Therapeutic monitoring of pediatric transplant patients with conversion to generic tacrolimus

Autores
Riva, Natalia; Caceres Guido, Paulo Arturo; Licciardone, Nieves; Imventarza, Oscar; Monteverde, Marta; Staciuk, Raquel; Charroqui, Alberto; Schaiquevich, Paula Susana
Año de publicación
2017
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Objective: Therapeutic monitoring during interchange of tacrolimus commercial formulations is essential to ensure similar exposure in transplant patients. However, there are limited data in the pediatric transplant population. This study aims to evaluate exposure, safety and efficacy in maintenance pediatric transplant patients under generic tacrolimus substitution. Method: Pediatric patients who underwent interchange of tacrolimus formulations were detected by the Service of Pharmacy and included in this study. Tacrolimus trough levels (C0), laboratory parameters and clinical characteristics were recorded before and after the switch. Statistical analysis was performed using Wilcoxon matched pair t-test. Results: In total, 10 patients with kidney, liver, heart and hematopoietic stem cell transplantation received the innovator and switched to the generic product. The median (range) of the C0 normalized by the dose before and after switch was 74.8 [(ng/ml)/(mg/kg)] (13.8-518.4) and 65.1 [(ng/ml)/(mg/kg)] (13.5-723.5), respectively (p>0.05). Tacrolimus dose was 0.070(mg/kg) (0.024-0.461) and 0.069(mg/kg) (0.017-0.571) for the innovator and generic formulation, respectively, with no difference when comparing both values (p>0.05). Laboratory parameters did not change after conversion (p>0.05). Adverse events, acute rejection, death and graft loss were not observed. Conclusion: In our study population, no significant differences in terms of laboratory parameters, drug exposure and dose were observed. We emphasize the need of close monitoring to ensure a safe interchange, especially in vulnerable populations such as the pediatric.
Objetivo: La monitorización terapéutica durante el intercambio de marcas comerciales de inmunosupresores es esencial para mantener una similar exposición al fármaco en pacientes trasplantados. Sin embargo, la información disponible en trasplante pediátrico es limitada. El objetivo del trabajo fue evaluar la exposición, seguridad y eficacia en pacientes pediátricos trasplantados en etapa de mantenimiento, sujetos a intercambio entre el producto innovador y el genérico de tacrolimus. Método: El Área de Farmacia del hospital detectó aquellos pacientes sujetos a intercambio de formulaciones según la disponibilidad de medicamentos. Se obtuvieron las concentraciones de tacrolimus en el valle (C0), parámetros de laboratorio y características clínicas antes y después del intercambio. El análisis estadístico se realizó mediante el test de muestras pareadas de Wilcoxon. Resultados: Se incluyeron 10 pacientes con trasplante renal, hepático, cardíaco y de células hematopoyéticas. La mediana (rango) del C0 normalizado por la dosis pre y post intercambio fue 74,8[(ng/ml)/(mg/kg)](13,8-518,4) y 65,1[(ng/ml)/(mg/kg)] (13,5-723,5), respectivamente (p>0,05). La dosis de tacrolimus fue 0,070(mg/kg) (0,024-0,461) y 0,069(mg/kg) (0,017-0,571) para el innovador y el genérico, respectivamente (p>0,05). Los parámetros de laboratorio de funcionalidad renal y hepática no cambiaron con la conversión de marcas (p>0,05). No se observaron eventos adversos, rechazo agudo, muerte o pérdida del injerto durante el periodo analizado.
