium was linear with a correlation coefficient of 0.9995 at levels near the detection limits up to at least 100 μg l-1. The method was successfully applied to the determination of vanadium in drinking water samples.
publishDate 2000
dc.date.none.fl_str_mv 2000-06
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/100712
Wuilloud, Rodolfo German; Salonia, José Antonio; Olsina, Roberto Antonio; Martinez, Luis Dante; Determination of vanadium (V) in drinking water by flow injection and pre-concentration in a knotted reactor by inductively coupled plasma optical emission spectrometry with ultrasonic nebulization; Pergamon-Elsevier Science Ltd; Spectrochimica Acta Part B: Atomic Spectroscopy; 55; 6; 6-2000; 671-680
0584-8547
CONICET Digital
CONICET
url http://hdl.handle.net/11336/100712
identifier_str_mv Wuilloud, Rodolfo German; Salonia, José Antonio; Olsina, Roberto Antonio; Martinez, Luis Dante; Determination of vanadium (V) in drinking water by flow injection and pre-concentration in a knotted reactor by inductively coupled plasma optical emission spectrometry with ultrasonic nebulization; Pergamon-Elsevier Science Ltd; Spectrochimica Acta Part B: Atomic Spectroscopy; 55; 6; 6-2000; 671-680
0584-8547
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0584854700002159
info:eu-repo/semantics/altIdentifier/doi/10.1016/S0584-8547(00)00215-9
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Pergamon-Elsevier Science Ltd
publisher.none.fl_str_mv Pergamon-Elsevier Science Ltd
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1846082600487092224
score 13.22299