Contamination by Larger Particles of Two Almost-Uniform Lattices: Analysis by Combined Light Scattering and Turbidimetry
- Autores
- González, Verónica Doris Guadalupe; Gugliotta, Luis Marcelino; Vega, Jorge Ruben; Meira, Gregorio Raul
- Año de publicación
- 2005
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- Multiangle dynamic light scattering (MDLS) and turbidimetry (T) were applied (both individually and combined) for determining the contamination by larger particles of two almost-uniform polystyrene (PS) latices. Latex 1 was synthesized in our laboratories, and it contained a main population diameter of 340 nm together with a small fraction of larger particles. This latex was used as the base material for producing an immunoassay kit. Latex 2 was obtained by a simple blend of two uniform PS standards. The proposed data treatment calculates the diameter and number fraction of the large particles contamination assuming that the PSDs are bimodal. The calculation involves minimizing the errors between the measurements and their theoretical predictions. When analyzed by combined MDLS–T, the contamination of Latex 1 involved number fraction 0.6% and particle diameter 865 nm. The T average diameter is a function of the measurement wavelength, and the highest deviations of this average to an increasing contamination by large particles were always observed at the higher wavelengths. The DLS average diameter is a function of the measurement angle, but in this case it is impossible to determine a priori the angle of observation that provides the largest deviation of this average diameter to an increasing contamination.
Fil: González, Verónica Doris Guadalupe. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina
Fil: Gugliotta, Luis Marcelino. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina
Fil: Vega, Jorge Ruben. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina
Fil: Meira, Gregorio Raul. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/26625
Ver los metadatos del registro completo
id |
CONICETDig_ee7dce02b5f2196d6a587599237cc4a1 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/26625 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Contamination by Larger Particles of Two Almost-Uniform Lattices: Analysis by Combined Light Scattering and TurbidimetryGonzález, Verónica Doris GuadalupeGugliotta, Luis MarcelinoVega, Jorge RubenMeira, Gregorio Raulhttps://purl.org/becyt/ford/2.4https://purl.org/becyt/ford/2Multiangle dynamic light scattering (MDLS) and turbidimetry (T) were applied (both individually and combined) for determining the contamination by larger particles of two almost-uniform polystyrene (PS) latices. Latex 1 was synthesized in our laboratories, and it contained a main population diameter of 340 nm together with a small fraction of larger particles. This latex was used as the base material for producing an immunoassay kit. Latex 2 was obtained by a simple blend of two uniform PS standards. The proposed data treatment calculates the diameter and number fraction of the large particles contamination assuming that the PSDs are bimodal. The calculation involves minimizing the errors between the measurements and their theoretical predictions. When analyzed by combined MDLS–T, the contamination of Latex 1 involved number fraction 0.6% and particle diameter 865 nm. The T average diameter is a function of the measurement wavelength, and the highest deviations of this average to an increasing contamination by large particles were always observed at the higher wavelengths. The DLS average diameter is a function of the measurement angle, but in this case it is impossible to determine a priori the angle of observation that provides the largest deviation of this average diameter to an increasing contamination.Fil: González, Verónica Doris Guadalupe. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; ArgentinaFil: Gugliotta, Luis Marcelino. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; ArgentinaFil: Vega, Jorge Ruben. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; ArgentinaFil: Meira, Gregorio Raul. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; ArgentinaElsevier2005-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/26625González, Verónica Doris Guadalupe; Gugliotta, Luis Marcelino; Vega, Jorge Ruben; Meira, Gregorio Raul; Contamination by Larger Particles of Two Almost-Uniform Lattices: Analysis by Combined Light Scattering and Turbidimetry; Elsevier; Journal of Colloid and Interface Science; 285; 2; 12-2005; 581-5890021-9797CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0021979704012032info:eu-repo/semantics/altIdentifier/doi/10.1016/j.jcis.2004.12.001info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T10:22:28Zoai:ri.conicet.gov.ar:11336/26625instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 10:22:28.932CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Contamination by Larger Particles of Two Almost-Uniform Lattices: Analysis by Combined Light Scattering and Turbidimetry |
title |
Contamination by Larger Particles of Two Almost-Uniform Lattices: Analysis by Combined Light Scattering and Turbidimetry |
spellingShingle |
Contamination by Larger Particles of Two Almost-Uniform Lattices: Analysis by Combined Light Scattering and Turbidimetry González, Verónica Doris Guadalupe |
title_short |