Fil: Riva, Natalia. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Caceres Guido, Paulo Arturo. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Licciardone, Nieves. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Imventarza, Oscar. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Monteverde, Marta. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Staciuk, Raquel. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Charroqui, Alberto. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Schaiquevich, Paula Susana. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Materia
GENERIC DRUGS
ORGAN TRANSPLANTATION
PEDIATRICS
TACROLIMUS
THERAPEUTIC DRUG MONITORING
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/77403

id CONICETDig_eab4970540bb43d84fcd3b393d19a185
oai_identifier_str oai:ri.conicet.gov.ar:11336/77403
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Therapeutic monitoring of pediatric transplant patients with conversion to generic tacrolimusMonitorización terapéutico del tacrolimus en pacientes pediátricos trasplantados sujetos a conversión de marcas comercialesRiva, NataliaCaceres Guido, Paulo ArturoLicciardone, NievesImventarza, OscarMonteverde, MartaStaciuk, RaquelCharroqui, AlbertoSchaiquevich, Paula SusanaGENERIC DRUGSORGAN TRANSPLANTATIONPEDIATRICSTACROLIMUSTHERAPEUTIC DRUG MONITORINGhttps://purl.org/becyt/ford/3.2https://purl.org/becyt/ford/3Objective: Therapeutic monitoring during interchange of tacrolimus commercial formulations is essential to ensure similar exposure in transplant patients. However, there are limited data in the pediatric transplant population. This study aims to evaluate exposure, safety and efficacy in maintenance pediatric transplant patients under generic tacrolimus substitution. Method: Pediatric patients who underwent interchange of tacrolimus formulations were detected by the Service of Pharmacy and included in this study. Tacrolimus trough levels (C0), laboratory parameters and clinical characteristics were recorded before and after the switch. Statistical analysis was performed using Wilcoxon matched pair t-test. Results: In total, 10 patients with kidney, liver, heart and hematopoietic stem cell transplantation received the innovator and switched to the generic product. The median (range) of the C0 normalized by the dose before and after switch was 74.8 [(ng/ml)/(mg/kg)] (13.8-518.4) and 65.1 [(ng/ml)/(mg/kg)] (13.5-723.5), respectively (p>0.05). Tacrolimus dose was 0.070(mg/kg) (0.024-0.461) and 0.069(mg/kg) (0.017-0.571) for the innovator and generic formulation, respectively, with no difference when comparing both values (p>0.05). Laboratory parameters did not change after conversion (p>0.05). Adverse events, acute rejection, death and graft loss were not observed. Conclusion: In our study population, no significant differences in terms of laboratory parameters, drug exposure and dose were observed. We emphasize the need of close monitoring to ensure a safe interchange, especially in vulnerable populations such as the pediatric.Objetivo: La monitorización terapéutica durante el intercambio de marcas comerciales de inmunosupresores es esencial para mantener una similar exposición al fármaco en pacientes trasplantados. Sin embargo, la información disponible en trasplante pediátrico es limitada. El objetivo del trabajo fue evaluar la exposición, seguridad y eficacia en pacientes pediátricos trasplantados en etapa de mantenimiento, sujetos a intercambio entre el producto innovador y el genérico de tacrolimus. Método: El Área de Farmacia del hospital detectó aquellos pacientes sujetos a intercambio de formulaciones según la disponibilidad de medicamentos. Se obtuvieron las concentraciones de tacrolimus en el valle (C0), parámetros de laboratorio y características clínicas antes y después del intercambio. El análisis estadístico se realizó mediante el test de muestras pareadas de Wilcoxon. Resultados: Se incluyeron 10 pacientes con trasplante renal, hepático, cardíaco y de células hematopoyéticas. La mediana (rango) del C0 normalizado por la dosis pre y post intercambio fue 74,8[(ng/ml)/(mg/kg)](13,8-518,4) y 65,1[(ng/ml)/(mg/kg)] (13,5-723,5), respectivamente (p>0,05). La dosis de tacrolimus fue 0,070(mg/kg) (0,024-0,461) y 0,069(mg/kg) (0,017-0,571) para el innovador y el genérico, respectivamente (p>0,05). Los parámetros de laboratorio de funcionalidad renal y hepática no cambiaron con la conversión de marcas (p>0,05). No se observaron eventos adversos, rechazo agudo, muerte o pérdida del injerto durante el periodo analizado.Fil: Riva, Natalia. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; ArgentinaFil: Caceres Guido, Paulo Arturo. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; ArgentinaFil: Licciardone, Nieves. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; ArgentinaFil: Imventarza, Oscar. