On-line preconcentration and determination of chromium in parenteral solutions by flow injection - Flame atomic absorption spectrometry
- Autores
- Wuilloud, Gustavo M.; Wuilloud, Rodolfo German; Altamirano, Jorgelina Cecilia; Olsina, Roberto Antonio; Martinez, Luis Dante
- Año de publicación
- 2003
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- An on-line chromium preconcentration and determination system implemented with flame atomic absorption spectrometry (FAAS) associated to flow injection (FI) was studied. For the retention of chromium, 4-(2-Thiazolylazo)-resorcinol (TAR) and Amberlite XAD-16 were used, at pH 5.0. The Cr-TAR complex was removed from the micro-column with ethanol. An enrichment factor of 50 was obtained for the preconcentration of 50 ml of sample solution. The detection limit value for the preconcentration of 50 ml of aqueous solution of Cr was 20 ng l-1. The precision for ten replicate determinations at the 5 μg l-1 Cr levels was 2.9% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for chromium was linear with a correlation coefficient of 0.9997 at levels near the detection limits up to at least 100 μg l-1. The method was successfully applied to the determination of chromium in parenteral solution samples. © 2002 Elsevier Science B.V. All rights reserved.
Fil: Wuilloud, Gustavo M.. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; Argentina
Fil: Wuilloud, Rodolfo German. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Altamirano, Jorgelina Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; Argentina
Fil: Olsina, Roberto Antonio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Martinez, Luis Dante. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina - Materia
-
4-(2-THIAZOLYLAZO)-RESORCINOL
CHROMIUM IN PARENTERAL SOLUTIONS SAMPLES
FAAS
FLOW INJECTION
ON-LINE PRECONCENTRATION - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/99214
Ver los metadatos del registro completo
id |
CONICETDig_8d9e67641ced47a3409645d4c2dc1423 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/99214 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
On-line preconcentration and determination of chromium in parenteral solutions by flow injection - Flame atomic absorption spectrometryWuilloud, Gustavo M.Wuilloud, Rodolfo GermanAltamirano, Jorgelina CeciliaOlsina, Roberto AntonioMartinez, Luis Dante4-(2-THIAZOLYLAZO)-RESORCINOLCHROMIUM IN PARENTERAL SOLUTIONS SAMPLESFAASFLOW INJECTIONON-LINE PRECONCENTRATIONhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1An on-line chromium preconcentration and determination system implemented with flame atomic absorption spectrometry (FAAS) associated to flow injection (FI) was studied. For the retention of chromium, 4-(2-Thiazolylazo)-resorcinol (TAR) and Amberlite XAD-16 were used, at pH 5.0. The Cr-TAR complex was removed from the micro-column with ethanol. An enrichment factor of 50 was obtained for the preconcentration of 50 ml of sample solution. The detection limit value for the preconcentration of 50 ml of aqueous solution of Cr was 20 ng l-1. The precision for ten replicate determinations at the 5 μg l-1 Cr levels was 2.9% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for chromium was linear with a correlation coefficient of 0.9997 at levels near the detection limits up to at least 100 μg l-1. The method was successfully applied to the determination of chromium in parenteral solution samples. © 2002 Elsevier Science B.V. All rights reserved.Fil: Wuilloud, Gustavo M.. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; ArgentinaFil: Wuilloud, Rodolfo German. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Altamirano, Jorgelina Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; ArgentinaFil: Olsina, Roberto Antonio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Martinez, Luis Dante. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaElsevier Science2003-02info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/99214Wuilloud, Gustavo M.; Wuilloud, Rodolfo German; Altamirano, Jorgelina Cecilia; Olsina, Roberto Antonio; Martinez, Luis Dante; On-line preconcentration and determination of chromium in parenteral solutions by flow injection - Flame atomic absorption spectrometry; Elsevier Science; Journal of Pharmaceutical and Biomedical Analysis; 31; 1; 2-2003; 117-1240731-7085CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1016/S0731-7085(02)00604-0info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0731708502006040info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T10:04:16Zoai:ri.conicet.gov.ar:11336/99214instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 10:04:16.842CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
On-line preconcentration and determination of chromium in parenteral solutions by flow injection - Flame atomic absorption spectrometry |
title |
On-line preconcentration and determination of chromium in parenteral solutions by flow injection - Flame atomic absorption spectrometry |
spellingShingle |
On-line preconcentration and determination of chromium in parenteral solutions by flow injection - Flame atomic absorption spectrometry Wuilloud, Gustavo M. 4-(2-THIAZOLYLAZO)-RESORCINOL CHROMIUM IN PARENTERAL SOLUTIONS SAMPLES FAAS FLOW INJECTION ON-LINE PRECONCENTRATION |
