Spectral analysis o f the 4d<SUP>9</SUP>6s configuration in eight times ionized xenon (Xe IX)
- Autores
- Raineri, María Mónica; Gallardo, Mario O.; Reyna Almandos, Jorge Guillermo
- Año de publicación
- 2006
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- A capillary light source was used to observe the spectrum of eight times ionized xenon, Xe IX, in the vacuum ultraviolet range, 270 2000 Å. Sixteen transitions have been identified as combinations between energy levels of the 4d96s with 4d95p configuration, and all 4d96s levels have been determined. The present analysis is based on an accurate extrapolation of energy parameters and experimental energy level values in the Pd I isoelectronic sequence. The energy parameters were obtained with Hartree-Fock relativistic calculations. Least squares parametric calculation has been carried out to study the fit between experimental and theoretical values.
Facultad de Ciencias Exactas
Centro de Investigaciones Ópticas - Materia
-
Física
Capillary light source
Spectrum
Eight times ionized xenon - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- http://creativecommons.org/licenses/by/4.0/
- Repositorio
- Institución
- Universidad Nacional de La Plata
- OAI Identificador
- oai:sedici.unlp.edu.ar:10915/91594
Ver los metadatos del registro completo
id |
SEDICI_35979567e5252a29f4f552ad293bc2cc |
---|---|
oai_identifier_str |
oai:sedici.unlp.edu.ar:10915/91594 |
network_acronym_str |
SEDICI |
repository_id_str |
1329 |
network_name_str |
SEDICI (UNLP) |
spelling |
Spectral analysis o f the 4d<SUP>9</SUP>6s configuration in eight times ionized xenon (Xe IX)Raineri, María MónicaGallardo, Mario O.Reyna Almandos, Jorge GuillermoFísicaCapillary light sourceSpectrumEight times ionized xenonA capillary light source was used to observe the spectrum of eight times ionized xenon, Xe IX, in the vacuum ultraviolet range, 270 2000 Å. Sixteen transitions have been identified as combinations between energy levels of the 4d96s with 4d95p configuration, and all 4d96s levels have been determined. The present analysis is based on an accurate extrapolation of energy parameters and experimental energy level values in the Pd I isoelectronic sequence. The energy parameters were obtained with Hartree-Fock relativistic calculations. Least squares parametric calculation has been carried out to study the fit between experimental and theoretical values.Facultad de Ciencias ExactasCentro de Investigaciones Ópticas2006info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArticulohttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdf391-395http://sedici.unlp.edu.ar/handle/10915/91594enginfo:eu-repo/semantics/altIdentifier/hdl/11746/371info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by/4.0/Creative Commons Attribution 4.0 International (CC BY 4.0)reponame:SEDICI (UNLP)instname:Universidad Nacional de La Platainstacron:UNLP2025-09-29T11:19:07Zoai:sedici.unlp.edu.ar:10915/91594Institucionalhttp://sedici.unlp.edu.ar/Universidad públicaNo correspondehttp://sedici.unlp.edu.ar/oai/snrdalira@sedici.unlp.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:13292025-09-29 11:19:07.505SEDICI (UNLP) - Universidad Nacional de La Platafalse |
dc.title.none.fl_str_mv |
Spectral analysis o f the 4d<SUP>9</SUP>6s configuration in eight times ionized xenon (Xe IX) |
title |
Spectral analysis o f the 4d<SUP>9</SUP>6s configuration in eight times ionized xenon (Xe IX) |
spellingShingle |
Spectral analysis o f the 4d<SUP>9</SUP>6s configuration in eight times ionized xenon (Xe IX) Raineri, María Mónica Física Capillary light source Spectrum Eight times ionized xenon |
title_short |
Spectral analysis o f the 4d<SUP>9</SUP>6s configuration in eight times ionized xenon (Xe IX) |
title_full |
Spectral analysis o f the 4d<SUP>9</SUP>6s configuration in eight times ionized xenon (Xe IX) |
title_fullStr |
Spectral analysis o f the 4d<SUP>9</SUP>6s configuration in eight times ionized xenon (Xe IX) |
title_full_unstemmed |
Spectral analysis o f the 4d<SUP>9</SUP>6s configuration in eight times ionized xenon (Xe IX) |
title_sort |
Spectral analysis o f the 4d<SUP>9</SUP>6s configuration in eight times ionized xenon (Xe IX) |
dc.creator.none.fl_str_mv |
Raineri, María Mónica Gallardo, Mario O. Reyna Almandos, Jorge Guillermo |
author |
Raineri, María Mónica |
author_facet |
Raineri, María Mónica Gallardo, Mario O. Reyna Almandos, Jorge Guillermo |
author_role |
author |
author2 |
Gallardo, Mario O. Reyna Almandos, Jorge Guillermo |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Física Capillary light source Spectrum Eight times ionized xenon |
topic |
Física Capillary light source Spectrum Eight times ionized xenon |
dc.description.none.fl_txt_mv |
A capillary light source was used to observe the spectrum of eight times ionized xenon, Xe IX, in the vacuum ultraviolet range, 270 2000 Å. Sixteen transitions have been identified as combinations between energy levels of the 4d96s with 4d95p configuration, and all 4d96s levels have been determined. The present analysis is based on an accurate extrapolation of energy parameters and experimental energy level values in the Pd I isoelectronic sequence. The energy parameters were obtained with Hartree-Fock relativistic calculations. Least squares parametric calculation has been carried out to study the fit between experimental and theoretical values. Facultad de Ciencias Exactas Centro de Investigaciones Ópticas |
description |
A capillary light source was used to observe the spectrum of eight times ionized xenon, Xe IX, in the vacuum ultraviolet range, 270 2000 Å. Sixteen transitions have been identified as combinations between energy levels of the 4d96s with 4d95p configuration, and all 4d96s levels have been determined. The present analysis is based on an accurate extrapolation of energy parameters and experimental energy level values in the Pd I isoelectronic sequence. The energy parameters were obtained with Hartree-Fock relativistic calculations. Least squares parametric calculation has been carried out to study the fit between experimental and theoretical values. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Articulo http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://sedici.unlp.edu.ar/handle/10915/91594 |
url |
http://sedici.unlp.edu.ar/handle/10915/91594 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/hdl/11746/371 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/4.0/ Creative Commons Attribution 4.0 International (CC BY 4.0) |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by/4.0/ Creative Commons Attribution 4.0 International (CC BY 4.0) |
dc.format.none.fl_str_mv |
application/pdf 391-395 |
dc.source.none.fl_str_mv |
reponame:SEDICI (UNLP) instname:Universidad Nacional de La Plata instacron:UNLP |
reponame_str |
SEDICI (UNLP) |
collection |
SEDICI (UNLP) |
instname_str |
Universidad Nacional de La Plata |
instacron_str |
UNLP |
institution |
UNLP |
repository.name.fl_str_mv |
SEDICI (UNLP) - Universidad Nacional de La Plata |
repository.mail.fl_str_mv |
alira@sedici.unlp.edu.ar |
_version_ |
1844616064804061184 |
score |
13.070432 |