Biodistribution of GB-10 (Na2 10B10H10) compound for boron neutron capture therapy (BNCT) in an experimental model of oral cancer in the hamster cheek pouch
- Autores
- Heber, Elisa Mercedes; Trivillin, Verónica Andrea; Nigg, David; Kreimann, Erica Lorena; Itoiz, María Elina; Jiménez Rebagliati, Raúl Alberto Jorge; Batistoni, Daniel Alberto; Schwint, Amanda Elena
- Año de publicación
- 2004
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Objective: We previously proposed the hamster cheek pouch model of oral cancer for BNCT studies. We herein present the biodistribution of a non-toxic boron compound, GB-10 (Na210B10H10), in this model to assess its potential for BNCT or BNCT enhanced Fast Neutron Therapy. Materials and methods: We evaluated the uptake and retention of GB-10 in tumour and precancerous tissue and in potentially dose-limiting, clinically relevant normal tissues. Results: Mean tumour boron concentration delivered by GB-10 (50mgB/kg) peaked to 77.7±28.0ppm at 20min post-administration and remained at therapeutically useful values of 31.9±21.4ppm at 3h. The clearance rate for normal tissues was faster than for tumour tissue. The consistently low brain and spinal cord values would preclude normal tissue toxicity. The uptake of GB-10 by precancerous tissue may be of potential use in the treatment of field cancerized areas. GB-10 was deposited homogeneously in different tumour areas, an asset when treating heterogenous tumours. The data suggests that the joint administration of BPA and GB-10 may improve the therapeutic efficacy of BNCT. Conclusions: GB-10 is a potential boron carrier for BNCT of head and neck tumours and for BNCT-FNT.
Fil: Heber, Elisa Mercedes. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; Argentina
Fil: Trivillin, Verónica Andrea. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; Argentina
Fil: Nigg, David. Idaho National Engineering and Environmental Laboratory; Estados Unidos
Fil: Kreimann, Erica Lorena. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; Argentina
Fil: Itoiz, María Elina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; Argentina. Universidad de Buenos Aires. Facultad de Odontología; Argentina
Fil: Jiménez Rebagliati, Raúl Alberto Jorge. Comisión Nacional de Energía Atómica; Argentina
Fil: Batistoni, Daniel Alberto. Comisión Nacional de Energía Atómica; Argentina
Fil: Schwint, Amanda Elena. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; Argentina - Materia
-
BNCT
GB-10
HAMSTER CHEEK POUCH
ORAL CANCER - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/162651
Ver los metadatos del registro completo
id |
CONICETDig_8738bd63c737767f4c6bad8557e537cb |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/162651 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Biodistribution of GB-10 (Na2 10B10H10) compound for boron neutron capture therapy (BNCT) in an experimental model of oral cancer in the hamster cheek pouchHeber, Elisa MercedesTrivillin, Verónica AndreaNigg, DavidKreimann, Erica LorenaItoiz, María ElinaJiménez Rebagliati, Raúl Alberto JorgeBatistoni, Daniel AlbertoSchwint, Amanda ElenaBNCTGB-10HAMSTER CHEEK POUCHORAL CANCERhttps://purl.org/becyt/ford/1.6https://purl.org/becyt/ford/1Objective: We previously proposed the hamster cheek pouch model of oral cancer for BNCT studies. We herein present the biodistribution of a non-toxic boron compound, GB-10 (Na210B10H10), in this model to assess its potential for BNCT or BNCT enhanced Fast Neutron Therapy. Materials and methods: We evaluated the uptake and retention of GB-10 in tumour and precancerous tissue and in potentially dose-limiting, clinically relevant normal tissues. Results: Mean tumour boron concentration delivered by GB-10 (50mgB/kg) peaked to 77.7±28.0ppm at 20min post-administration and remained at therapeutically useful values of 31.9±21.4ppm at 3h. The clearance rate for normal tissues was faster than for tumour tissue. The consistently low brain and spinal cord values would preclude normal tissue toxicity. The uptake of GB-10 by precancerous tissue may be of potential use in the treatment of field cancerized areas. GB-10 was deposited homogeneously in different tumour areas, an asset when treating heterogenous tumours. The data suggests that the joint administration of BPA and GB-10 may improve the therapeutic efficacy of BNCT. Conclusions: GB-10 is a potential boron carrier for BNCT of head and neck tumours and for BNCT-FNT.Fil: Heber, Elisa Mercedes. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; ArgentinaFil: Trivillin, Verónica Andrea. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; ArgentinaFil: Nigg, David. Idaho National Engineering and Environmental Laboratory; Estados UnidosFil: Kreimann, Erica Lorena. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; ArgentinaFil: Itoiz, María Elina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; Argentina. Universidad de Buenos Aires. Facultad de Odontología; ArgentinaFil: Jiménez Rebagliati, Raúl Alberto Jorge. Comisión Nacional de Energía Atómica; ArgentinaFil: Batistoni, Daniel Alberto. Comisión Nacional de Energía Atómica; ArgentinaFil: Schwint, Amanda Elena. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; ArgentinaElsevier2004-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/162651Heber, Elisa Mercedes; Trivillin, Verónica Andrea; Nigg, David; Kreimann, Erica Lorena; Itoiz, María Elina; et al.; Biodistribution of GB-10 (Na2 10B10H10) compound for boron neutron capture therapy (BNCT) in an experimental model of oral cancer in the hamster cheek pouch; Elsevier; Archives of Oral Biology; 49; 4; 12-2004; 313-3240003-9969CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0003996903002632info:eu-repo/semantics/altIdentifier/doi/10.1016/j.archoralbio.2003.10.003info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:55:42Zoai:ri.conicet.gov.ar:11336/162651instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:55:43.074CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Biodistribution of GB-10 (Na2 10B10H10) compound for boron neutron capture therapy (BNCT) in an experimental model of oral cancer in the hamster cheek pouch |
title |
Biodistribution of GB-10 (Na2 10B10H10) compound for boron neutron capture therapy (BNCT) in an experimental model of oral cancer in the hamster cheek pouch |
spellingShingle |
Biodistribution of GB-10 (Na2 10B10H10) compound for boron neutron capture therapy (BNCT) in an experimental model of oral cancer in the hamster cheek pouch Heber, Elisa Mercedes BNCT GB-10 HAMSTER CHEEK POUCH ORAL CANCER |
title_short |
Biodistribution of GB-10 (Na2 10B10H10) compound for boron neutron capture therapy (BNCT) in an experimental model of oral cancer in the hamster cheek pouch |
title_full |
Biodistribution of GB-10 (Na2 10B10H10) compound for boron neutron capture therapy (BNCT) in an experimental model of oral cancer in the hamster cheek pouch |
title_fullStr |
Biodistribution of GB-10 (Na2 10B10H10) compound for boron neutron capture therapy (BNCT) in an experimental model of oral cancer in the hamster cheek pouch |
title_full_unstemmed |
Biodistribution of GB-10 (Na2 10B10H10) compound for boron neutron capture therapy (BNCT) in an experimental model of oral cancer in the hamster cheek pouch |
title_sort |
Biodistribution of GB-10 (Na2 10B10H10) compound for boron neutron capture therapy (BNCT) in an experimental model of oral cancer in the hamster cheek pouch |
dc.creator.none.fl_str_mv |
Heber, Elisa Mercedes Trivillin, Verónica Andrea Nigg, David Kreimann, Erica Lorena Itoiz, María Elina Jiménez Rebagliati, Raúl Alberto Jorge Batistoni, Daniel Alberto Schwint, Amanda Elena |
author |
Heber, Elisa Mercedes |
author_facet |
Heber, Elisa Mercedes Trivillin, Verónica Andrea Nigg, David Kreimann, Erica Lorena Itoiz, María Elina Jiménez Rebagliati, Raúl Alberto Jorge Batistoni, Daniel Alberto Schwint, Amanda Elena |
author_role |
author |
author2 |
Trivillin, Verónica Andrea Nigg, David Kreimann, Erica Lorena Itoiz, María Elina Jiménez Rebagliati, Raúl Alberto Jorge Batistoni, Daniel Alberto Schwint, Amanda Elena |
author2_role |
author author author author author author author |
dc.subject.none.fl_str_mv |
BNCT GB-10 HAMSTER CHEEK POUCH ORAL CANCER |
topic |
BNCT GB-10 HAMSTER CHEEK POUCH ORAL CANCER |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.6 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