title_short |
On-line preconcentration and determination of chromium in parenteral solutions by flow injection - Flame atomic absorption spectrometry |
title_full |
On-line preconcentration and determination of chromium in parenteral solutions by flow injection - Flame atomic absorption spectrometry |
title_fullStr |
On-line preconcentration and determination of chromium in parenteral solutions by flow injection - Flame atomic absorption spectrometry |
title_full_unstemmed |
On-line preconcentration and determination of chromium in parenteral solutions by flow injection - Flame atomic absorption spectrometry |
title_sort |
On-line preconcentration and determination of chromium in parenteral solutions by flow injection - Flame atomic absorption spectrometry |
dc.creator.none.fl_str_mv |
Wuilloud, Gustavo M. Wuilloud, Rodolfo German Altamirano, Jorgelina Cecilia Olsina, Roberto Antonio Martinez, Luis Dante |
author |
Wuilloud, Gustavo M. |
author_facet |
Wuilloud, Gustavo M. Wuilloud, Rodolfo German Altamirano, Jorgelina Cecilia Olsina, Roberto Antonio Martinez, Luis Dante |
author_role |
author |
author2 |
Wuilloud, Rodolfo German Altamirano, Jorgelina Cecilia Olsina, Roberto Antonio Martinez, Luis Dante |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
4-(2-THIAZOLYLAZO)-RESORCINOL CHROMIUM IN PARENTERAL SOLUTIONS SAMPLES FAAS FLOW INJECTION ON-LINE PRECONCENTRATION |
topic |
4-(2-THIAZOLYLAZO)-RESORCINOL CHROMIUM IN PARENTERAL SOLUTIONS SAMPLES FAAS FLOW INJECTION ON-LINE PRECONCENTRATION |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
An on-line chromium preconcentration and determination system implemented with flame atomic absorption spectrometry (FAAS) associated to flow injection (FI) was studied. For the retention of chromium, 4-(2-Thiazolylazo)-resorcinol (TAR) and Amberlite XAD-16 were used, at pH 5.0. The Cr-TAR complex was removed from the micro-column with ethanol. An enrichment factor of 50 was obtained for the preconcentration of 50 ml of sample solution. The detection limit value for the preconcentration of 50 ml of aqueous solution of Cr was 20 ng l-1. The precision for ten replicate determinations at the 5 μg l-1 Cr levels was 2.9% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for chromium was linear with a correlation coefficient of 0.9997 at levels near the detection limits up to at least 100 μg l-1. The method was successfully applied to the determination of chromium in parenteral solution samples. © 2002 Elsevier Science B.V. All rights reserved. Fil: Wuilloud, Gustavo M.. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; Argentina Fil: Wuilloud, Rodolfo German. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Altamirano, Jorgelina Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; Argentina Fil: Olsina, Roberto Antonio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina Fil: Martinez, Luis Dante. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina |
description |
An on-line chromium preconcentration and determination system implemented with flame atomic absorption spectrometry (FAAS) associated to flow injection (FI) was studied. For the retention of chromium, 4-(2-Thiazolylazo)-resorcinol (TAR) and Amberlite XAD-16 were used, at pH 5.0. The Cr-TAR complex was removed from the micro-column with ethanol. An enrichment factor of 50 was obtained for the preconcentration of 50 ml of sample solution. The detection limit value for the preconcentration of 50 ml of aqueous solution of Cr was 20 ng l-1. The precision for ten replicate determinations at the 5 μg l-1 Cr levels was 2.9% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for chromium was linear with a correlation coefficient of 0.9997 at levels near the detection limits up to at least 100 μg l-1. The method was successfully applied to the determination of chromium in parenteral solution samples. © 2002 Elsevier Science B.V. All rights reserved. |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003-02 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/99214 Wuilloud, Gustavo M.; Wuilloud, Rodolfo German; Altamirano, Jorgelina Cecilia; Olsina, Roberto Antonio; Martinez, Luis Dante; On-line preconcentration and determination of chromium in parenteral solutions by flow injection - Flame atomic absorption spectrometry; Elsevier Science; Journal of Pharmaceutical and Biomedical Analysis; 31; 1; 2-2003; 117-124 0731-7085 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/99214 |
identifier_str_mv |
Wuilloud, Gustavo M.; Wuilloud, Rodolfo German; Altamirano, Jorgelina Cecilia; Olsina, Roberto Antonio; Martinez, Luis Dante; On-line preconcentration and determination of chromium in parenteral solutions by flow injection - Flame atomic absorption spectrometry; Elsevier Science; Journal of Pharmaceutical and Biomedical Analysis; 31; 1; 2-2003; 117-124 0731-7085 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.1016/S0731-7085(02)00604-0 info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0731708502006040 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier Science |
publisher.none.fl_str_mv |
Elsevier Science |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1842269848272371712 |
score |
13.13397 |