Emergency gate closing in a Kaplan turbine intake for runaway condition: CFD transient study for two-phase flow and experimental validation

Autores
Rivetti, Arturo; Angarita, G; Angulo, Mauricio Abel; Botero, Francisco; Liscia, Sergio Oscar
Año de publicación
2021
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
In order to prevent a turbine to reach its runaway speed when load rejection occurs, an emergency closing system must be devised in case the regulation system fails. For Kaplan turbines, fixed wheel gates located in the turbine intake or in the draft tube outlet are usually employed. Gates of this type are move by gravity and the closing velocity is controlled by gantry cranes. The closing maneuver is complex due to the high flow rates inherent to runaway conditions and the rotational deceleration during the gate's closing time. Research on this topic is scarce and limited, and numerical studies are usually clouded by uncertainties concerning the setting of proper boundary conditions. In this work, the closing maneuver of the emergency fixed wheel gates at the intake of a Kaplan turbine was studied with CFD two-phase transient simulation. The software used was ANSYS CFX, that solves unsteady Navier-Stokes equations (URANS) by means of the finite volume method. The simulated domain includes a 2D case from one of the span of the semi-spiral casing and a 3D case of a complete span. Two types of simulation were considered, namely: quasi-steady state, where the position of the gate is fixed; and full transient state, where the gate movement was modelled by an immersed solid model. In search of the optimum model layout with its set of boundary conditions, numerical results were compared and validated against experiments performed on a physical scale model in accordance with IEC 60193 norms for several turbulence models. Results show that the pull-up force on the gate increases as it is being closed. Analysis of pressure fluctuation at different points of the gate suggest that the main frequency component is the vortex shedding of the gate lip.
Facultad de Ingeniería
Materia
Ingeniería
Kaplan turbine
Emergency closing system
Nivel de accesibilidad
acceso abierto
Condiciones de uso
http://creativecommons.org/licenses/by/3.0/
Repositorio
SEDICI (UNLP)
Institución
Universidad Nacional de La Plata
OAI Identificador
oai:sedici.unlp.edu.ar:10915/127962

id SEDICI_e4ad735bb1a496f3edfc3277c82296b7
oai_identifier_str oai:sedici.unlp.edu.ar:10915/127962
network_acronym_str SEDICI
repository_id_str 1329
network_name_str SEDICI (UNLP)
spelling Emergency gate closing in a Kaplan turbine intake for runaway condition: CFD transient study for two-phase flow and experimental validationRivetti, ArturoAngarita, GAngulo, Mauricio AbelBotero, FranciscoLiscia, Sergio OscarIngenieríaKaplan turbineEmergency closing systemIn order to prevent a turbine to reach its runaway speed when load rejection occurs, an emergency closing system must be devised in case the regulation system fails. For Kaplan turbines, fixed wheel gates located in the turbine intake or in the draft tube outlet are usually employed. Gates of this type are move by gravity and the closing velocity is controlled by gantry cranes. The closing maneuver is complex due to the high flow rates inherent to runaway conditions and the rotational deceleration during the gate's closing time. Research on this topic is scarce and limited, and numerical studies are usually clouded by uncertainties concerning the setting of proper boundary conditions. In this work, the closing maneuver of the emergency fixed wheel gates at the intake of a Kaplan turbine was studied with CFD two-phase transient simulation. The software used was ANSYS CFX, that solves unsteady Navier-Stokes equations (URANS) by means of the finite volume method. The simulated domain includes a 2D case from one of the span of the semi-spiral casing and a 3D case of a complete span. Two types of simulation were considered, namely: quasi-steady state, where the position of the gate is fixed; and full transient state, where the gate movement was modelled by an immersed solid model. In search of the optimum model layout with its set of boundary conditions, numerical results were compared and validated against experiments performed on a physical scale model in accordance with IEC 60193 norms for several turbulence models. Results show that the pull-up force on the gate increases as it is being closed. Analysis of pressure fluctuation at different points of the gate suggest that the main frequency component is the vortex shedding of the gate lip.Facultad de Ingeniería2021-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArticulohttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfhttp://sedici.unlp.edu.ar/handle/10915/127962enginfo:eu-repo/semantics/altIdentifier/issn/1755-1307info:eu-repo/semantics/altIdentifier/issn/1755-1315info:eu-repo/semantics/altIdentifier/doi/10.1088/1755-1315/774/1/012015info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by/3.0/Creative Commons Attribution 3.0 Unported (CC BY 3.0)reponame:SEDICI (UNLP)instname:Universidad Nacional de La Platainstacron:UNLP2025-09-03T11:03:04Zoai:sedici.unlp.edu.ar:10915/127962Institucionalhttp://sedici.unlp.edu.ar/Universidad públicaNo correspondehttp://sedici.unlp.edu.ar/oai/snrdalira@sedici.unlp.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:13292025-09-03 11:03:04.601SEDICI (UNLP) - Universidad Nacional de La Platafalse
dc.title.none.fl_str_mv Emergency gate closing in a Kaplan turbine intake for runaway condition: CFD transient study for two-phase flow and experimental validation
title Emergency gate closing in a Kaplan turbine intake for runaway condition: CFD transient study for two-phase flow and experimental validation
spellingShingle Emergency gate closing in a Kaplan turbine intake for runaway condition: CFD transient study for two-phase flow and experimental validation
Rivetti, Arturo
Ingeniería
Kaplan turbine
Emergency closing system