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; ArgentinaFil: Monteverde, Marta. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; ArgentinaFil: Staciuk, Raquel. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; ArgentinaFil: Charroqui, Alberto. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; ArgentinaFil: Schaiquevich, Paula Susana. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; ArgentinaSociedad Espanola de Farmacia Hospitalaria2017-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/77403Riva, Natalia; Caceres Guido, Paulo Arturo; Licciardone, Nieves; Imventarza, Oscar; Monteverde, Marta; et al.; Therapeutic monitoring of pediatric transplant patients with conversion to generic tacrolimus; Sociedad Espanola de Farmacia Hospitalaria; Farmacia Hospitalaria; 41; 2; 3-2017; 150-1681130-63432171-8695CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://www.aulamedica.es/fh/pdf/10534.pdfinfo:eu-repo/semantics/altIdentifier/doi/10.7399/fh.2017.41.2.10534info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:52:50Zoai:ri.conicet.gov.ar:11336/77403instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:52:51.084CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Therapeutic monitoring of pediatric transplant patients with conversion to generic tacrolimus
Monitorización terapéutico del tacrolimus en pacientes pediátricos trasplantados sujetos a conversión de marcas comerciales
title Therapeutic monitoring of pediatric transplant patients with conversion to generic tacrolimus
spellingShingle Therapeutic monitoring of pediatric transplant patients with conversion to generic tacrolimus
Riva, Natalia
GENERIC DRUGS
ORGAN TRANSPLANTATION
PEDIATRICS
TACROLIMUS
THERAPEUTIC DRUG MONITORING
title_short Therapeutic monitoring of pediatric transplant patients with conversion to generic tacrolimus
title_full Therapeutic monitoring of pediatric transplant patients with conversion to generic tacrolimus
title_fullStr Therapeutic monitoring of pediatric transplant patients with conversion to generic tacrolimus
title_full_unstemmed Therapeutic monitoring of pediatric transplant patients with conversion to generic tacrolimus
title_sort Therapeutic monitoring of pediatric transplant patients with conversion to generic tacrolimus
dc.creator.none.fl_str_mv Riva, Natalia
Caceres Guido, Paulo Arturo
Licciardone, Nieves
Imventarza, Oscar
Monteverde, Marta
Staciuk, Raquel
Charroqui, Alberto
Schaiquevich, Paula Susana
author Riva, Natalia
author_facet Riva, Natalia
Caceres Guido, Paulo Arturo
Licciardone, Nieves
Imventarza, Oscar
Monteverde, Marta
Staciuk, Raquel
Charroqui, Alberto
Schaiquevich, Paula Susana
author_role author
author2 Caceres Guido, Paulo Arturo
Licciardone, Nieves
Imventarza, Oscar
Monteverde, Marta
Staciuk, Raquel
Charroqui, Alberto
Schaiquevich, Paula Susana
author2_role author
author
author
author
author
author
author
dc.subject.none.fl_str_mv GENERIC DRUGS
ORGAN TRANSPLANTATION
PEDIATRICS
TACROLIMUS
THERAPEUTIC DRUG MONITORING
topic GENERIC DRUGS
ORGAN TRANSPLANTATION
PEDIATRICS
TACROLIMUS
THERAPEUTIC DRUG MONITORING
purl_subject.fl_str_mv https://purl.org/becyt/ford/3.2
https://purl.org/becyt/ford/3
dc.description.none.fl_txt_mv Objective: Therapeutic monitoring during interchange of tacrolimus commercial formulations is essential to ensure similar exposure in transplant patients. However, there are limited data in the pediatric transplant population. This study aims to evaluate exposure, safety and efficacy in maintenance pediatric transplant patients under generic tacrolimus substitution. Method: Pediatric patients who underwent interchange of tacrolimus formulations were detected by the Service of Pharmacy and included in this study. Tacrolimus trough levels (C0), laboratory parameters and clinical characteristics were recorded before and after the switch. Statistical analysis was performed using Wilcoxon matched pair t-test. Results: In total, 10 patients with kidney, liver, heart and hematopoietic stem cell transplantation received the innovator and switched to the generic product. The median (range) of the C0 normalized by the dose before and after switch was 74.8 [(ng/ml)/(mg/kg)] (13.8-518.4) and 65.1 [(ng/ml)/(mg/kg)] (13.5-723.5), respectively (p>0.05). Tacrolimus dose was 0.070(mg/kg) (0.024-0.461) and 0.069(mg/kg) (0.017-0.571) for the innovator and generic formulation, respectively, with no difference when comparing both values (p>0.05). Laboratory parameters did not change after conversion (p>0.05). Adverse events, acute rejection, death and graft loss were not observed. Conclusion: In our study population, no significant differences in terms of laboratory parameters, drug exposure and dose were observed. We emphasize the need of close monitoring to ensure a safe interchange, especially in vulnerable populations such as the pediatric.
