Exploiting the synergistic effect of concurrent data signals: Low-level fusion of liquid chromatographic with dual detection data
- Autores
- Teglia, Carla Mariela; Azcarate, Silvana Mariela; Alcaraz, Mirta Raquel; Goicoechea, Hector Casimiro; Culzoni, Maria Julia
- Año de publicación
- 2018
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- A low-level data fusion strategy was developed and implemented for data processing of second-order liquid chromatographic data with dual detection, i.e. absorbance and fluorescence monitoring. The synergistic effect of coupling individual information provided by two different detectors was evaluated by analyzing the results gathered after the application of a series of data preprocessing steps and chemometric resolution. The chemometric modeling involved data analysis by MCR-ALS, PARAFAC and N-PLS. Their ability to handle the new data block was assessed through the estimation of the analytical figures of merits achieved in the prediction of a validation set containing fifteen fluorescent and non-fluorescent veterinary active ingredients that can be found in poultry litter. Eventually, the feasibility of the application of the fusion strategy to real poultry litter samples containing the studied compounds was verified.
Fil: Teglia, Carla Mariela. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina
Fil: Azcarate, Silvana Mariela. Universidad Nacional de La Pampa; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Alcaraz, Mirta Raquel. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina
Fil: Goicoechea, Hector Casimiro. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina
Fil: Culzoni, Maria Julia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina - Materia
-
CHEMOMETRICS
DUAL DETECTION
LIQUID CHROMATOGRAPHY
LOW-LEVEL DATA FUSION
SECOND-ORDER DATA - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/83083
Ver los metadatos del registro completo
id |
CONICETDig_7815fe54ccd9707c8ca024ef24e90a3d |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/83083 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Exploiting the synergistic effect of concurrent data signals: Low-level fusion of liquid chromatographic with dual detection dataTeglia, Carla MarielaAzcarate, Silvana MarielaAlcaraz, Mirta RaquelGoicoechea, Hector CasimiroCulzoni, Maria JuliaCHEMOMETRICSDUAL DETECTIONLIQUID CHROMATOGRAPHYLOW-LEVEL DATA FUSIONSECOND-ORDER DATAhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1A low-level data fusion strategy was developed and implemented for data processing of second-order liquid chromatographic data with dual detection, i.e. absorbance and fluorescence monitoring. The synergistic effect of coupling individual information provided by two different detectors was evaluated by analyzing the results gathered after the application of a series of data preprocessing steps and chemometric resolution. The chemometric modeling involved data analysis by MCR-ALS, PARAFAC and N-PLS. Their ability to handle the new data block was assessed through the estimation of the analytical figures of merits achieved in the prediction of a validation set containing fifteen fluorescent and non-fluorescent veterinary active ingredients that can be found in poultry litter. Eventually, the feasibility of the application of the fusion strategy to real poultry litter samples containing the studied compounds was verified.Fil: Teglia, Carla Mariela. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; ArgentinaFil: Azcarate, Silvana Mariela. Universidad Nacional de La Pampa; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Alcaraz, Mirta Raquel. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; ArgentinaFil: Goicoechea, Hector Casimiro. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; ArgentinaFil: Culzoni, Maria Julia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; ArgentinaElsevier Science2018-08info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/83083Teglia, Carla Mariela; Azcarate, Silvana Mariela; Alcaraz, Mirta Raquel; Goicoechea, Hector Casimiro; Culzoni, Maria Julia; Exploiting the synergistic effect of concurrent data signals: Low-level fusion of liquid chromatographic with dual detection data; Elsevier Science; Talanta; 186; 8-2018; 481-4880039-9140CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.talanta.2018.04.090info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0039914018304478info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-10T13:07:51Zoai:ri.conicet.gov.ar:11336/83083instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-10 13:07:51.734CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Exploiting the synergistic effect of concurrent data signals: Low-level fusion of liquid chromatographic with dual detection data |
title |
Exploiting the synergistic effect of concurrent data signals: Low-level fusion of liquid chromatographic with dual detection data |
spellingShingle |
Exploiting the synergistic effect of concurrent data signals: Low-level fusion of liquid chromatographic with dual detection data Teglia, Carla Mariela CHEMOMETRICS DUAL DETECTION LIQUID CHROMATOGRAPHY LOW-LEVEL DATA FUSION SECOND-ORDER DATA |
