Descripción
The non stopping growth of urban centers and increasing demand for electrical energy causes more high voltage lines and underground cables installed in cities. As a direct consequence, the generation of Magnetic Fields (MF) is increased due to the new power lines and cables. Magnetic Fields have raised concerns in the population for years by its association with possible health effects. Before building new facilities it is necessary to assess whether these would meet the requirements of the regulations. Thus it is necessary to have tools that quantify the MF values emitted by the planned facilities. In the laying of cables, two zones are identified. The first one is where the phases are regularly laid close to each other. The other area is where the joints are made. In this area is where the distances between phases are higher. In the latter, the magnetic field values are higher due to the increase of the separation.
Trabajo C3-203. 46ª CIGRÉ SESSION (International Council on Large Electric Systems).
Instituto de Investigaciones Tecnológicas para Redes y Equipos Eléctricos
Materia
Ingeniería
Energía Eléctrica
Nivel de accesibilidad
acceso abierto
Condiciones de uso
http://creativecommons.org/licenses/by-nc-nd/4.0/
Repositorio
SEDICI (UNLP)
Institución
Universidad Nacional de La Plata
OAI Identificador
oai:sedici.unlp.edu.ar:10915/67665

id SEDICI_6f194748f73ea03f2198892a20117b7e
oai_identifier_str oai:sedici.unlp.edu.ar:10915/67665
network_acronym_str SEDICI
repository_id_str 1329
network_name_str SEDICI (UNLP)
spelling HV Underground Cables Magnetic Field Mitigation MeasuresWall, Carlos AlbertoArnera, Patricia LilianaBarbieri, María BeatrizIngenieríaEnergía EléctricaThe non stopping growth of urban centers and increasing demand for electrical energy causes more high voltage lines and underground cables installed in cities. As a direct consequence, the generation of Magnetic Fields (MF) is increased due to the new power lines and cables. Magnetic Fields have raised concerns in the population for years by its association with possible health effects. Before building new facilities it is necessary to assess whether these would meet the requirements of the regulations. Thus it is necessary to have tools that quantify the MF values emitted by the planned facilities. In the laying of cables, two zones are identified. The first one is where the phases are regularly laid close to each other. The other area is where the joints are made. In this area is where the distances between phases are higher. In the latter, the magnetic field values are higher due to the increase of the separation.Trabajo C3-203. 46ª CIGRÉ SESSION (International Council on Large Electric Systems).Instituto de Investigaciones Tecnológicas para Redes y Equipos Eléctricos2016-08info:eu-repo/semantics/conferenceObjectinfo:eu-repo/semantics/publishedVersionResumenhttp://purl.org/coar/resource_type/c_5794info:ar-repo/semantics/documentoDeConferenciaapplication/pdfhttp://sedici.unlp.edu.ar/handle/10915/67665spainfo:eu-repo/semantics/altIdentifier/url/https://app.box.com/s/7qryg6t4qxpysi66maandups78dbegrlinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/4.0/Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)reponame:SEDICI (UNLP)instname:Universidad Nacional de La Platainstacron:UNLP2025-10-15T11:02:22Zoai:sedici.unlp.edu.ar:10915/67665Institucionalhttp://sedici.unlp.edu.ar/Universidad públicaNo correspondehttp://sedici.unlp.edu.ar/oai/snrdalira@sedici.unlp.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:13292025-10-15 11:02:22.805SEDICI (UNLP) - Universidad Nacional de La Platafalse
dc.title.none.fl_str_mv HV Underground Cables Magnetic Field Mitigation Measures
title HV Underground Cables Magnetic Field Mitigation Measures
spellingShingle HV Underground Cables Magnetic Field Mitigation Measures
Wall, Carlos Alberto
Ingeniería
Energía Eléctrica
title_short HV Underground Cables Magnetic Field Mitigation Measures
title_full HV Underground Cables Magnetic Field Mitigation Measures
title_fullStr HV Underground Cables Magnetic Field Mitigation Measures
title_full_unstemmed HV Underground Cables Magnetic Field Mitigation Measures
title_sort HV Underground Cables Magnetic Field Mitigation Measures
dc.creator.none.fl_str_mv Wall, Carlos Alberto
Arnera, Patricia Liliana
Barbieri, María Beatriz
author Wall, Carlos Alberto
author_facet Wall, Carlos Alberto
Arnera, Patricia Liliana
Barbieri, María Beatriz
author_role author
author2 Arnera, Patricia Liliana
Barbieri, María Beatriz
author2_role author
author
dc.subject.none.fl_str_mv Ingeniería
Energía Eléctrica
topic Ingeniería
Energía Eléctrica
dc.description.none.fl_txt_mv The non stopping growth of urban centers and increasing demand for electrical energy causes more high voltage lines and underground cables installed in cities. As a direct consequence, the generation of Magnetic Fields (MF) is increased due to the new power lines and cables. Magnetic Fields have raised concerns in the population for years by its association with possible health effects. Before building new facilities it is necessary to assess whether these would meet the requirements of the regulations. Thus it is necessary to have tools that quantify the MF values emitted by the planned facilities. In the laying of cables, two zones are identified. The first one is where the phases are regularly laid close to each other. The other area is where the joints are made. In this area is where the distances between phases are higher. In the latter, the magnetic field values are higher due to the increase of the separation.
Trabajo C3-203. 46ª CIGRÉ SESSION (International Council on Large Electric Systems).
Instituto de Investigaciones Tecnológicas para Redes y Equipos Eléctricos
description The non stopping growth of urban centers and increasing demand for electrical energy causes more high voltage lines and underground cables installed in cities. As a direct consequence, the generation of Magnetic Fields (MF) is increased due to the new power lines and cables. Magnetic Fields have raised concerns in the population for years by its association with possible health effects. Before building new facilities it is necessary to assess whether these would meet the requirements of the regulations. Thus it is necessary to have tools that quantify the MF values emitted by the planned facilities. In the laying of cables, two zones are identified. The first one is where the phases are regularly laid close to each other. The other area is where the joints are made. In this area is where the distances between phases are higher. In the latter, the magnetic field values are higher due to the increase of the separation.
publishDate 2016
dc.date.none.fl_str_mv 2016-08
dc.type.none.fl_str_mv info:eu-repo/semantics/conferenceObject
info:eu-repo/semantics/publishedVersion
Resumen
http://purl.org/coar/resource_type/c_5794
info:ar-repo/semantics/documentoDeConferencia
format conferenceObject
status_str publishedVersion
dc.identifier.none.fl_str_mv http://sedici.unlp.edu.ar/handle/10915/67665
url http://sedici.unlp.edu.ar/handle/10915/67665
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://app.box.com/s/7qryg6t4qxpysi66maandups78dbegrl
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
http://creativecommons.org/licenses/by-nc-nd/4.0/
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:SEDICI (UNLP)
instname:Universidad Nacional de La Plata
instacron:UNLP
reponame_str SEDICI (UNLP)
collection SEDICI (UNLP)
instname_str Universidad Nacional de La Plata
instacron_str UNLP
institution UNLP
repository.name.fl_str_mv SEDICI (UNLP) - Universidad Nacional de La Plata
repository.mail.fl_str_mv alira@sedici.unlp.edu.ar
_version_ 1846064075387174912
score 13.22299