Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS
- Autores
- Wuilloud, Rodolfo German; Wuilloud, Gustavo M.; Altamirano, Jorgelina Cecilia; Olsina, Roberto Antonio; Martinez, Luis Dante
- Año de publicación
- 2002
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- A method for the pre-concentration and speciation of chromium was developed. On-line pre-concentration and determination were obtained using flame atomic absorption spectrometry (FAAS) coupled with flow injection (FI). To determine the total chromium present in water samples, the chromium species were retained on an Amberlite XAD-16 resin as chromium-4-(2-Thiazolylazo)-resorcinol (Cr-TAR) complex, at pH 5.0. On the other hand, Cr(VI) was determined by selective formation of Cr-TAR complexes with the use of 1,2 cyclohexane-diaminetetracetic acid (CDTA) as masking agent of Cr(III). The Cr-TAR complexes were formed by heating the reagents at 90?C for 50 minutes and then retained on the resin. The Cr-TAR complexes were removed from the micro-column with ethanol. The Cr(III) concentration was determined by the difference between the total chromium concentration and that of Cr(VI). A sensitivity enhancement factor of 250 was obtained with respect to the chromium determination in aqueous medium by FAAS (50 for pre-concentration and 5 due to the use of ethanol as solvent). The detection limit for the pre-concentration of 50 mL of aqueous solution was 20 ng/L. The precision for 10 replicate determinations at the 2.0-?g/L Cr level was 3.8% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the separation and pre-concentration method for chromium species was linear with a correlation coefficient of 0.9994 at levels near the detection limits up to at least 100 ?g/L. The method was successfully applied to the speciation of chromium in water samples.
Fil: Wuilloud, Rodolfo German. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Wuilloud, Gustavo M.. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina
Fil: Altamirano, Jorgelina Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina
Fil: Olsina, Roberto Antonio. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
Fil: Martinez, Luis Dante. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina - Materia
-
PRECONCENTRATION CHROMIUM
SPECIATION CHROMIUM
ATOMIC ABSORTION SPECTROMETRY (FAAS) - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/103116
Ver los metadatos del registro completo
id |
CONICETDig_c4f0a09a97f20c85bb922a5565045cff |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/103116 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AASWuilloud, Rodolfo GermanWuilloud, Gustavo M.Altamirano, Jorgelina CeciliaOlsina, Roberto AntonioMartinez, Luis DantePRECONCENTRATION CHROMIUMSPECIATION CHROMIUMATOMIC ABSORTION SPECTROMETRY (FAAS)https://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1A method for the pre-concentration and speciation of chromium was developed. On-line pre-concentration and determination were obtained using flame atomic absorption spectrometry (FAAS) coupled with flow injection (FI). To determine the total chromium present in water samples, the chromium species were retained on an Amberlite XAD-16 resin as chromium-4-(2-Thiazolylazo)-resorcinol (Cr-TAR) complex, at pH 5.0. On the other hand, Cr(VI) was determined by selective formation of Cr-TAR complexes with the use of 1,2 cyclohexane-diaminetetracetic acid (CDTA) as masking agent of Cr(III). The Cr-TAR complexes were formed by heating the reagents at 90?C for 50 minutes and then retained on the resin. The Cr-TAR complexes were removed from the micro-column with ethanol. The Cr(III) concentration was determined by the difference between the total chromium concentration and that of Cr(VI). A sensitivity enhancement factor of 250 was obtained with respect to the chromium determination in aqueous medium by FAAS (50 for pre-concentration and 5 due to the use of ethanol as solvent). The detection limit for the pre-concentration of 50 mL of aqueous solution was 20 ng/L. The precision for 10 replicate determinations at the 2.0-?g/L Cr level was 3.8% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the separation and pre-concentration method for chromium species was linear with a correlation coefficient of 0.9994 at levels near the detection limits up to at least 100 ?g/L. The method was successfully applied to the speciation of chromium in water samples.Fil: Wuilloud, Rodolfo German. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Wuilloud, Gustavo M.. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; ArgentinaFil: Altamirano, Jorgelina Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; ArgentinaFil: Olsina, Roberto Antonio. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaFil: Martinez, Luis Dante. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; ArgentinaPerkin-Elmer Corporation2002-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/103116Wuilloud, Rodolfo German; Wuilloud, Gustavo M.; Altamirano, Jorgelina Cecilia; Olsina, Roberto Antonio; Martinez, Luis Dante; Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS; Perkin-Elmer Corporation; Atomic Spectroscopy; 23; 2; 3-2002; 44-510195-5373CONICET DigitalCONICETenginfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:50:54Zoai:ri.conicet.gov.ar:11336/103116instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:50:54.424CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS |
title |
Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS |
spellingShingle |
Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS Wuilloud, Rodolfo German PRECONCENTRATION CHROMIUM SPECIATION CHROMIUM ATOMIC ABSORTION SPECTROMETRY (FAAS) |
