Solid-phase preconcentration and determination of mercury(II) using activated carbon in drinking water by X-ray fluorescence spectrometry
- Autores
- Aranda, Pedro Rodolfo; Colombo, Leandro; Perino, Ernesto; de Vito, Irma Esther; Raba, Julio
- Año de publicación
- 2013
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- A novel and simple method was developed for the preconcentration and determination of mercury(II) from hydrochloric acid solutions through their adsorption on Aliquat 336 (tri-octylmethylammonium chloride)-activated carbon. The determinations were made directly on the solid by X-ray fluorescence spectrometry, which had the advantage of eliminating the step of elution of the mercury retained. This preconcentration system enabled the determination of Hg(II) in drinking water samples at µg l−1 levels. A 1700-fold enrichment factor was obtained. The described methodology showed excellent reproducibility, accuracy, and detection limits improvement by eliminating the step of elution of the analyte, replacing those methods based on cold vapor generation, reducing reagent consumption, and handling of samples.
Fil: Aranda, Pedro Rodolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina
Fil: Colombo, Leandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina
Fil: Perino, Ernesto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina
Fil: de Vito, Irma Esther. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina
Fil: Raba, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina - Materia
-
Solid-Phase
Mercury(Ii)
X-Ray Fluorescence
Spectrometry - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/5791
Ver los metadatos del registro completo
id |
CONICETDig_f7b1019101bde1482611146d5cd3fa7d |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/5791 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Solid-phase preconcentration and determination of mercury(II) using activated carbon in drinking water by X-ray fluorescence spectrometryAranda, Pedro RodolfoColombo, LeandroPerino, Ernestode Vito, Irma EstherRaba, JulioSolid-PhaseMercury(Ii)X-Ray FluorescenceSpectrometryhttps://purl.org/becyt/ford/1.4https://purl.org/becyt/ford/1A novel and simple method was developed for the preconcentration and determination of mercury(II) from hydrochloric acid solutions through their adsorption on Aliquat 336 (tri-octylmethylammonium chloride)-activated carbon. The determinations were made directly on the solid by X-ray fluorescence spectrometry, which had the advantage of eliminating the step of elution of the mercury retained. This preconcentration system enabled the determination of Hg(II) in drinking water samples at µg l−1 levels. A 1700-fold enrichment factor was obtained. The described methodology showed excellent reproducibility, accuracy, and detection limits improvement by eliminating the step of elution of the analyte, replacing those methods based on cold vapor generation, reducing reagent consumption, and handling of samples.Fil: Aranda, Pedro Rodolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; ArgentinaFil: Colombo, Leandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; ArgentinaFil: Perino, Ernesto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; ArgentinaFil: de Vito, Irma Esther. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; ArgentinaFil: Raba, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; ArgentinaWiley2013-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/5791Aranda, Pedro Rodolfo; Colombo, Leandro; Perino, Ernesto; de Vito, Irma Esther; Raba, Julio; Solid-phase preconcentration and determination of mercury(II) using activated carbon in drinking water by X-ray fluorescence spectrometry; Wiley; X-ray Spectrometry; 42; 2; 1-2013; 100-1040049-8246enginfo:eu-repo/semantics/altIdentifier/url/http://onlinelibrary.wiley.com/doi/10.1002/xrs.2440/abstractinfo:eu-repo/semantics/altIdentifier/doi/info:eu-repo/semantics/altIdentifier/doi/10.1002/xrs.2440info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:00:25Zoai:ri.conicet.gov.ar:11336/5791instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:00:25.664CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Solid-phase preconcentration and determination of mercury(II) using activated carbon in drinking water by X-ray fluorescence spectrometry |
title |
Solid-phase preconcentration and determination of mercury(II) using activated carbon in drinking water by X-ray fluorescence spectrometry |
spellingShingle |
Solid-phase preconcentration and determination of mercury(II) using activated carbon in drinking water by X-ray fluorescence spectrometry Aranda, Pedro Rodolfo Solid-Phase Mercury(Ii) X-Ray Fluorescence Spectrometry |
