Modified paramagnetic beads in a microfluidic system for the determination of zearalenone in feedstuffs samples
- Autores
- Panini, Nancy Veronica; Salinas, Eloy; Messina, Germán Alejandro; Raba, Julio
- Año de publicación
- 2011
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- In this work, we have developed and characterised a novel microfluidic immunoassay methodology for rapid and sensitive quantification of ZEA in feedstuffs samples. The detection of ZEA was carried out using a competitive direct immunoassay method based on the use of anti-ZEA monoclonal antibodies immobilized on magnetic microspheres 3-aminopropyl-modified manipulated for an external remobilize magnets. The ZEA in feedstuffs sample is allowed to compete with ZEA-horseradish peroxidase (HPR) conjugated for the immobilized anti-ZEA antibody. The HPR, in the presence of hydrogen peroxide (H2O2) catalyses the oxidation of 4-tert-butylcatechol (4-TBC) whose back electrochemical reduction was detected on gold electrode at 0.0V. The calculated detection limits for electrochemical detection and ELISA procedure were 0.41 and 2.56μgkg-1 respectively, the intra and inter-assay coefficients of variation were below 6.5% and the total assay time was 30min. The microfluidic immunosensor showed higher sensitivity and lower detection limits than the standard ELISA method, which shows potential for detecting ZEA in foods and feeds diagnosis.
Fil: Panini, Nancy Veronica. Universidad Nacional de San Luis; Argentina
Fil: Salinas Eloy. Universidad Nacional de San Luis; Argentina
Fil: Messina, Germán Alejandro. Instituto de Química de San Luis, Universidad Nacional de San luis, Fcaultad de Quimica, Bioquimica y Farmacia.; Argentina
Fil: Raba, Julio. Instituto de Química de San Luis, Universidad Nacional de San luis, Fcaultad de Quimica, Bioquimica y Farmacia.; Argentina; Argentina - Materia
-
ENZYME IMMUNOASSAYS
FLOW INJECTION ANALYSIS
HORSERADISH PEROXIDASE
MICROFLUIDIC
PARAMAGNETIC BEADS
ZEARALENONE - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
.jpg)
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/92856
Ver los metadatos del registro completo
| id |
CONICETDig_264af7e695893c4c5ddc4a0271a8d5ae |
|---|---|
| oai_identifier_str |
oai:ri.conicet.gov.ar:11336/92856 |
| network_acronym_str |
CONICETDig |
| repository_id_str |
3498 |
| network_name_str |
CONICET Digital (CONICET) |
| spelling |
Modified paramagnetic beads in a microfluidic system for the determination of zearalenone in feedstuffs samplesPanini, Nancy VeronicaSalinas, EloyMessina, Germán AlejandroRaba, JulioENZYME IMMUNOASSAYSFLOW INJECTION ANALYSISHORSERADISH PEROXIDASEMICROFLUIDICPARAMAGNETIC BEADSZEARALENONEhttps://purl.org/becyt/ford/4.2https://purl.org/becyt/ford/4In this work, we have developed and characterised a novel microfluidic immunoassay methodology for rapid and sensitive quantification of ZEA in feedstuffs samples. The detection of ZEA was carried out using a competitive direct immunoassay method based on the use of anti-ZEA monoclonal antibodies immobilized on magnetic microspheres 3-aminopropyl-modified manipulated for an external remobilize magnets. The ZEA in feedstuffs sample is allowed to compete with ZEA-horseradish peroxidase (HPR) conjugated for the immobilized anti-ZEA antibody. The HPR, in the presence of hydrogen peroxide (H2O2) catalyses the oxidation of 4-tert-butylcatechol (4-TBC) whose back electrochemical reduction was detected on gold electrode at 0.0V. The calculated detection limits for electrochemical detection and ELISA procedure were 0.41 and 2.56μgkg-1 respectively, the intra and inter-assay coefficients of variation were below 6.5% and the total assay time was 30min. The microfluidic immunosensor showed higher sensitivity and lower detection limits than the standard ELISA method, which shows potential for detecting ZEA in foods and feeds diagnosis.Fil: Panini, Nancy Veronica. Universidad Nacional de San Luis; ArgentinaFil: Salinas Eloy. Universidad Nacional de San Luis; ArgentinaFil: Messina, Germán Alejandro. Instituto de Química de San Luis, Universidad Nacional de San luis, Fcaultad de Quimica, Bioquimica y Farmacia.; ArgentinaFil: Raba, Julio. Instituto de Química de San Luis, Universidad Nacional de San luis, Fcaultad de Quimica, Bioquimica y Farmacia.; Argentina; ArgentinaElsevier2011-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/92856Panini, Nancy Veronica; Salinas, Eloy; Messina, Germán Alejandro; Raba, Julio; Modified paramagnetic beads in a microfluidic system for the determination of zearalenone in feedstuffs samples; Elsevier; Food Chemistry; 125; 2; 3-2011; 791-7960308-8146CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.foodchem.2010.09.035info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0308814610011088info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-22T11:58:33Zoai:ri.conicet.gov.ar:11336/92856instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-22 11:58:33.46CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
| dc.title.none.fl_str_mv |
Modified paramagnetic beads in a microfluidic system for the determination of zearalenone in feedstuffs samples |
| title |
Modified paramagnetic beads in a microfluidic system for the determination of zearalenone in feedstuffs samples |
| spellingShingle |
Modified paramagnetic beads in a microfluidic system for the determination of zearalenone in feedstuffs samples Panini, Nancy Veronica ENZYME IMMUNOASSAYS FLOW INJECTION ANALYSIS HORSERADISH PEROXIDASE MICROFLUIDIC PARAMAGNETIC BEADS ZEARALENONE |
