Methodology to evaluate glare effects in corrected ammetropic subjects

Autores
de Paul Camacho, Anibal Gabriel; Colombo, Elisa Margarita; Comastri, Silvia Ana Elva; Aparicio, Juan A.; Menéndez, José Antonio; Issolio, Luis Alberto
Año de publicación
2013
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Light originated at a glare source and entering the eye, produces a veiling luminance that causes contrast decrease in retinal images and this effect could differ if the subject wears lenses or not. In this work the glare effects in subjects wearing lenses is studied inducing ammetropies in emmetropes. Contrast thresholds of sinusoidal patterns of 2 cpd and 0.5 cd/m2 are evaluated without and with glare, the glare source being steady, at 12o and producing 60 lx at the cornea. To exemplify the use of this methodology, 2 emmetropes under 8 different conditions are considered: naked eye; 3 control conditions (wearing neutral lenses) and 4 ammetropic conditions, inducing low (2 D) and medium (5 D) myopia and hyperopia with positive and negative contact lenses and correcting them with adequate ophthalmic lenses. The contrast threshold differences between the naked eye and the other 7 conditions are statistically not significant without glare and significant (up to more than 100%) with glare, independently of lens power and probably due to ectopic scattering and multiple reflections. The method proposed enables the determination of the glare effects if lenses are worn though a greater population is required to attain conclusive data.
La luz originada en una fuente deslumbrante que entra al ojo, produce una luminancia de velo que causa una disminución de contraste en las imágenes retinianas y este efecto podría diferir si el sujeto usa lentes o no. En este trabajo se estudian los efectos del deslumbramiento en sujetos que usan lentes induciendo ametropías en emétropes. Se evalúan contrastes umbrales de patrones sinusoidales de 2 cpd y 0.5 cd/m2 sin y con deslumbramiento, la fuente deslumbrante siendo estable, a 12º y produciendo 60 lx en la córnea. Para ejemplificar el uso de esta metodología, se consideran 2 emétropes en 8 condiciones diferentes: ojo desnudo; 3 condiciones de control (lentes neutras) y 4 condiciones ametrópicas, induciendo miopía e hipermetropía baja (±2 D) y media (±5 D) con lentes de contacto positivas y negativas y corrigiéndolas con adecuadas lentes oftálmicas. Las diferencias de contraste entre el ojo desnudo y las otras 7 condiciones son estadísticamente no significativas sin deslumbramiento y significativas (hasta más de 100%) con deslumbramiento, independientemente de la potencia de la lente y probablemente debido a scattering ectópico y reflexiones múltiples. El método propuesto permite determinar los efectos de deslumbramiento al usar lentes aunque, para tener datos contundentes, se requiere una mayor población
Fil: de Paul Camacho, Anibal Gabriel. Universidad Nacional de Tucuman. Facultad de Cs.exactas y Tecnologia. Departamento de Luminotecnia, Luz y Vision; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucuman. Instituto de Investigacion En Luz, Ambiente y Vision; Argentina
Fil: Colombo, Elisa Margarita. Universidad Nacional de Tucuman. Facultad de Cs.exactas y Tecnologia. Departamento de Luminotecnia, Luz y Vision; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucuman. Instituto de Investigacion En Luz, Ambiente y Vision; Argentina
Fil: Comastri, Silvia Ana Elva. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad de Buenos Aires. Facultad de Ingenieria. Departamento de Fisica; Argentina
Fil: Aparicio, Juan A.. Universidad de Valladolid. Facultad de Ciencias; España
Fil: Menéndez, José Antonio. Universidad de Valladolid. Facultad de Ciencias; España
Fil: Issolio, Luis Alberto. Universidad Nacional de Tucuman. Facultad de Cs.exactas y Tecnologia. Departamento de Luminotecnia, Luz y Vision; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucuman. Instituto de Investigacion En Luz, Ambiente y Vision; Argentina
Materia
