Noninvasive quantitative imaging of selective microstructure sizes via magnetic resonance
- Autores
- Capiglioni, Milena Sofía; Zwick, Analía Elizabeth; Jiménez, Pablo Javier; Álvarez, Gonzalo A.
- Año de publicación
- 2021
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Extracting quantitative microstructure information of living tissue by noninvasive imaging is an outstanding challenge for understanding disease mechanisms and allowing early stage diagnosis of pathologies. Magnetic resonance imaging (MRI) is a promising and widely used technique to pursue this goal, but still provides low resolution to reveal microstructure details. We here report on a method to produce images of filtered microstructure sizes based on selectively probing the nuclear-spin dephasing induced by the molecular diffusion within specific tissue compartments. The microstructure-size filter relies on suitable dynamical control of nuclear spins that sense magnetization "decay shifts"rather than the commonly used spin-echo decay rates. The feasibility and performance of the method are illustrated with proof-of-principle experiments and simulations on typical size distributions of white matter in the mouse brain. These results position spin-echo decay shifts as a promising MRI tool as they could offer the ability to perform noninvasive histology without assuming a microstructure distribution model. This sets a step towards unraveling diagnostic information based on microscopic parameters of biological tissue.
Fil: Capiglioni, Milena Sofía. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. University of Bern; Suiza. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Zwick, Analía Elizabeth. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología - Nodo Bariloche | Comisión Nacional de Energía Atómica. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología - Nodo Bariloche; Argentina
Fil: Jiménez, Pablo Javier. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Álvarez, Gonzalo A.. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología - Nodo Bariloche | Comisión Nacional de Energía Atómica. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología - Nodo Bariloche; Argentina - Materia
-
MRI
NMR
Difussion Molecular
Tissue Microstructure - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/148130
Ver los metadatos del registro completo
id |
CONICETDig_2795087decc4f1c40595d8618351ddf8 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/148130 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Noninvasive quantitative imaging of selective microstructure sizes via magnetic resonanceCapiglioni, Milena SofíaZwick, Analía ElizabethJiménez, Pablo JavierÁlvarez, Gonzalo A.MRINMRDifussion MolecularTissue Microstructurehttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1Extracting quantitative microstructure information of living tissue by noninvasive imaging is an outstanding challenge for understanding disease mechanisms and allowing early stage diagnosis of pathologies. Magnetic resonance imaging (MRI) is a promising and widely used technique to pursue this goal, but still provides low resolution to reveal microstructure details. We here report on a method to produce images of filtered microstructure sizes based on selectively probing the nuclear-spin dephasing induced by the molecular diffusion within specific tissue compartments. The microstructure-size filter relies on suitable dynamical control of nuclear spins that sense magnetization "decay shifts"rather than the commonly used spin-echo decay rates. The feasibility and performance of the method are illustrated with proof-of-principle experiments and simulations on typical size distributions of white matter in the mouse brain. These results position spin-echo decay shifts as a promising MRI tool as they could offer the ability to perform noninvasive histology without assuming a microstructure distribution model. This sets a step towards unraveling diagnostic information based on microscopic parameters of biological tissue.Fil: Capiglioni, Milena Sofía. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. University of Bern; Suiza. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Zwick, Analía Elizabeth. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología - Nodo Bariloche | Comisión Nacional de Energía Atómica. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología - Nodo Bariloche; ArgentinaFil: Jiménez, Pablo Javier. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Álvarez, Gonzalo A.. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología - Nodo Bariloche | Comisión Nacional de Energía Atómica. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología - Nodo Bariloche; ArgentinaAmerican Physical Society2021-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/148130Capiglioni, Milena Sofía; Zwick, Analía Elizabeth; Jiménez, Pablo Javier; Álvarez, Gonzalo A.; Noninvasive quantitative imaging of selective microstructure sizes via magnetic resonance; American Physical Society; Physical Review Applied; 15; 1; 1-2021; 1-112331-7019CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://journals.aps.org/prapplied/abstract/10.1103/PhysRevApplied.15.014045info:eu-repo/semantics/altIdentifier/doi/10.1103/PhysRevApplied.15.014045info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-10T13:09:58Zoai:ri.conicet.gov.ar:11336/148130instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-10 13:09:58.855CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Noninvasive quantitative imaging of selective microstructure sizes via magnetic resonance |
title |
Noninvasive quantitative imaging of selective microstructure sizes via magnetic resonance |
spellingShingle |
Noninvasive quantitative imaging of selective microstructure sizes via magnetic resonance Capiglioni, Milena Sofía MRI NMR Difussion Molecular Tissue Microstructure |
