- Electrochemical and chemical treatments, such as, storage time without use (STWU), prolonged potential cycling (PPC), high positive potential limits (HPPL) and soaking in a ferric ion solution (SFeIS), affect the conduction properties of poly (o-aminophenol) (POAP). The effect of these treatments on the conducting properties of POAP was studied employing cyclic voltammetry (CV), rotating disc electrode voltammetry (RDEV), electrochemical impedance spectroscopy (EIS) and surface resistance (SR). A review of these studies is presented in this work.
Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas - Materia
-
Química
Poly(o-aminophenol) film electrodes
Deactivation
Storage time without use
Prolonged potential cycling - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- http://creativecommons.org/licenses/by-nc-sa/4.0/
- Repositorio
.jpg)
- Institución
- Universidad Nacional de La Plata
- OAI Identificador
- oai:sedici.unlp.edu.ar:10915/96099
Ver los metadatos del registro completo
| id |
SEDICI_2c63845b3ff38ec3670c4ee4a3e039c4 |
|---|---|
| oai_identifier_str |
oai:sedici.unlp.edu.ar:10915/96099 |
| network_acronym_str |
SEDICI |
| repository_id_str |
1329 |
| network_name_str |
SEDICI (UNLP) |
| spelling |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review articleTucceri, Ismael RicardoQuímicaPoly(o-aminophenol) film electrodesDeactivationStorage time without useProlonged potential cyclingElectrochemical and chemical treatments, such as, storage time without use (STWU), prolonged potential cycling (PPC), high positive potential limits (HPPL) and soaking in a ferric ion solution (SFeIS), affect the conduction properties of poly (o-aminophenol) (POAP). The effect of these treatments on the conducting properties of POAP was studied employing cyclic voltammetry (CV), rotating disc electrode voltammetry (RDEV), electrochemical impedance spectroscopy (EIS) and surface resistance (SR). A review of these studies is presented in this work.Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas2017-12info:eu-repo/semantics/reviewinfo:eu-repo/semantics/publishedVersionRevisionhttp://purl.org/coar/resource_type/c_dcae04bcinfo:ar-repo/semantics/resenaArticuloapplication/pdf122-134http://sedici.unlp.edu.ar/handle/10915/96099enginfo:eu-repo/semantics/altIdentifier/url/https://ri.conicet.gov.ar/11336/64288info:eu-repo/semantics/altIdentifier/url/http://ajpamc.com/article/POLY%20(O-AMINOPHENOL)%20A%20POLYMER%20EMPLOYED%20AS%20MATERIAL%20OF%20BIOSENSORS.%20ITS%20DEACTIVATION.%20A%20REVIEW%20ARTICLE.pdfinfo:eu-repo/semantics/altIdentifier/issn/2321-0923info:eu-repo/semantics/altIdentifier/hdl/11336/64288info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-sa/4.0/Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)reponame:SEDICI (UNLP)instname:Universidad Nacional de La Platainstacron:UNLP2025-10-22T17:01:10Zoai:sedici.unlp.edu.ar:10915/96099Institucionalhttp://sedici.unlp.edu.ar/Universidad públicaNo correspondehttp://sedici.unlp.edu.ar/oai/snrdalira@sedici.unlp.edu.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:13292025-10-22 17:01:10.547SEDICI (UNLP) - Universidad Nacional de La Platafalse |
| dc.title.none.fl_str_mv |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
| title |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
| spellingShingle |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article Tucceri, Ismael Ricardo Química Poly(o-aminophenol) film electrodes Deactivation Storage time without use Prolonged potential cycling |
| title_short |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
| title_full |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
| title_fullStr |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
| title_full_unstemmed |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
| title_sort |
Poly(o-aminophenol) a polymer employed as material of biosensors: Its deactivation : A review article |
| dc.creator.none.fl_str_mv |
Tucceri, Ismael Ricardo |
| author |
Tucceri, Ismael Ricardo |
| author_facet |
Tucceri, Ismael Ricardo |
| author_role |
author |
| dc.subject.none.fl_str_mv |
Química Poly(o-aminophenol) film electrodes Deactivation Storage time without use Prolonged potential cycling |
| topic |
Química Poly(o-aminophenol) film electrodes Deactivation Storage time without use Prolonged potential cycling |
| dc.description.none.fl_txt_mv |
Electrochemical and chemical treatments, such as, storage time without use (STWU), prolonged potential cycling (PPC), high positive potential limits (HPPL) and soaking in a ferric ion solution (SFeIS), affect the conduction properties of poly (o-aminophenol) (POAP). The effect of these treatments on the conducting properties of POAP was studied employing cyclic voltammetry (CV), rotating disc electrode voltammetry (RDEV), electrochemical impedance spectroscopy (EIS) and surface resistance (SR). A review of these studies is presented in this work. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas |
| description |
Electrochemical and chemical treatments, such as, storage time without use (STWU), prolonged potential cycling (PPC), high positive potential limits (HPPL) and soaking in a ferric ion solution (SFeIS), affect the conduction properties of poly (o-aminophenol) (POAP). The effect of these treatments on the conducting properties of POAP was studied employing cyclic voltammetry (CV), rotating disc electrode voltammetry (RDEV), electrochemical impedance spectroscopy (EIS) and surface resistance (SR). A review of these studies is presented in this work. |
| publishDate |
2017 |
| dc.date.none.fl_str_mv |
2017-12 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/review info:eu-repo/semantics/publishedVersion Revision http://purl.org/coar/resource_type/c_dcae04bc info:ar-repo/semantics/resenaArticulo |
| format |
review |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://sedici.unlp.edu.ar/handle/10915/96099 |
| url |
http://sedici.unlp.edu.ar/handle/10915/96099 |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://ri.conicet.gov.ar/11336/64288 info:eu-repo/semantics/altIdentifier/url/http://ajpamc.com/article/POLY%20(O-AMINOPHENOL)%20A%20POLYMER%20EMPLOYED%20AS%20MATERIAL%20OF%20BIOSENSORS.%20ITS%20DEACTIVATION.%20A%20REVIEW%20ARTICLE.pdf info:eu-repo/semantics/altIdentifier/issn/2321-0923 info:eu-repo/semantics/altIdentifier/hdl/11336/64288 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by-nc-sa/4.0/ Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-sa/4.0/ Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) |
| dc.format.none.fl_str_mv |
application/pdf 122-134 |
| dc.source.none.fl_str_mv |
reponame:SEDICI (UNLP) instname:Universidad Nacional de La Plata instacron:UNLP |
| reponame_str |
SEDICI (UNLP) |
| collection |
SEDICI (UNLP) |
| instname_str |
Universidad Nacional de La Plata |
| instacron_str |
UNLP |
| institution |
UNLP |
| repository.name.fl_str_mv |
SEDICI (UNLP) - Universidad Nacional de La Plata |
| repository.mail.fl_str_mv |
alira@sedici.unlp.edu.ar |
| _version_ |
1846783258152402944 |
| score |
12.982451 |