NIGHT DRIVING
AMMETROPIES
OPHTHALMIC AND CONTACT LENSES
CONTRAST THRESHOLD
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/7318

id CONICETDig_f0805929dd18aa3821a7e285934d76f3
oai_identifier_str oai:ri.conicet.gov.ar:11336/7318
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Methodology to evaluate glare effects in corrected ammetropic subjectsMetodología para evaluar efectos del deslumbramiento en amétropes corregidosde Paul Camacho, Anibal GabrielColombo, Elisa MargaritaComastri, Silvia Ana ElvaAparicio, Juan A.Menéndez, José AntonioIssolio, Luis AlbertoNIGHT DRIVINGAMMETROPIESOPHTHALMIC AND CONTACT LENSESCONTRAST THRESHOLDhttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1Light originated at a glare source and entering the eye, produces a veiling luminance that causes contrast decrease in retinal images and this effect could differ if the subject wears lenses or not. In this work the glare effects in subjects wearing lenses is studied inducing ammetropies in emmetropes. Contrast thresholds of sinusoidal patterns of 2 cpd and 0.5 cd/m2 are evaluated without and with glare, the glare source being steady, at 12o and producing 60 lx at the cornea. To exemplify the use of this methodology, 2 emmetropes under 8 different conditions are considered: naked eye; 3 control conditions (wearing neutral lenses) and 4 ammetropic conditions, inducing low (2 D) and medium (5 D) myopia and hyperopia with positive and negative contact lenses and correcting them with adequate ophthalmic lenses. The contrast threshold differences between the naked eye and the other 7 conditions are statistically not significant without glare and significant (up to more than 100%) with glare, independently of lens power and probably due to ectopic scattering and multiple reflections. The method proposed enables the determination of the glare effects if lenses are worn though a greater population is required to attain conclusive data.La luz originada en una fuente deslumbrante que entra al ojo, produce una luminancia de velo que causa una disminución de contraste en las imágenes retinianas y este efecto podría diferir si el sujeto usa lentes o no. En este trabajo se estudian los efectos del deslumbramiento en sujetos que usan lentes induciendo ametropías en emétropes. Se evalúan contrastes umbrales de patrones sinusoidales de 2 cpd y 0.5 cd/m2 sin y con deslumbramiento, la fuente deslumbrante siendo estable, a 12º y produciendo 60 lx en la córnea. Para ejemplificar el uso de esta metodología, se consideran 2 emétropes en 8 condiciones diferentes: ojo desnudo; 3 condiciones de control (lentes neutras) y 4 condiciones ametrópicas, induciendo miopía e hipermetropía baja (±2 D) y media (±5 D) con lentes de contacto positivas y negativas y corrigiéndolas con adecuadas lentes oftálmicas. Las diferencias de contraste entre el ojo desnudo y las otras 7 condiciones son estadísticamente no significativas sin deslumbramiento y significativas (hasta más de 100%) con deslumbramiento, independientemente de la potencia de la lente y probablemente debido a scattering ectópico y reflexiones múltiples. El método propuesto permite determinar los efectos de deslumbramiento al usar lentes aunque, para tener datos contundentes, se requiere una mayor poblaciónFil: de Paul Camacho, Anibal Gabriel. Universidad Nacional de Tucuman. Facultad de Cs.exactas y Tecnologia. Departamento de Luminotecnia, Luz y Vision; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucuman. Instituto de Investigacion En Luz, Ambiente y Vision; ArgentinaFil: Colombo, Elisa Margarita. Universidad Nacional de Tucuman. Facultad de Cs.exactas y Tecnologia. Departamento de Luminotecnia, Luz y Vision; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucuman. Instituto de Investigacion En Luz, Ambiente y Vision; ArgentinaFil: Comastri, Silvia Ana Elva. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad de Buenos Aires. Facultad de Ingenieria. Departamento de Fisica; ArgentinaFil: Aparicio, Juan A.. Universidad de Valladolid. Facultad de Ciencias; EspañaFil: Menéndez, José Antonio. Universidad de Valladolid. Facultad de Ciencias; EspañaFil: Issolio, Luis Alberto. Universidad Nacional de Tucuman. Facultad de Cs.exactas y Tecnologia. Departamento de Luminotecnia, Luz y Vision; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucuman. Instituto de Investigacion En Luz, Ambiente y Vision; ArgentinaSociedad Española de Óptica2013-06info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/7318de Paul Camacho, Anibal Gabriel; Colombo, Elisa Margarita; Comastri, Silvia Ana Elva; Aparicio, Juan A.; Menéndez, José Antonio; et al.; Methodology to evaluate glare effects in corrected ammetropic subjects; Sociedad Española de Óptica; Óptica Pura y Aplicada; 46; 3; 6-2013; 285-2930030-3917enginfo:eu-repo/semantics/altIdentifier/url/http://www.sedoptica.es/Menu_Volumenes/opavols.php?volumen=46&numero=3info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:36:19Zoai:ri.conicet.gov.ar:11336/7318instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:36:19.867CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Methodology to evaluate glare effects in corrected ammetropic subjects
Metodología para evaluar efectos del deslumbramiento en amétropes corregidos
title Methodology to evaluate glare effects in corrected ammetropic subjects
spellingShingle Methodology to evaluate glare effects in corrected ammetropic subjects
de Paul Camacho, Anibal Gabriel
NIGHT DRIVING
AMMETROPIES
OPHTHALMIC AND CONTACT LENSES
CONTRAST THRESHOLD
title_short Methodology to evaluate glare effects in corrected ammetropic subjects
title_full Methodology to evaluate glare effects in corrected ammetropic subjects
title_fullStr Methodology to evaluate glare effects in corrected ammetropic subjects
title_full_unstemmed Methodology to evaluate glare effects in corrected ammetropic subjects
title_sort Methodology to evaluate glare effects in corrected ammetropic subjects
dc.creator.none.fl_str_mv de Paul Camacho, Anibal Gabriel
Colombo, Elisa Margarita
Comastri, Silvia Ana Elva
Aparicio, Juan A.
Menéndez, José Antonio
Issolio, Luis Alberto
author de Paul Camacho, Anibal Gabriel
author_facet de Paul Camacho, Anibal Gabriel
Colombo, Elisa Margarita
Comastri, Silvia Ana Elva
Aparicio, Juan A.
Menéndez, José Antonio
Issolio, Luis Alberto
author_role author
author2 Colombo, Elisa Margarita
Comastri, Silvia Ana Elva
Aparicio, Juan A.
Menéndez, José Antonio
Issolio, Luis Alberto
author2_role author
author
author
author
author
dc.subject.none.fl_str_mv NIGHT DRIVING
AMMETROPIES
OPHTHALMIC AND CONTACT LENSES
CONTRAST THRESHOLD
topic NIGHT DRIVING
AMMETROPIES
OPHTHALMIC AND CONTACT LENSES
CONTRAST THRESHOLD
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.3
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv Light originated at a glare source and entering the eye, produces a veiling luminance that causes contrast decrease in retinal images and this effect could differ if the subject wears lenses or not. In this work the glare effects in subjects wearing lenses is studied inducing ammetropies in emmetropes. Contrast thresholds of sinusoidal patterns of 2 cpd and 0.5 cd/m2 are evaluated without and with glare, the glare source being steady, at 12o and producing 60 lx at the cornea. To exemplify the use of this methodology, 2 emmetropes under 8 different conditions are considered: naked eye; 3 control conditions (wearing neutral lenses) and 4 ammetropic conditions, inducing low (2 D) and medium (5 D) myopia and hyperopia with positive and negative contact lenses and correcting them with adequate ophthalmic lenses. The contrast threshold differences between the naked eye and the other 7 conditions are statistically not significant without glare and significant (up to more than 100%) with glare, independently of lens power and probably due to ectopic scattering and multiple reflections. The method proposed enables the determination of the glare effects if lenses are worn though a greater population is required to attain conclusive data.