| title_short |
Modified paramagnetic beads in a microfluidic system for the determination of zearalenone in feedstuffs samples |
| title_full |
Modified paramagnetic beads in a microfluidic system for the determination of zearalenone in feedstuffs samples |
| title_fullStr |
Modified paramagnetic beads in a microfluidic system for the determination of zearalenone in feedstuffs samples |
| title_full_unstemmed |
Modified paramagnetic beads in a microfluidic system for the determination of zearalenone in feedstuffs samples |
| title_sort |
Modified paramagnetic beads in a microfluidic system for the determination of zearalenone in feedstuffs samples |
| dc.creator.none.fl_str_mv |
Panini, Nancy Veronica Salinas, Eloy Messina, Germán Alejandro Raba, Julio |
| author |
Panini, Nancy Veronica |
| author_facet |
Panini, Nancy Veronica Salinas, Eloy Messina, Germán Alejandro Raba, Julio |
| author_role |
author |
| author2 |
Salinas, Eloy Messina, Germán Alejandro Raba, Julio |
| author2_role |
author author author |
| dc.subject.none.fl_str_mv |
ENZYME IMMUNOASSAYS FLOW INJECTION ANALYSIS HORSERADISH PEROXIDASE MICROFLUIDIC PARAMAGNETIC BEADS ZEARALENONE |
| topic |
ENZYME IMMUNOASSAYS FLOW INJECTION ANALYSIS HORSERADISH PEROXIDASE MICROFLUIDIC PARAMAGNETIC BEADS ZEARALENONE |
| purl_subject.fl_str_mv |
https://purl.org/becyt/ford/4.2 https://purl.org/becyt/ford/4 |
| dc.description.none.fl_txt_mv |
In this work, we have developed and characterised a novel microfluidic immunoassay methodology for rapid and sensitive quantification of ZEA in feedstuffs samples. The detection of ZEA was carried out using a competitive direct immunoassay method based on the use of anti-ZEA monoclonal antibodies immobilized on magnetic microspheres 3-aminopropyl-modified manipulated for an external remobilize magnets. The ZEA in feedstuffs sample is allowed to compete with ZEA-horseradish peroxidase (HPR) conjugated for the immobilized anti-ZEA antibody. The HPR, in the presence of hydrogen peroxide (H2O2) catalyses the oxidation of 4-tert-butylcatechol (4-TBC) whose back electrochemical reduction was detected on gold electrode at 0.0V. The calculated detection limits for electrochemical detection and ELISA procedure were 0.41 and 2.56μgkg-1 respectively, the intra and inter-assay coefficients of variation were below 6.5% and the total assay time was 30min. The microfluidic immunosensor showed higher sensitivity and lower detection limits than the standard ELISA method, which shows potential for detecting ZEA in foods and feeds diagnosis. Fil: Panini, Nancy Veronica. Universidad Nacional de San Luis; Argentina Fil: Salinas Eloy. Universidad Nacional de San Luis; Argentina Fil: Messina, Germán Alejandro. Instituto de Química de San Luis, Universidad Nacional de San luis, Fcaultad de Quimica, Bioquimica y Farmacia.; Argentina Fil: Raba, Julio. Instituto de Química de San Luis, Universidad Nacional de San luis, Fcaultad de Quimica, Bioquimica y Farmacia.; Argentina; Argentina |
| description |
In this work, we have developed and characterised a novel microfluidic immunoassay methodology for rapid and sensitive quantification of ZEA in feedstuffs samples. The detection of ZEA was carried out using a competitive direct immunoassay method based on the use of anti-ZEA monoclonal antibodies immobilized on magnetic microspheres 3-aminopropyl-modified manipulated for an external remobilize magnets. The ZEA in feedstuffs sample is allowed to compete with ZEA-horseradish peroxidase (HPR) conjugated for the immobilized anti-ZEA antibody. The HPR, in the presence of hydrogen peroxide (H2O2) catalyses the oxidation of 4-tert-butylcatechol (4-TBC) whose back electrochemical reduction was detected on gold electrode at 0.0V. The calculated detection limits for electrochemical detection and ELISA procedure were 0.41 and 2.56μgkg-1 respectively, the intra and inter-assay coefficients of variation were below 6.5% and the total assay time was 30min. The microfluidic immunosensor showed higher sensitivity and lower detection limits than the standard ELISA method, which shows potential for detecting ZEA in foods and feeds diagnosis. |
| publishDate |
2011 |
| dc.date.none.fl_str_mv |
2011-03 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/92856 Panini, Nancy Veronica; Salinas, Eloy; Messina, Germán Alejandro; Raba, Julio; Modified paramagnetic beads in a microfluidic system for the determination of zearalenone in feedstuffs samples; Elsevier; Food Chemistry; 125; 2; 3-2011; 791-796 0308-8146 CONICET Digital CONICET |
| url |
http://hdl.handle.net/11336/92856 |
| identifier_str_mv |
Panini, Nancy Veronica; Salinas, Eloy; Messina, Germán Alejandro; Raba, Julio; Modified paramagnetic beads in a microfluidic system for the determination of zearalenone in feedstuffs samples; Elsevier; Food Chemistry; 125; 2; 3-2011; 791-796 0308-8146 CONICET Digital CONICET |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.foodchem.2010.09.035 info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0308814610011088 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| dc.format.none.fl_str_mv |
application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier |
| publisher.none.fl_str_mv |
Elsevier |
| dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
| reponame_str |
CONICET Digital (CONICET) |
| collection |
CONICET Digital (CONICET) |
| instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
| _version_ |
1846782300900032512 |
| score |
12.982451 |