title_short |
Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS |
title_full |
Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS |
title_fullStr |
Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS |
title_full_unstemmed |
Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS |
title_sort |
Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS |
dc.creator.none.fl_str_mv |
Wuilloud, Rodolfo German Wuilloud, Gustavo M. Altamirano, Jorgelina Cecilia Olsina, Roberto Antonio Martinez, Luis Dante |
author |
Wuilloud, Rodolfo German |
author_facet |
Wuilloud, Rodolfo German Wuilloud, Gustavo M. Altamirano, Jorgelina Cecilia Olsina, Roberto Antonio Martinez, Luis Dante |
author_role |
author |
author2 |
Wuilloud, Gustavo M. Altamirano, Jorgelina Cecilia Olsina, Roberto Antonio Martinez, Luis Dante |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
PRECONCENTRATION CHROMIUM SPECIATION CHROMIUM ATOMIC ABSORTION SPECTROMETRY (FAAS) |
topic |
PRECONCENTRATION CHROMIUM SPECIATION CHROMIUM ATOMIC ABSORTION SPECTROMETRY (FAAS) |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
A method for the pre-concentration and speciation of chromium was developed. On-line pre-concentration and determination were obtained using flame atomic absorption spectrometry (FAAS) coupled with flow injection (FI). To determine the total chromium present in water samples, the chromium species were retained on an Amberlite XAD-16 resin as chromium-4-(2-Thiazolylazo)-resorcinol (Cr-TAR) complex, at pH 5.0. On the other hand, Cr(VI) was determined by selective formation of Cr-TAR complexes with the use of 1,2 cyclohexane-diaminetetracetic acid (CDTA) as masking agent of Cr(III). The Cr-TAR complexes were formed by heating the reagents at 90?C for 50 minutes and then retained on the resin. The Cr-TAR complexes were removed from the micro-column with ethanol. The Cr(III) concentration was determined by the difference between the total chromium concentration and that of Cr(VI). A sensitivity enhancement factor of 250 was obtained with respect to the chromium determination in aqueous medium by FAAS (50 for pre-concentration and 5 due to the use of ethanol as solvent). The detection limit for the pre-concentration of 50 mL of aqueous solution was 20 ng/L. The precision for 10 replicate determinations at the 2.0-?g/L Cr level was 3.8% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the separation and pre-concentration method for chromium species was linear with a correlation coefficient of 0.9994 at levels near the detection limits up to at least 100 ?g/L. The method was successfully applied to the speciation of chromium in water samples. Fil: Wuilloud, Rodolfo German. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Wuilloud, Gustavo M.. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina Fil: Altamirano, Jorgelina Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina Fil: Olsina, Roberto Antonio. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina Fil: Martinez, Luis Dante. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina |
description |
A method for the pre-concentration and speciation of chromium was developed. On-line pre-concentration and determination were obtained using flame atomic absorption spectrometry (FAAS) coupled with flow injection (FI). To determine the total chromium present in water samples, the chromium species were retained on an Amberlite XAD-16 resin as chromium-4-(2-Thiazolylazo)-resorcinol (Cr-TAR) complex, at pH 5.0. On the other hand, Cr(VI) was determined by selective formation of Cr-TAR complexes with the use of 1,2 cyclohexane-diaminetetracetic acid (CDTA) as masking agent of Cr(III). The Cr-TAR complexes were formed by heating the reagents at 90?C for 50 minutes and then retained on the resin. The Cr-TAR complexes were removed from the micro-column with ethanol. The Cr(III) concentration was determined by the difference between the total chromium concentration and that of Cr(VI). A sensitivity enhancement factor of 250 was obtained with respect to the chromium determination in aqueous medium by FAAS (50 for pre-concentration and 5 due to the use of ethanol as solvent). The detection limit for the pre-concentration of 50 mL of aqueous solution was 20 ng/L. The precision for 10 replicate determinations at the 2.0-?g/L Cr level was 3.8% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the separation and pre-concentration method for chromium species was linear with a correlation coefficient of 0.9994 at levels near the detection limits up to at least 100 ?g/L. The method was successfully applied to the speciation of chromium in water samples. |
publishDate |
2002 |
dc.date.none.fl_str_mv |
2002-03 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/103116 Wuilloud, Rodolfo German; Wuilloud, Gustavo M.; Altamirano, Jorgelina Cecilia; Olsina, Roberto Antonio; Martinez, Luis Dante; Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS; Perkin-Elmer Corporation; Atomic Spectroscopy; 23; 2; 3-2002; 44-51 0195-5373 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/103116 |
identifier_str_mv |
Wuilloud, Rodolfo German; Wuilloud, Gustavo M.; Altamirano, Jorgelina Cecilia; Olsina, Roberto Antonio; Martinez, Luis Dante; Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS; Perkin-Elmer Corporation; Atomic Spectroscopy; 23; 2; 3-2002; 44-51 0195-5373 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Perkin-Elmer Corporation |
publisher.none.fl_str_mv |
Perkin-Elmer Corporation |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1842269060570546176 |
score |
13.13397 |