Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer Arm

Autores
Menendez, Lumila Paula
Año de publicación
2017
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Intraobserver error (INTRA-OE) is the difference between repeated measurements of the same variable made by the same observer. The objective of this work was to evaluate INTRA-OE from 3D landmarks registered with a Microscribe, in different datasets: (A) the 3D coordinates, (B) linear measurements calculated from A, and (C) the six-first principal component axes. INTRA-OE was analyzed by digitizing 42 landmarks from 23 skulls in three events two weeks apart from each other. Systematic error was tested through repeated measures ANOVA (ANOVA-RM), while random error through intraclass correlation coefficient. Results showed that the largest differences between the three observations were found in the first dataset. Some anatomical points like nasion, ectoconchion, temporosphenoparietal, asterion, and temporomandibular presented the highest INTRA-OE. In the second dataset, local distances had higher INTRA-OE than global distances while the third dataset showed the lowest INTRA-OE.
Fil: Menendez, Lumila Paula. Eberhard Karls Universität Tübingen. Institute For Archaeological Sciences.; Alemania. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina
Materia
CRANIOFACIAL MORPHOMETRY
FORENSIC SCIENCE
GEOMETRIC MORPHOMETRICS
INTRACLASS CORRELATION COEFFICIENT
INTRAOBSERVER ERROR
REPEATED MEASURES ANOVA
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/210516

id CONICETDig_57513974c3cab719eb124374be88e8bc
oai_identifier_str oai:ri.conicet.gov.ar:11336/210516
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer ArmMenendez, Lumila PaulaCRANIOFACIAL MORPHOMETRYFORENSIC SCIENCEGEOMETRIC MORPHOMETRICSINTRACLASS CORRELATION COEFFICIENTINTRAOBSERVER ERRORREPEATED MEASURES ANOVAhttps://purl.org/becyt/ford/6.1https://purl.org/becyt/ford/6Intraobserver error (INTRA-OE) is the difference between repeated measurements of the same variable made by the same observer. The objective of this work was to evaluate INTRA-OE from 3D landmarks registered with a Microscribe, in different datasets: (A) the 3D coordinates, (B) linear measurements calculated from A, and (C) the six-first principal component axes. INTRA-OE was analyzed by digitizing 42 landmarks from 23 skulls in three events two weeks apart from each other. Systematic error was tested through repeated measures ANOVA (ANOVA-RM), while random error through intraclass correlation coefficient. Results showed that the largest differences between the three observations were found in the first dataset. Some anatomical points like nasion, ectoconchion, temporosphenoparietal, asterion, and temporomandibular presented the highest INTRA-OE. In the second dataset, local distances had higher INTRA-OE than global distances while the third dataset showed the lowest INTRA-OE.Fil: Menendez, Lumila Paula. Eberhard Karls Universität Tübingen. Institute For Archaeological Sciences.; Alemania. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; ArgentinaWiley Blackwell Publishing, Inc2017-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/210516Menendez, Lumila Paula; Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer Arm; Wiley Blackwell Publishing, Inc; Journal of Forensic Sciences; 62; 3; 3-2017; 741-7460022-1198CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1111/1556-4029.13301info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-11-05T09:43:40Zoai:ri.conicet.gov.ar:11336/210516instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-11-05 09:43:40.685CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer Arm
title Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer Arm
spellingShingle Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer Arm
Menendez, Lumila Paula
CRANIOFACIAL MORPHOMETRY
FORENSIC SCIENCE
GEOMETRIC MORPHOMETRICS
INTRACLASS CORRELATION COEFFICIENT
INTRAOBSERVER ERROR
REPEATED MEASURES ANOVA
title_short Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer Arm
title_full Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer Arm
title_fullStr Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer Arm
title_full_unstemmed Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer Arm
title_sort Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer Arm
dc.creator.none.fl_str_mv Menendez, Lumila Paula
author Menendez, Lumila Paula
author_facet Menendez, Lumila Paula
author_role author
dc.subject.none.fl_str_mv CRANIOFACIAL MORPHOMETRY
FORENSIC SCIENCE
GEOMETRIC MORPHOMETRICS
INTRACLASS CORRELATION COEFFICIENT
INTRAOBSERVER ERROR
REPEATED MEASURES ANOVA
topic CRANIOFACIAL MORPHOMETRY
FORENSIC SCIENCE
GEOMETRIC MORPHOMETRICS
INTRACLASS CORRELATION COEFFICIENT
INTRAOBSERVER ERROR
REPEATED MEASURES ANOVA
purl_subject.fl_str_mv https://purl.org/becyt/ford/6.1
https://purl.org/becyt/ford/6
dc.description.none.fl_txt_mv Intraobserver error (INTRA-OE) is the difference between repeated measurements of the same variable made by the same observer. The objective of this work was to evaluate INTRA-OE from 3D landmarks registered with a Microscribe, in different datasets: (A) the 3D coordinates, (B) linear measurements calculated from A, and (C) the six-first principal component axes. INTRA-OE was analyzed by digitizing 42 landmarks from 23 skulls in three events two weeks apart from each other. Systematic error was tested through repeated measures ANOVA (ANOVA-RM), while random error through intraclass correlation coefficient. Results showed that the largest differences between the three observations were found in the first dataset. Some anatomical points like nasion, ectoconchion, temporosphenoparietal, asterion, and temporomandibular presented the highest INTRA-OE. In the second dataset, local distances had higher INTRA-OE than global distances while the third dataset showed the lowest INTRA-OE.
Fil: Menendez, Lumila Paula. Eberhard Karls Universität Tübingen. Institute For Archaeological Sciences.; Alemania. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina
description Intraobserver error (INTRA-OE) is the difference between repeated measurements of the same variable made by the same observer. The objective of this work was to evaluate INTRA-OE from 3D landmarks registered with a Microscribe, in different datasets: (A) the 3D coordinates, (B) linear measurements calculated from A, and (C) the six-first principal component axes. INTRA-OE was analyzed by digitizing 42 landmarks from 23 skulls in three events two weeks apart from each other. Systematic error was tested through repeated measures ANOVA (ANOVA-RM), while random error through intraclass correlation coefficient. Results showed that the largest differences between the three observations were found in the first dataset. Some anatomical points like nasion, ectoconchion, temporosphenoparietal, asterion, and temporomandibular presented the highest INTRA-OE. In the second dataset, local distances had higher INTRA-OE than global distances while the third dataset showed the lowest INTRA-OE.
publishDate 2017
dc.date.none.fl_str_mv 2017-03
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/210516
Menendez, Lumila Paula; Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer Arm; Wiley Blackwell Publishing, Inc; Journal of Forensic Sciences; 62; 3; 3-2017; 741-746
0022-1198
CONICET Digital
CONICET
url http://hdl.handle.net/11336/210516
identifier_str_mv Menendez, Lumila Paula; Comparing Methods to Assess Intraobserver Measurement Error of 3D Craniofacial Landmarks Using Geometric Morphometrics Through a Digitizer Arm; Wiley Blackwell Publishing, Inc; Journal of Forensic Sciences; 62; 3; 3-2017; 741-746
0022-1198
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/10.1111/1556-4029.13301
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Wiley Blackwell Publishing, Inc
publisher.none.fl_str_mv Wiley Blackwell Publishing, Inc
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1847977031822737408
score 13.087074