title_short |
Noninvasive quantitative imaging of selective microstructure sizes via magnetic resonance |
title_full |
Noninvasive quantitative imaging of selective microstructure sizes via magnetic resonance |
title_fullStr |
Noninvasive quantitative imaging of selective microstructure sizes via magnetic resonance |
title_full_unstemmed |
Noninvasive quantitative imaging of selective microstructure sizes via magnetic resonance |
title_sort |
Noninvasive quantitative imaging of selective microstructure sizes via magnetic resonance |
dc.creator.none.fl_str_mv |
Capiglioni, Milena Sofía Zwick, Analía Elizabeth Jiménez, Pablo Javier Álvarez, Gonzalo A. |
author |
Capiglioni, Milena Sofía |
author_facet |
Capiglioni, Milena Sofía Zwick, Analía Elizabeth Jiménez, Pablo Javier Álvarez, Gonzalo A. |
author_role |
author |
author2 |
Zwick, Analía Elizabeth Jiménez, Pablo Javier Álvarez, Gonzalo A. |
author2_role |
author author author |
dc.subject.none.fl_str_mv |
MRI NMR Difussion Molecular Tissue Microstructure |
topic |
MRI NMR Difussion Molecular Tissue Microstructure |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.3 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
Extracting quantitative microstructure information of living tissue by noninvasive imaging is an outstanding challenge for understanding disease mechanisms and allowing early stage diagnosis of pathologies. Magnetic resonance imaging (MRI) is a promising and widely used technique to pursue this goal, but still provides low resolution to reveal microstructure details. We here report on a method to produce images of filtered microstructure sizes based on selectively probing the nuclear-spin dephasing induced by the molecular diffusion within specific tissue compartments. The microstructure-size filter relies on suitable dynamical control of nuclear spins that sense magnetization "decay shifts"rather than the commonly used spin-echo decay rates. The feasibility and performance of the method are illustrated with proof-of-principle experiments and simulations on typical size distributions of white matter in the mouse brain. These results position spin-echo decay shifts as a promising MRI tool as they could offer the ability to perform noninvasive histology without assuming a microstructure distribution model. This sets a step towards unraveling diagnostic information based on microscopic parameters of biological tissue. Fil: Capiglioni, Milena Sofía. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. University of Bern; Suiza. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Zwick, Analía Elizabeth. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología - Nodo Bariloche | Comisión Nacional de Energía Atómica. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología - Nodo Bariloche; Argentina Fil: Jiménez, Pablo Javier. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina Fil: Álvarez, Gonzalo A.. Comisión Nacional de Energía Atómica. Centro Atómico Bariloche; Argentina. Comisión Nacional de Energía Atómica. Gerencia del Área de Energía Nuclear. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro | Universidad Nacional de Cuyo. Instituto Balseiro. Archivo Histórico del Centro Atómico Bariloche e Instituto Balseiro; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología - Nodo Bariloche | Comisión Nacional de Energía Atómica. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología. Unidad Ejecutora Instituto de Nanociencia y Nanotecnología - Nodo Bariloche; Argentina |
description |
Extracting quantitative microstructure information of living tissue by noninvasive imaging is an outstanding challenge for understanding disease mechanisms and allowing early stage diagnosis of pathologies. Magnetic resonance imaging (MRI) is a promising and widely used technique to pursue this goal, but still provides low resolution to reveal microstructure details. We here report on a method to produce images of filtered microstructure sizes based on selectively probing the nuclear-spin dephasing induced by the molecular diffusion within specific tissue compartments. The microstructure-size filter relies on suitable dynamical control of nuclear spins that sense magnetization "decay shifts"rather than the commonly used spin-echo decay rates. The feasibility and performance of the method are illustrated with proof-of-principle experiments and simulations on typical size distributions of white matter in the mouse brain. These results position spin-echo decay shifts as a promising MRI tool as they could offer the ability to perform noninvasive histology without assuming a microstructure distribution model. This sets a step towards unraveling diagnostic information based on microscopic parameters of biological tissue. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/148130 Capiglioni, Milena Sofía; Zwick, Analía Elizabeth; Jiménez, Pablo Javier; Álvarez, Gonzalo A.; Noninvasive quantitative imaging of selective microstructure sizes via magnetic resonance; American Physical Society; Physical Review Applied; 15; 1; 1-2021; 1-11 2331-7019 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/148130 |
identifier_str_mv |
Capiglioni, Milena Sofía; Zwick, Analía Elizabeth; Jiménez, Pablo Javier; Álvarez, Gonzalo A.; Noninvasive quantitative imaging of selective microstructure sizes via magnetic resonance; American Physical Society; Physical Review Applied; 15; 1; 1-2021; 1-11 2331-7019 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://journals.aps.org/prapplied/abstract/10.1103/PhysRevApplied.15.014045 info:eu-repo/semantics/altIdentifier/doi/10.1103/PhysRevApplied.15.014045 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
American Physical Society |
publisher.none.fl_str_mv |
American Physical Society |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1842980496812802048 |
score |
12.993085 |