La luz originada en una fuente deslumbrante que entra al ojo, produce una luminancia de velo que causa una disminución de contraste en las imágenes retinianas y este efecto podría diferir si el sujeto usa lentes o no. En este trabajo se estudian los efectos del deslumbramiento en sujetos que usan lentes induciendo ametropías en emétropes. Se evalúan contrastes umbrales de patrones sinusoidales de 2 cpd y 0.5 cd/m2 sin y con deslumbramiento, la fuente deslumbrante siendo estable, a 12º y produciendo 60 lx en la córnea. Para ejemplificar el uso de esta metodología, se consideran 2 emétropes en 8 condiciones diferentes: ojo desnudo; 3 condiciones de control (lentes neutras) y 4 condiciones ametrópicas, induciendo miopía e hipermetropía baja (±2 D) y media (±5 D) con lentes de contacto positivas y negativas y corrigiéndolas con adecuadas lentes oftálmicas. Las diferencias de contraste entre el ojo desnudo y las otras 7 condiciones son estadísticamente no significativas sin deslumbramiento y significativas (hasta más de 100%) con deslumbramiento, independientemente de la potencia de la lente y probablemente debido a scattering ectópico y reflexiones múltiples. El método propuesto permite determinar los efectos de deslumbramiento al usar lentes aunque, para tener datos contundentes, se requiere una mayor población
Fil: de Paul Camacho, Anibal Gabriel. Universidad Nacional de Tucuman. Facultad de Cs.exactas y Tecnologia. Departamento de Luminotecnia, Luz y Vision; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucuman. Instituto de Investigacion En Luz, Ambiente y Vision; Argentina
Fil: Colombo, Elisa Margarita. Universidad Nacional de Tucuman. Facultad de Cs.exactas y Tecnologia. Departamento de Luminotecnia, Luz y Vision; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucuman. Instituto de Investigacion En Luz, Ambiente y Vision; Argentina
Fil: Comastri, Silvia Ana Elva. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad de Buenos Aires. Facultad de Ingenieria. Departamento de Fisica; Argentina
Fil: Aparicio, Juan A.. Universidad de Valladolid. Facultad de Ciencias; España
Fil: Menéndez, José Antonio. Universidad de Valladolid. Facultad de Ciencias; España
Fil: Issolio, Luis Alberto. Universidad Nacional de Tucuman. Facultad de Cs.exactas y Tecnologia. Departamento de Luminotecnia, Luz y Vision; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Tucuman. Instituto de Investigacion En Luz, Ambiente y Vision; Argentina
description Light originated at a glare source and entering the eye, produces a veiling luminance that causes contrast decrease in retinal images and this effect could differ if the subject wears lenses or not. In this work the glare effects in subjects wearing lenses is studied inducing ammetropies in emmetropes. Contrast thresholds of sinusoidal patterns of 2 cpd and 0.5 cd/m2 are evaluated without and with glare, the glare source being steady, at 12o and producing 60 lx at the cornea. To exemplify the use of this methodology, 2 emmetropes under 8 different conditions are considered: naked eye; 3 control conditions (wearing neutral lenses) and 4 ammetropic conditions, inducing low (2 D) and medium (5 D) myopia and hyperopia with positive and negative contact lenses and correcting them with adequate ophthalmic lenses. The contrast threshold differences between the naked eye and the other 7 conditions are statistically not significant without glare and significant (up to more than 100%) with glare, independently of lens power and probably due to ectopic scattering and multiple reflections. The method proposed enables the determination of the glare effects if lenses are worn though a greater population is required to attain conclusive data.
publishDate 2013
dc.date.none.fl_str_mv 2013-06
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/7318
de Paul Camacho, Anibal Gabriel; Colombo, Elisa Margarita; Comastri, Silvia Ana Elva; Aparicio, Juan A.; Menéndez, José Antonio; et al.; Methodology to evaluate glare effects in corrected ammetropic subjects; Sociedad Española de Óptica; Óptica Pura y Aplicada; 46; 3; 6-2013; 285-293
0030-3917
url http://hdl.handle.net/11336/7318
identifier_str_mv de Paul Camacho, Anibal Gabriel; Colombo, Elisa Margarita; Comastri, Silvia Ana Elva; Aparicio, Juan A.; Menéndez, José Antonio; et al.; Methodology to evaluate glare effects in corrected ammetropic subjects; Sociedad Española de Óptica; Óptica Pura y Aplicada; 46; 3; 6-2013; 285-293
0030-3917
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/http://www.sedoptica.es/Menu_Volumenes/opavols.php?volumen=46&numero=3
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Sociedad Española de Óptica
publisher.none.fl_str_mv Sociedad Española de Óptica
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844614383491088384
score 13.070432