Poly(o-aminophenol): a polymer employed as material of biosensors: Its deactivation. A review article
- Autores
- Tucceri, Ismael Ricardo
- Año de publicación
- 2017
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Electrochemical and chemical treatments, such as, storage time without use (STWU), prolonged potential cycling (PPC), high positive potential limits (HPPL) and soaking in a ferric ion solution (SFeIS), affect the conduction properties of poly (o-aminophenol) (POAP). The effect of these treatments on the conducting properties of POAP was studied employing cyclic voltammetry (CV), rotating disc electrode voltammetry (RDEV), electrochemical impedance spectroscopy (EIS) and surface resistance (SR). A review of these studies is presented in this work.
Fil: Tucceri, Ismael Ricardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina - Materia
-
Poly(o-aminophenol) film electrodes
Deactivation
Storage time without use
Prolonged potential cycling - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/64288
Ver los metadatos del registro completo
id |
CONICETDig_80535314e57edef9fc931f1899692fb9 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/64288 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Poly(o-aminophenol): a polymer employed as material of biosensors: Its deactivation. A review articleTucceri, Ismael RicardoPoly(o-aminophenol) film electrodesDeactivationStorage time without useProlonged potential cyclinghttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1Electrochemical and chemical treatments, such as, storage time without use (STWU), prolonged potential cycling (PPC), high positive potential limits (HPPL) and soaking in a ferric ion solution (SFeIS), affect the conduction properties of poly (o-aminophenol) (POAP). The effect of these treatments on the conducting properties of POAP was studied employing cyclic voltammetry (CV), rotating disc electrode voltammetry (RDEV), electrochemical impedance spectroscopy (EIS) and surface resistance (SR). A review of these studies is presented in this work.Fil: Tucceri, Ismael Ricardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; ArgentinaUptodate Research Publication2017-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/64288Tucceri, Ismael Ricardo; Poly(o-aminophenol): a polymer employed as material of biosensors: Its deactivation. A review article; Uptodate Research Publication; Assian Journal of Pharmaceutical Analysis and Medicinal Chemistry,; 5; 3; 12-2017; 122-1342321-0923CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://ajpamc.com/article/POLY%20(O-AMINOPHENOL)%20A%20POLYMER%20EMPLOYED%20AS%20MATERIAL%20OF%20BIOSENSORS.%20ITS%20DEACTIVATION.%20A%20REVIEW%20ARTICLE.pdfinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T09:35:57Zoai:ri.conicet.gov.ar:11336/64288instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 09:35:58.131CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Poly(o-aminophenol): a polymer employed as material of biosensors: Its deactivation. A review article |
title |
Poly(o-aminophenol): a polymer employed as material of biosensors: Its deactivation. A review article |
spellingShingle |
Poly(o-aminophenol): a polymer employed as material of biosensors: Its deactivation. A review article Tucceri, Ismael Ricardo Poly(o-aminophenol) film electrodes Deactivation Storage time without use Prolonged potential cycling |
title_short |
Poly(o-aminophenol): a polymer employed as material of biosensors: Its deactivation. A review article |
title_full |
Poly(o-aminophenol): a polymer employed as material of biosensors: Its deactivation. A review article |
title_fullStr |
Poly(o-aminophenol): a polymer employed as material of biosensors: Its deactivation. A review article |
title_full_unstemmed |
Poly(o-aminophenol): a polymer employed as material of biosensors: Its deactivation. A review article |
title_sort |
Poly(o-aminophenol): a polymer employed as material of biosensors: Its deactivation. A review article |
dc.creator.none.fl_str_mv |
Tucceri, Ismael Ricardo |
author |
Tucceri, Ismael Ricardo |
author_facet |
Tucceri, Ismael Ricardo |
author_role |
author |
dc.subject.none.fl_str_mv |
Poly(o-aminophenol) film electrodes Deactivation Storage time without use Prolonged potential cycling |
topic |
Poly(o-aminophenol) film electrodes Deactivation Storage time without use Prolonged potential cycling |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
Electrochemical and chemical treatments, such as, storage time without use (STWU), prolonged potential cycling (PPC), high positive potential limits (HPPL) and soaking in a ferric ion solution (SFeIS), affect the conduction properties of poly (o-aminophenol) (POAP). The effect of these treatments on the conducting properties of POAP was studied employing cyclic voltammetry (CV), rotating disc electrode voltammetry (RDEV), electrochemical impedance spectroscopy (EIS) and surface resistance (SR). A review of these studies is presented in this work. Fil: Tucceri, Ismael Ricardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina |
description |
Electrochemical and chemical treatments, such as, storage time without use (STWU), prolonged potential cycling (PPC), high positive potential limits (HPPL) and soaking in a ferric ion solution (SFeIS), affect the conduction properties of poly (o-aminophenol) (POAP). The effect of these treatments on the conducting properties of POAP was studied employing cyclic voltammetry (CV), rotating disc electrode voltammetry (RDEV), electrochemical impedance spectroscopy (EIS) and surface resistance (SR). A review of these studies is presented in this work. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-12 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/64288 Tucceri, Ismael Ricardo; Poly(o-aminophenol): a polymer employed as material of biosensors: Its deactivation. A review article; Uptodate Research Publication; Assian Journal of Pharmaceutical Analysis and Medicinal Chemistry,; 5; 3; 12-2017; 122-134 2321-0923 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/64288 |
identifier_str_mv |
Tucceri, Ismael Ricardo; Poly(o-aminophenol): a polymer employed as material of biosensors: Its deactivation. A review article; Uptodate Research Publication; Assian Journal of Pharmaceutical Analysis and Medicinal Chemistry,; 5; 3; 12-2017; 122-134 2321-0923 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/http://ajpamc.com/article/POLY%20(O-AMINOPHENOL)%20A%20POLYMER%20EMPLOYED%20AS%20MATERIAL%20OF%20BIOSENSORS.%20ITS%20DEACTIVATION.%20A%20REVIEW%20ARTICLE.pdf |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Uptodate Research Publication |
publisher.none.fl_str_mv |
Uptodate Research Publication |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844613124663017472 |
score |
13.070432 |