title_short |
Exploiting the synergistic effect of concurrent data signals: Low-level fusion of liquid chromatographic with dual detection data |
title_full |
Exploiting the synergistic effect of concurrent data signals: Low-level fusion of liquid chromatographic with dual detection data |
title_fullStr |
Exploiting the synergistic effect of concurrent data signals: Low-level fusion of liquid chromatographic with dual detection data |
title_full_unstemmed |
Exploiting the synergistic effect of concurrent data signals: Low-level fusion of liquid chromatographic with dual detection data |
title_sort |
Exploiting the synergistic effect of concurrent data signals: Low-level fusion of liquid chromatographic with dual detection data |
dc.creator.none.fl_str_mv |
Teglia, Carla Mariela Azcarate, Silvana Mariela Alcaraz, Mirta Raquel Goicoechea, Hector Casimiro Culzoni, Maria Julia |
author |
Teglia, Carla Mariela |
author_facet |
Teglia, Carla Mariela Azcarate, Silvana Mariela Alcaraz, Mirta Raquel Goicoechea, Hector Casimiro Culzoni, Maria Julia |
author_role |
author |
author2 |
Azcarate, Silvana Mariela Alcaraz, Mirta Raquel Goicoechea, Hector Casimiro Culzoni, Maria Julia |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
CHEMOMETRICS DUAL DETECTION LIQUID CHROMATOGRAPHY LOW-LEVEL DATA FUSION SECOND-ORDER DATA |
topic |
CHEMOMETRICS DUAL DETECTION LIQUID CHROMATOGRAPHY LOW-LEVEL DATA FUSION SECOND-ORDER DATA |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
A low-level data fusion strategy was developed and implemented for data processing of second-order liquid chromatographic data with dual detection, i.e. absorbance and fluorescence monitoring. The synergistic effect of coupling individual information provided by two different detectors was evaluated by analyzing the results gathered after the application of a series of data preprocessing steps and chemometric resolution. The chemometric modeling involved data analysis by MCR-ALS, PARAFAC and N-PLS. Their ability to handle the new data block was assessed through the estimation of the analytical figures of merits achieved in the prediction of a validation set containing fifteen fluorescent and non-fluorescent veterinary active ingredients that can be found in poultry litter. Eventually, the feasibility of the application of the fusion strategy to real poultry litter samples containing the studied compounds was verified. Fil: Teglia, Carla Mariela. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina Fil: Azcarate, Silvana Mariela. Universidad Nacional de La Pampa; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Alcaraz, Mirta Raquel. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina Fil: Goicoechea, Hector Casimiro. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina Fil: Culzoni, Maria Julia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina. Universidad Nacional del Litoral. Facultad de Bioquímica y Ciencias Biológicas; Argentina |
description |
A low-level data fusion strategy was developed and implemented for data processing of second-order liquid chromatographic data with dual detection, i.e. absorbance and fluorescence monitoring. The synergistic effect of coupling individual information provided by two different detectors was evaluated by analyzing the results gathered after the application of a series of data preprocessing steps and chemometric resolution. The chemometric modeling involved data analysis by MCR-ALS, PARAFAC and N-PLS. Their ability to handle the new data block was assessed through the estimation of the analytical figures of merits achieved in the prediction of a validation set containing fifteen fluorescent and non-fluorescent veterinary active ingredients that can be found in poultry litter. Eventually, the feasibility of the application of the fusion strategy to real poultry litter samples containing the studied compounds was verified. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-08 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/83083 Teglia, Carla Mariela; Azcarate, Silvana Mariela; Alcaraz, Mirta Raquel; Goicoechea, Hector Casimiro; Culzoni, Maria Julia; Exploiting the synergistic effect of concurrent data signals: Low-level fusion of liquid chromatographic with dual detection data; Elsevier Science; Talanta; 186; 8-2018; 481-488 0039-9140 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/83083 |
identifier_str_mv |
Teglia, Carla Mariela; Azcarate, Silvana Mariela; Alcaraz, Mirta Raquel; Goicoechea, Hector Casimiro; Culzoni, Maria Julia; Exploiting the synergistic effect of concurrent data signals: Low-level fusion of liquid chromatographic with dual detection data; Elsevier Science; Talanta; 186; 8-2018; 481-488 0039-9140 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.talanta.2018.04.090 info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0039914018304478 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier Science |
publisher.none.fl_str_mv |
Elsevier Science |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1842980360516796416 |
score |
12.993085 |