Objective: We previously proposed the hamster cheek pouch model of oral cancer for BNCT studies. We herein present the biodistribution of a non-toxic boron compound, GB-10 (Na210B10H10), in this model to assess its potential for BNCT or BNCT enhanced Fast Neutron Therapy. Materials and methods: We evaluated the uptake and retention of GB-10 in tumour and precancerous tissue and in potentially dose-limiting, clinically relevant normal tissues. Results: Mean tumour boron concentration delivered by GB-10 (50mgB/kg) peaked to 77.7±28.0ppm at 20min post-administration and remained at therapeutically useful values of 31.9±21.4ppm at 3h. The clearance rate for normal tissues was faster than for tumour tissue. The consistently low brain and spinal cord values would preclude normal tissue toxicity. The uptake of GB-10 by precancerous tissue may be of potential use in the treatment of field cancerized areas. GB-10 was deposited homogeneously in different tumour areas, an asset when treating heterogenous tumours. The data suggests that the joint administration of BPA and GB-10 may improve the therapeutic efficacy of BNCT. Conclusions: GB-10 is a potential boron carrier for BNCT of head and neck tumours and for BNCT-FNT. Fil: Heber, Elisa Mercedes. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; Argentina Fil: Trivillin, Verónica Andrea. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; Argentina Fil: Nigg, David. Idaho National Engineering and Environmental Laboratory; Estados Unidos Fil: Kreimann, Erica Lorena. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; Argentina Fil: Itoiz, María Elina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; Argentina. Universidad de Buenos Aires. Facultad de Odontología; Argentina Fil: Jiménez Rebagliati, Raúl Alberto Jorge. Comisión Nacional de Energía Atómica; Argentina Fil: Batistoni, Daniel Alberto. Comisión Nacional de Energía Atómica; Argentina Fil: Schwint, Amanda Elena. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Aplicaciones de la Tecnología Nuclear. Departamento de Radiobiología; Argentina |
description |
Objective: We previously proposed the hamster cheek pouch model of oral cancer for BNCT studies. We herein present the biodistribution of a non-toxic boron compound, GB-10 (Na210B10H10), in this model to assess its potential for BNCT or BNCT enhanced Fast Neutron Therapy. Materials and methods: We evaluated the uptake and retention of GB-10 in tumour and precancerous tissue and in potentially dose-limiting, clinically relevant normal tissues. Results: Mean tumour boron concentration delivered by GB-10 (50mgB/kg) peaked to 77.7±28.0ppm at 20min post-administration and remained at therapeutically useful values of 31.9±21.4ppm at 3h. The clearance rate for normal tissues was faster than for tumour tissue. The consistently low brain and spinal cord values would preclude normal tissue toxicity. The uptake of GB-10 by precancerous tissue may be of potential use in the treatment of field cancerized areas. GB-10 was deposited homogeneously in different tumour areas, an asset when treating heterogenous tumours. The data suggests that the joint administration of BPA and GB-10 may improve the therapeutic efficacy of BNCT. Conclusions: GB-10 is a potential boron carrier for BNCT of head and neck tumours and for BNCT-FNT. |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004-12 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/162651 Heber, Elisa Mercedes; Trivillin, Verónica Andrea; Nigg, David; Kreimann, Erica Lorena; Itoiz, María Elina; et al.; Biodistribution of GB-10 (Na2 10B10H10) compound for boron neutron capture therapy (BNCT) in an experimental model of oral cancer in the hamster cheek pouch; Elsevier; Archives of Oral Biology; 49; 4; 12-2004; 313-324 0003-9969 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/162651 |
identifier_str_mv |
Heber, Elisa Mercedes; Trivillin, Verónica Andrea; Nigg, David; Kreimann, Erica Lorena; Itoiz, María Elina; et al.; Biodistribution of GB-10 (Na2 10B10H10) compound for boron neutron capture therapy (BNCT) in an experimental model of oral cancer in the hamster cheek pouch; Elsevier; Archives of Oral Biology; 49; 4; 12-2004; 313-324 0003-9969 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0003996903002632 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.archoralbio.2003.10.003 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1842269361654464512 |
score |
13.13397 |