Spectral analysis o f the $latex 4d^{9}6s$ configuration in eight times ionized xenon, Xe IX
- Autores
- Raineri, María Mónica; Gallardo, Mario; Reyna Almandos, Jorge Guillermo
- Año de publicación
- 2006
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión enviada
- Descripción
- A capillary light source was used to observe the spectrum of eight times ionized xenon, Xe IX, in the vacuum ultraviolet range, 270 2000 Å. Sixteen transitions have been identified as combinations between energy levels of the $latex 4d^{9}6s$ with $latex 4d^{9}5p$ configuration, and all $latex 4d^{9}6s$ levels have been determined. The present analysis is based on an accurate extrapolation of energy parameters and experimental energy level values in the Pd I isoelectronic sequence. The energy parameters were obtained with Hartree-Fock relativistic calculations. Least squares parametric calculation has been carried out to study the fit between experimental and theoretical values.
- Materia
-
Ciencias Físicas
capillary light source
spectrum
eight times ionized xenon, - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- http://creativecommons.org/licenses/by/4.0/
- Repositorio
- Institución
- Comisión de Investigaciones Científicas de la Provincia de Buenos Aires
- OAI Identificador
- oai:digital.cic.gba.gob.ar:11746/371
Ver los metadatos del registro completo
id |
CICBA_22299cd0f5988bbd2e12f763491066d3 |
---|---|
oai_identifier_str |
oai:digital.cic.gba.gob.ar:11746/371 |
network_acronym_str |
CICBA |
repository_id_str |
9441 |
network_name_str |
CIC Digital (CICBA) |
spelling |
Spectral analysis o f the $latex 4d^{9}6s$ configuration in eight times ionized xenon, Xe IXRaineri, María MónicaGallardo, MarioReyna Almandos, Jorge GuillermoCiencias Físicascapillary light sourcespectrumeight times ionized xenon,A capillary light source was used to observe the spectrum of eight times ionized xenon, Xe IX, in the vacuum ultraviolet range, 270 2000 Å. Sixteen transitions have been identified as combinations between energy levels of the $latex 4d^{9}6s$ with $latex 4d^{9}5p$ configuration, and all $latex 4d^{9}6s$ levels have been determined. The present analysis is based on an accurate extrapolation of energy parameters and experimental energy level values in the Pd I isoelectronic sequence. The energy parameters were obtained with Hartree-Fock relativistic calculations. Least squares parametric calculation has been carried out to study the fit between experimental and theoretical values.2006info:eu-repo/semantics/articleinfo:eu-repo/semantics/submittedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfhttps://digital.cic.gba.gob.ar/handle/11746/371enghttp://digital.cic.gba.gob.ar/handle/123456789/68info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by/4.0/reponame:CIC Digital (CICBA)instname:Comisión de Investigaciones Científicas de la Provincia de Buenos Airesinstacron:CICBA2025-09-29T13:40:02Zoai:digital.cic.gba.gob.ar:11746/371Institucionalhttp://digital.cic.gba.gob.arOrganismo científico-tecnológicoNo correspondehttp://digital.cic.gba.gob.ar/oai/snrdmarisa.degiusti@sedici.unlp.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:94412025-09-29 13:40:02.768CIC Digital (CICBA) - Comisión de Investigaciones Científicas de la Provincia de Buenos Airesfalse |
dc.title.none.fl_str_mv |
Spectral analysis o f the $latex 4d^{9}6s$ configuration in eight times ionized xenon, Xe IX |
title |
Spectral analysis o f the $latex 4d^{9}6s$ configuration in eight times ionized xenon, Xe IX |
spellingShingle |
Spectral analysis o f the $latex 4d^{9}6s$ configuration in eight times ionized xenon, Xe IX Raineri, María Mónica Ciencias Físicas capillary light source spectrum eight times ionized xenon, |
title_short |
Spectral analysis o f the $latex 4d^{9}6s$ configuration in eight times ionized xenon, Xe IX |
title_full |
Spectral analysis o f the $latex 4d^{9}6s$ configuration in eight times ionized xenon, Xe IX |
title_fullStr |
Spectral analysis o f the $latex 4d^{9}6s$ configuration in eight times ionized xenon, Xe IX |
title_full_unstemmed |
Spectral analysis o f the $latex 4d^{9}6s$ configuration in eight times ionized xenon, Xe IX |
title_sort |
Spectral analysis o f the $latex 4d^{9}6s$ configuration in eight times ionized xenon, Xe IX |
dc.creator.none.fl_str_mv |
Raineri, María Mónica Gallardo, Mario Reyna Almandos, Jorge Guillermo |
author |
Raineri, María Mónica |
author_facet |
Raineri, María Mónica Gallardo, Mario Reyna Almandos, Jorge Guillermo |
author_role |
author |
author2 |
Gallardo, Mario Reyna Almandos, Jorge Guillermo |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Ciencias Físicas capillary light source spectrum eight times ionized xenon, |
topic |
Ciencias Físicas capillary light source spectrum eight times ionized xenon, |
dc.description.none.fl_txt_mv |
A capillary light source was used to observe the spectrum of eight times ionized xenon, Xe IX, in the vacuum ultraviolet range, 270 2000 Å. Sixteen transitions have been identified as combinations between energy levels of the $latex 4d^{9}6s$ with $latex 4d^{9}5p$ configuration, and all $latex 4d^{9}6s$ levels have been determined. The present analysis is based on an accurate extrapolation of energy parameters and experimental energy level values in the Pd I isoelectronic sequence. The energy parameters were obtained with Hartree-Fock relativistic calculations. Least squares parametric calculation has been carried out to study the fit between experimental and theoretical values. |
description |
A capillary light source was used to observe the spectrum of eight times ionized xenon, Xe IX, in the vacuum ultraviolet range, 270 2000 Å. Sixteen transitions have been identified as combinations between energy levels of the $latex 4d^{9}6s$ with $latex 4d^{9}5p$ configuration, and all $latex 4d^{9}6s$ levels have been determined. The present analysis is based on an accurate extrapolation of energy parameters and experimental energy level values in the Pd I isoelectronic sequence. The energy parameters were obtained with Hartree-Fock relativistic calculations. Least squares parametric calculation has been carried out to study the fit between experimental and theoretical values. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/submittedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
submittedVersion |
dc.identifier.none.fl_str_mv |
https://digital.cic.gba.gob.ar/handle/11746/371 |
url |
https://digital.cic.gba.gob.ar/handle/11746/371 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://digital.cic.gba.gob.ar/handle/123456789/68 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by/4.0/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by/4.0/ |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:CIC Digital (CICBA) instname:Comisión de Investigaciones Científicas de la Provincia de Buenos Aires instacron:CICBA |
reponame_str |
CIC Digital (CICBA) |
collection |
CIC Digital (CICBA) |
instname_str |
Comisión de Investigaciones Científicas de la Provincia de Buenos Aires |
instacron_str |
CICBA |
institution |
CICBA |
repository.name.fl_str_mv |
CIC Digital (CICBA) - Comisión de Investigaciones Científicas de la Provincia de Buenos Aires |
repository.mail.fl_str_mv |
marisa.degiusti@sedici.unlp.edu.ar |
_version_ |
1844618595486662656 |
score |
13.070432 |