title_short |
Solid-phase preconcentration and determination of mercury(II) using activated carbon in drinking water by X-ray fluorescence spectrometry |
title_full |
Solid-phase preconcentration and determination of mercury(II) using activated carbon in drinking water by X-ray fluorescence spectrometry |
title_fullStr |
Solid-phase preconcentration and determination of mercury(II) using activated carbon in drinking water by X-ray fluorescence spectrometry |
title_full_unstemmed |
Solid-phase preconcentration and determination of mercury(II) using activated carbon in drinking water by X-ray fluorescence spectrometry |
title_sort |
Solid-phase preconcentration and determination of mercury(II) using activated carbon in drinking water by X-ray fluorescence spectrometry |
dc.creator.none.fl_str_mv |
Aranda, Pedro Rodolfo Colombo, Leandro Perino, Ernesto de Vito, Irma Esther Raba, Julio |
author |
Aranda, Pedro Rodolfo |
author_facet |
Aranda, Pedro Rodolfo Colombo, Leandro Perino, Ernesto de Vito, Irma Esther Raba, Julio |
author_role |
author |
author2 |
Colombo, Leandro Perino, Ernesto de Vito, Irma Esther Raba, Julio |
author2_role |
author author author author |
dc.subject.none.fl_str_mv |
Solid-Phase Mercury(Ii) X-Ray Fluorescence Spectrometry |
topic |
Solid-Phase Mercury(Ii) X-Ray Fluorescence Spectrometry |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.4 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
A novel and simple method was developed for the preconcentration and determination of mercury(II) from hydrochloric acid solutions through their adsorption on Aliquat 336 (tri-octylmethylammonium chloride)-activated carbon. The determinations were made directly on the solid by X-ray fluorescence spectrometry, which had the advantage of eliminating the step of elution of the mercury retained. This preconcentration system enabled the determination of Hg(II) in drinking water samples at µg l−1 levels. A 1700-fold enrichment factor was obtained. The described methodology showed excellent reproducibility, accuracy, and detection limits improvement by eliminating the step of elution of the analyte, replacing those methods based on cold vapor generation, reducing reagent consumption, and handling of samples. Fil: Aranda, Pedro Rodolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina Fil: Colombo, Leandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina Fil: Perino, Ernesto. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina Fil: de Vito, Irma Esther. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina Fil: Raba, Julio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina |
description |
A novel and simple method was developed for the preconcentration and determination of mercury(II) from hydrochloric acid solutions through their adsorption on Aliquat 336 (tri-octylmethylammonium chloride)-activated carbon. The determinations were made directly on the solid by X-ray fluorescence spectrometry, which had the advantage of eliminating the step of elution of the mercury retained. This preconcentration system enabled the determination of Hg(II) in drinking water samples at µg l−1 levels. A 1700-fold enrichment factor was obtained. The described methodology showed excellent reproducibility, accuracy, and detection limits improvement by eliminating the step of elution of the analyte, replacing those methods based on cold vapor generation, reducing reagent consumption, and handling of samples. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/5791 Aranda, Pedro Rodolfo; Colombo, Leandro; Perino, Ernesto; de Vito, Irma Esther; Raba, Julio; Solid-phase preconcentration and determination of mercury(II) using activated carbon in drinking water by X-ray fluorescence spectrometry; Wiley; X-ray Spectrometry; 42; 2; 1-2013; 100-104 0049-8246 |
url |
http://hdl.handle.net/11336/5791 |
identifier_str_mv |
Aranda, Pedro Rodolfo; Colombo, Leandro; Perino, Ernesto; de Vito, Irma Esther; Raba, Julio; Solid-phase preconcentration and determination of mercury(II) using activated carbon in drinking water by X-ray fluorescence spectrometry; Wiley; X-ray Spectrometry; 42; 2; 1-2013; 100-104 0049-8246 |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/http://onlinelibrary.wiley.com/doi/10.1002/xrs.2440/abstract info:eu-repo/semantics/altIdentifier/doi/ info:eu-repo/semantics/altIdentifier/doi/10.1002/xrs.2440 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Wiley |
publisher.none.fl_str_mv |
Wiley |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844613785611927552 |
score |
13.070432 |