Objetivo: La monitorización terapéutica durante el intercambio de marcas comerciales de inmunosupresores es esencial para mantener una similar exposición al fármaco en pacientes trasplantados. Sin embargo, la información disponible en trasplante pediátrico es limitada. El objetivo del trabajo fue evaluar la exposición, seguridad y eficacia en pacientes pediátricos trasplantados en etapa de mantenimiento, sujetos a intercambio entre el producto innovador y el genérico de tacrolimus. Método: El Área de Farmacia del hospital detectó aquellos pacientes sujetos a intercambio de formulaciones según la disponibilidad de medicamentos. Se obtuvieron las concentraciones de tacrolimus en el valle (C0), parámetros de laboratorio y características clínicas antes y después del intercambio. El análisis estadístico se realizó mediante el test de muestras pareadas de Wilcoxon. Resultados: Se incluyeron 10 pacientes con trasplante renal, hepático, cardíaco y de células hematopoyéticas. La mediana (rango) del C0 normalizado por la dosis pre y post intercambio fue 74,8[(ng/ml)/(mg/kg)](13,8-518,4) y 65,1[(ng/ml)/(mg/kg)] (13,5-723,5), respectivamente (p>0,05). La dosis de tacrolimus fue 0,070(mg/kg) (0,024-0,461) y 0,069(mg/kg) (0,017-0,571) para el innovador y el genérico, respectivamente (p>0,05). Los parámetros de laboratorio de funcionalidad renal y hepática no cambiaron con la conversión de marcas (p>0,05). No se observaron eventos adversos, rechazo agudo, muerte o pérdida del injerto durante el periodo analizado.
Fil: Riva, Natalia. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Caceres Guido, Paulo Arturo. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Licciardone, Nieves. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Imventarza, Oscar. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Monteverde, Marta. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Staciuk, Raquel. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Charroqui, Alberto. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
Fil: Schaiquevich, Paula Susana. Gobierno de la Ciudad de Buenos Aires. Hospital de Pediatría "Juan P. Garrahan"; Argentina
description Objective: Therapeutic monitoring during interchange of tacrolimus commercial formulations is essential to ensure similar exposure in transplant patients. However, there are limited data in the pediatric transplant population. This study aims to evaluate exposure, safety and efficacy in maintenance pediatric transplant patients under generic tacrolimus substitution. Method: Pediatric patients who underwent interchange of tacrolimus formulations were detected by the Service of Pharmacy and included in this study. Tacrolimus trough levels (C0), laboratory parameters and clinical characteristics were recorded before and after the switch. Statistical analysis was performed using Wilcoxon matched pair t-test. Results: In total, 10 patients with kidney, liver, heart and hematopoietic stem cell transplantation received the innovator and switched to the generic product. The median (range) of the C0 normalized by the dose before and after switch was 74.8 [(ng/ml)/(mg/kg)] (13.8-518.4) and 65.1 [(ng/ml)/(mg/kg)] (13.5-723.5), respectively (p>0.05). Tacrolimus dose was 0.070(mg/kg) (0.024-0.461) and 0.069(mg/kg) (0.017-0.571) for the innovator and generic formulation, respectively, with no difference when comparing both values (p>0.05). Laboratory parameters did not change after conversion (p>0.05). Adverse events, acute rejection, death and graft loss were not observed. Conclusion: In our study population, no significant differences in terms of laboratory parameters, drug exposure and dose were observed. We emphasize the need of close monitoring to ensure a safe interchange, especially in vulnerable populations such as the pediatric.
publishDate 2017
dc.date.none.fl_str_mv 2017-03
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/77403
Riva, Natalia; Caceres Guido, Paulo Arturo; Licciardone, Nieves; Imventarza, Oscar; Monteverde, Marta; et al.; Therapeutic monitoring of pediatric transplant patients with conversion to generic tacrolimus; Sociedad Espanola de Farmacia Hospitalaria; Farmacia Hospitalaria; 41; 2; 3-2017; 150-168
1130-6343
2171-8695
CONICET Digital
CONICET
url http://hdl.handle.net/11336/77403
identifier_str_mv Riva, Natalia; Caceres Guido, Paulo Arturo; Licciardone, Nieves; Imventarza, Oscar; Monteverde, Marta; et al.; Therapeutic monitoring of pediatric transplant patients with conversion to generic tacrolimus; Sociedad Espanola de Farmacia Hospitalaria; Farmacia Hospitalaria; 41; 2; 3-2017; 150-168
1130-6343
2171-8695
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/http://www.aulamedica.es/fh/pdf/10534.pdf
info:eu-repo/semantics/altIdentifier/doi/10.7399/fh.2017.41.2.10534
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
application/pdf
dc.publisher.none.fl_str_mv Sociedad Espanola de Farmacia Hospitalaria
publisher.none.fl_str_mv Sociedad Espanola de Farmacia Hospitalaria
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1842269186355625984
score 13.13397