title_short Emergency gate closing in a Kaplan turbine intake for runaway condition: CFD transient study for two-phase flow and experimental validation
title_full Emergency gate closing in a Kaplan turbine intake for runaway condition: CFD transient study for two-phase flow and experimental validation
title_fullStr Emergency gate closing in a Kaplan turbine intake for runaway condition: CFD transient study for two-phase flow and experimental validation
title_full_unstemmed Emergency gate closing in a Kaplan turbine intake for runaway condition: CFD transient study for two-phase flow and experimental validation
title_sort Emergency gate closing in a Kaplan turbine intake for runaway condition: CFD transient study for two-phase flow and experimental validation
dc.creator.none.fl_str_mv Rivetti, Arturo
Angarita, G
Angulo, Mauricio Abel
Botero, Francisco
Liscia, Sergio Oscar
author Rivetti, Arturo
author_facet Rivetti, Arturo
Angarita, G
Angulo, Mauricio Abel
Botero, Francisco
Liscia, Sergio Oscar
author_role author
author2 Angarita, G
Angulo, Mauricio Abel
Botero, Francisco
Liscia, Sergio Oscar
author2_role author
author
author
author
dc.subject.none.fl_str_mv Ingeniería
Kaplan turbine
Emergency closing system
topic Ingeniería
Kaplan turbine
Emergency closing system
dc.description.none.fl_txt_mv In order to prevent a turbine to reach its runaway speed when load rejection occurs, an emergency closing system must be devised in case the regulation system fails. For Kaplan turbines, fixed wheel gates located in the turbine intake or in the draft tube outlet are usually employed. Gates of this type are move by gravity and the closing velocity is controlled by gantry cranes. The closing maneuver is complex due to the high flow rates inherent to runaway conditions and the rotational deceleration during the gate's closing time. Research on this topic is scarce and limited, and numerical studies are usually clouded by uncertainties concerning the setting of proper boundary conditions. In this work, the closing maneuver of the emergency fixed wheel gates at the intake of a Kaplan turbine was studied with CFD two-phase transient simulation. The software used was ANSYS CFX, that solves unsteady Navier-Stokes equations (URANS) by means of the finite volume method. The simulated domain includes a 2D case from one of the span of the semi-spiral casing and a 3D case of a complete span. Two types of simulation were considered, namely: quasi-steady state, where the position of the gate is fixed; and full transient state, where the gate movement was modelled by an immersed solid model. In search of the optimum model layout with its set of boundary conditions, numerical results were compared and validated against experiments performed on a physical scale model in accordance with IEC 60193 norms for several turbulence models. Results show that the pull-up force on the gate increases as it is being closed. Analysis of pressure fluctuation at different points of the gate suggest that the main frequency component is the vortex shedding of the gate lip.
Facultad de Ingeniería
description In order to prevent a turbine to reach its runaway speed when load rejection occurs, an emergency closing system must be devised in case the regulation system fails. For Kaplan turbines, fixed wheel gates located in the turbine intake or in the draft tube outlet are usually employed. Gates of this type are move by gravity and the closing velocity is controlled by gantry cranes. The closing maneuver is complex due to the high flow rates inherent to runaway conditions and the rotational deceleration during the gate's closing time. Research on this topic is scarce and limited, and numerical studies are usually clouded by uncertainties concerning the setting of proper boundary conditions. In this work, the closing maneuver of the emergency fixed wheel gates at the intake of a Kaplan turbine was studied with CFD two-phase transient simulation. The software used was ANSYS CFX, that solves unsteady Navier-Stokes equations (URANS) by means of the finite volume method. The simulated domain includes a 2D case from one of the span of the semi-spiral casing and a 3D case of a complete span. Two types of simulation were considered, namely: quasi-steady state, where the position of the gate is fixed; and full transient state, where the gate movement was modelled by an immersed solid model. In search of the optimum model layout with its set of boundary conditions, numerical results were compared and validated against experiments performed on a physical scale model in accordance with IEC 60193 norms for several turbulence models. Results show that the pull-up force on the gate increases as it is being closed. Analysis of pressure fluctuation at different points of the gate suggest that the main frequency component is the vortex shedding of the gate lip.
publishDate 2021
dc.date.none.fl_str_mv 2021-06-01
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Articulo
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://sedici.unlp.edu.ar/handle/10915/127962
url http://sedici.unlp.edu.ar/handle/10915/127962
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/issn/1755-1307
info:eu-repo/semantics/altIdentifier/issn/1755-1315
info:eu-repo/semantics/altIdentifier/doi/10.1088/1755-1315/774/1/012015
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
http://creativecommons.org/licenses/by/3.0/
Creative Commons Attribution 3.0 Unported (CC BY 3.0)
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by/3.0/
Creative Commons Attribution 3.0 Unported (CC BY 3.0)
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:SEDICI (UNLP)
instname:Universidad Nacional de La Plata
instacron:UNLP
reponame_str SEDICI (UNLP)
collection SEDICI (UNLP)
instname_str Universidad Nacional de La Plata
instacron_str UNLP
institution UNLP
repository.name.fl_str_mv SEDICI (UNLP) - Universidad Nacional de La Plata
repository.mail.fl_str_mv alira@sedici.unlp.edu.ar
_version_ 1842260529349918720
score 13.13397