Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article
- Autores
- Tucceri, Ismael Ricardo
- Año de publicación
- 2017
- Idioma
- inglés
- Tipo de recurso
- reseña artículo
- Estado
- versión publicada
- Descripción
- Electrochemical and chemical treatments, such as, storage time without use (STWU), prolonged potential cycling (PPC), high positive potential limits (HPPL) and soaking in a ferric ion solution (SFeIS), affect the conduction properties of poly (o-aminophenol) (POAP). The effect of these treatments on the conducting properties of POAP was studied employing cyclic voltammetry (CV), rotating disc electrode voltammetry (RDEV), electrochemical impedance spectroscopy (EIS) and surface resistance (SR). A review of these studies is presented in this work.
Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas - Materia
-
Química
Poly(o-aminophenol) film electrodes
Deactivation
Storage time without use
Prolonged potential cycling - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- http://creativecommons.org/licenses/by-nc-sa/4.0/
- Repositorio
- Institución
- Universidad Nacional de La Plata
- OAI Identificador
- oai:sedici.unlp.edu.ar:10915/96099
Ver los metadatos del registro completo
id |
SEDICI_2c63845b3ff38ec3670c4ee4a3e039c4 |
---|---|
oai_identifier_str |
oai:sedici.unlp.edu.ar:10915/96099 |
network_acronym_str |
SEDICI |
repository_id_str |
1329 |
network_name_str |
SEDICI (UNLP) |
spelling |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review articleTucceri, Ismael RicardoQuímicaPoly(o-aminophenol) film electrodesDeactivationStorage time without useProlonged potential cyclingElectrochemical and chemical treatments, such as, storage time without use (STWU), prolonged potential cycling (PPC), high positive potential limits (HPPL) and soaking in a ferric ion solution (SFeIS), affect the conduction properties of poly (o-aminophenol) (POAP). The effect of these treatments on the conducting properties of POAP was studied employing cyclic voltammetry (CV), rotating disc electrode voltammetry (RDEV), electrochemical impedance spectroscopy (EIS) and surface resistance (SR). A review of these studies is presented in this work.Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas2017-12info:eu-repo/semantics/reviewinfo:eu-repo/semantics/publishedVersionRevisionhttp://purl.org/coar/resource_type/c_dcae04bcinfo:ar-repo/semantics/resenaArticuloapplication/pdf122-134http://sedici.unlp.edu.ar/handle/10915/96099enginfo:eu-repo/semantics/altIdentifier/url/https://ri.conicet.gov.ar/11336/64288info:eu-repo/semantics/altIdentifier/url/http://ajpamc.com/article/POLY%20(O-AMINOPHENOL)%20A%20POLYMER%20EMPLOYED%20AS%20MATERIAL%20OF%20BIOSENSORS.%20ITS%20DEACTIVATION.%20A%20REVIEW%20ARTICLE.pdfinfo:eu-repo/semantics/altIdentifier/issn/2321-0923info:eu-repo/semantics/altIdentifier/hdl/11336/64288info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-sa/4.0/Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)reponame:SEDICI (UNLP)instname:Universidad Nacional de La Platainstacron:UNLP2025-09-29T11:20:16Zoai:sedici.unlp.edu.ar:10915/96099Institucionalhttp://sedici.unlp.edu.ar/Universidad públicaNo correspondehttp://sedici.unlp.edu.ar/oai/snrdalira@sedici.unlp.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:13292025-09-29 11:20:17.16SEDICI (UNLP) - Universidad Nacional de La Platafalse |
dc.title.none.fl_str_mv |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
title |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
spellingShingle |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article Tucceri, Ismael Ricardo Química Poly(o-aminophenol) film electrodes Deactivation Storage time without use Prolonged potential cycling |
title_short |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
title_full |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
title_fullStr |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
title_full_unstemmed |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
title_sort |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
dc.creator.none.fl_str_mv |
Tucceri, Ismael Ricardo |
author |
Tucceri, Ismael Ricardo |
author_facet |
Tucceri, Ismael Ricardo |
author_role |
author |
dc.subject.none.fl_str_mv |
Química Poly(o-aminophenol) film electrodes Deactivation Storage time without use Prolonged potential cycling |
topic |
Química Poly(o-aminophenol) film electrodes Deactivation Storage time without use Prolonged potential cycling |
dc.description.none.fl_txt_mv |
Electrochemical and chemical treatments, such as, storage time without use (STWU), prolonged potential cycling (PPC), high positive potential limits (HPPL) and soaking in a ferric ion solution (SFeIS), affect the conduction properties of poly (o-aminophenol) (POAP). The effect of these treatments on the conducting properties of POAP was studied employing cyclic voltammetry (CV), rotating disc electrode voltammetry (RDEV), electrochemical impedance spectroscopy (EIS) and surface resistance (SR). A review of these studies is presented in this work. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas |
description |
Electrochemical and chemical treatments, such as, storage time without use (STWU), prolonged potential cycling (PPC), high positive potential limits (HPPL) and soaking in a ferric ion solution (SFeIS), affect the conduction properties of poly (o-aminophenol) (POAP). The effect of these treatments on the conducting properties of POAP was studied employing cyclic voltammetry (CV), rotating disc electrode voltammetry (RDEV), electrochemical impedance spectroscopy (EIS) and surface resistance (SR). A review of these studies is presented in this work. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-12 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/review info:eu-repo/semantics/publishedVersion Revision http://purl.org/coar/resource_type/c_dcae04bc info:ar-repo/semantics/resenaArticulo |
format |
review |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://sedici.unlp.edu.ar/handle/10915/96099 |
url |
http://sedici.unlp.edu.ar/handle/10915/96099 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://ri.conicet.gov.ar/11336/64288 info:eu-repo/semantics/altIdentifier/url/http://ajpamc.com/article/POLY%20(O-AMINOPHENOL)%20A%20POLYMER%20EMPLOYED%20AS%20MATERIAL%20OF%20BIOSENSORS.%20ITS%20DEACTIVATION.%20A%20REVIEW%20ARTICLE.pdf info:eu-repo/semantics/altIdentifier/issn/2321-0923 info:eu-repo/semantics/altIdentifier/hdl/11336/64288 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by-nc-sa/4.0/ Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-sa/4.0/ Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) |
dc.format.none.fl_str_mv |
application/pdf 122-134 |
dc.source.none.fl_str_mv |
reponame:SEDICI (UNLP) instname:Universidad Nacional de La Plata instacron:UNLP |
reponame_str |
SEDICI (UNLP) |
collection |
SEDICI (UNLP) |
instname_str |
Universidad Nacional de La Plata |
instacron_str |
UNLP |
institution |
UNLP |
repository.name.fl_str_mv |
SEDICI (UNLP) - Universidad Nacional de La Plata |
repository.mail.fl_str_mv |
alira@sedici.unlp.edu.ar |
_version_ |
1844616077426819072 |
score |
13.070432 |