Contamination by Larger Particles of Two Almost-Uniform Lattices: Analysis by Combined Light Scattering and Turbidimetry |
title_full |
Contamination by Larger Particles of Two Almost-Uniform Lattices: Analysis by Combined Light Scattering and Turbidimetry |
title_fullStr |
Contamination by Larger Particles of Two Almost-Uniform Lattices: Analysis by Combined Light Scattering and Turbidimetry |
title_full_unstemmed |
Contamination by Larger Particles of Two Almost-Uniform Lattices: Analysis by Combined Light Scattering and Turbidimetry |
title_sort |
Contamination by Larger Particles of Two Almost-Uniform Lattices: Analysis by Combined Light Scattering and Turbidimetry |
dc.creator.none.fl_str_mv |
González, Verónica Doris Guadalupe Gugliotta, Luis Marcelino Vega, Jorge Ruben Meira, Gregorio Raul |
author |
González, Verónica Doris Guadalupe |
author_facet |
González, Verónica Doris Guadalupe Gugliotta, Luis Marcelino Vega, Jorge Ruben Meira, Gregorio Raul |
author_role |
author |
author2 |
Gugliotta, Luis Marcelino Vega, Jorge Ruben Meira, Gregorio Raul |
author2_role |
author author author |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/2.4 https://purl.org/becyt/ford/2 |
dc.description.none.fl_txt_mv |
Multiangle dynamic light scattering (MDLS) and turbidimetry (T) were applied (both individually and combined) for determining the contamination by larger particles of two almost-uniform polystyrene (PS) latices. Latex 1 was synthesized in our laboratories, and it contained a main population diameter of 340 nm together with a small fraction of larger particles. This latex was used as the base material for producing an immunoassay kit. Latex 2 was obtained by a simple blend of two uniform PS standards. The proposed data treatment calculates the diameter and number fraction of the large particles contamination assuming that the PSDs are bimodal. The calculation involves minimizing the errors between the measurements and their theoretical predictions. When analyzed by combined MDLS–T, the contamination of Latex 1 involved number fraction 0.6% and particle diameter 865 nm. The T average diameter is a function of the measurement wavelength, and the highest deviations of this average to an increasing contamination by large particles were always observed at the higher wavelengths. The DLS average diameter is a function of the measurement angle, but in this case it is impossible to determine a priori the angle of observation that provides the largest deviation of this average diameter to an increasing contamination. Fil: González, Verónica Doris Guadalupe. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina Fil: Gugliotta, Luis Marcelino. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina Fil: Vega, Jorge Ruben. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina Fil: Meira, Gregorio Raul. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Desarrollo Tecnológico para la Industria Química. Universidad Nacional del Litoral. Instituto de Desarrollo Tecnológico para la Industria Química; Argentina |
description |
Multiangle dynamic light scattering (MDLS) and turbidimetry (T) were applied (both individually and combined) for determining the contamination by larger particles of two almost-uniform polystyrene (PS) latices. Latex 1 was synthesized in our laboratories, and it contained a main population diameter of 340 nm together with a small fraction of larger particles. This latex was used as the base material for producing an immunoassay kit. Latex 2 was obtained by a simple blend of two uniform PS standards. The proposed data treatment calculates the diameter and number fraction of the large particles contamination assuming that the PSDs are bimodal. The calculation involves minimizing the errors between the measurements and their theoretical predictions. When analyzed by combined MDLS–T, the contamination of Latex 1 involved number fraction 0.6% and particle diameter 865 nm. The T average diameter is a function of the measurement wavelength, and the highest deviations of this average to an increasing contamination by large particles were always observed at the higher wavelengths. The DLS average diameter is a function of the measurement angle, but in this case it is impossible to determine a priori the angle of observation that provides the largest deviation of this average diameter to an increasing contamination. |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005-12 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/26625 González, Verónica Doris Guadalupe; Gugliotta, Luis Marcelino; Vega, Jorge Ruben; Meira, Gregorio Raul; Contamination by Larger Particles of Two Almost-Uniform Lattices: Analysis by Combined Light Scattering and Turbidimetry; Elsevier; Journal of Colloid and Interface Science; 285; 2; 12-2005; 581-589 0021-9797 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/26625 |
identifier_str_mv |
González, Verónica Doris Guadalupe; Gugliotta, Luis Marcelino; Vega, Jorge Ruben; Meira, Gregorio Raul; Contamination by Larger Particles of Two Almost-Uniform Lattices: Analysis by Combined Light Scattering and Turbidimetry; Elsevier; Journal of Colloid and Interface Science; 285; 2; 12-2005; 581-589 0021-9797 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0021979704012032 info:eu-repo/semantics/altIdentifier/doi/10.1016/j.jcis.2004.12.001 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1844614216312422400 |
score |
13.070432 |