Accuracy of the SD BIOLINE Dengue Duo for rapid point-of-care diagnosis of dengue

Autores
Kikuti, Mariana; Cruz, Jaqueline S.; Rodrigues, Moreno S.; Tavares, Aline S.; Paploski, Igor A. D.; Silva, Monaise M. O.; Santana, Perla M.; Tauro, Laura Beatriz; Silva, Greice A. O. F.; Campos, Gúbio S.; Araújo, Josélio M. G.; Kitron, Uriel D.; Reis, Mitermayer G.; Ribeiro, Guilherme S.
Año de publicación
2019
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Background Rapid diagnosis tests (RDTs) are easy to carry out, provide fast results, and could potentially guide medical treatment decisions. We investigated the performance of a commercially available RDT, which simultaneously detects the non-structural 1 (NS1) dengue virus (DENV) antigen, and IgM and IgG DENV antibodies, using representative serum samples from individuals in a dengue endemic area in Salvador, Brazil. Methodology/Principal findings We evaluated the accuracy of the SD BIOLINE Dengue Duo RDT (Abbott, Santa Clara, USA; former Alere Inc, Waltham, USA) in a random collection of sera. Samples included acute-phase sera from 246 laboratory-confirmed dengue cases and 108 non-dengue febrile patients enrolled in a surveillance study for dengue detection, 73 healthy controls living in the same surveillance community, and 73 blood donors. RDT accuracy was blindly assessed based on the combined results for the NS1 and the IgM test components. The RDT sensitivity was 46.8% (38.6% for the NS1 component and 13.8% for the IgM component). Sensitivity was greater for samples obtained from patients with secondary DENV infections (49.8%) compared to primary infections (31.1%) (P: 0.02) and was also influenced by the result in the confirmatory dengue diagnostic test, ranging from 39.7% for samples of cases confirmed by IgM-ELISA seroconversion between paired samples to 90.4% for samples of cases confirmed by a positive NS1-ELISA. The RDT specificity was 94.4% for non-dengue febrile patients, 87.7% for the community healthy controls, and 95.9% for the blood donors. Conclusions/Significance The SD BIOLINE Dengue Duo RDT showed good specificities, but low sensitivity, suggesting that it may be more useful to rule in than to rule out a dengue diagnosis in dengue endemic regions.
Fil: Kikuti, Mariana. Fundación Oswaldo Cruz; Brasil. Universidade Federal da Bahia; Brasil
Fil: Cruz, Jaqueline S.. Fundación Oswaldo Cruz; Brasil
Fil: Rodrigues, Moreno S.. Fundación Oswaldo Cruz; Brasil
Fil: Tavares, Aline S.. Fundación Oswaldo Cruz; Brasil
Fil: Paploski, Igor A. D.. Universidade Federal da Bahia; Brasil. University of Minnesota; Estados Unidos
Fil: Silva, Monaise M. O.. Fundación Oswaldo Cruz; Brasil
Fil: Santana, Perla M.. Fundación Oswaldo Cruz; Brasil
Fil: Tauro, Laura Beatriz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Nordeste. Instituto de Biología Subtropical. Instituto de Biología Subtropical - Nodo Puerto Iguazú | Universidad Nacional de Misiones. Instituto de Biología Subtropical. Instituto de Biología Subtropical - Nodo Puerto Iguazú; Argentina. Ministerio de Salud. Instituto Nacional de Medicina Tropical; Argentina
Fil: Silva, Greice A. O. F.. Fundación Oswaldo Cruz; Brasil
Fil: Campos, Gúbio S.. Universidade Federal da Bahia; Brasil
Fil: Araújo, Josélio M. G.. Universidade Federal do Rio Grande do Norte; Brasil
Fil: Kitron, Uriel D.. University of Emory; Estados Unidos
Fil: Reis, Mitermayer G.. Fundación Oswaldo Cruz; Brasil. Universidade Federal da Bahia; Brasil. University of Yale; Estados Unidos
Fil: Ribeiro, Guilherme S.. Universidade Federal da Bahia; Brasil. Fundación Oswaldo Cruz; Brasil
Materia
ARBOVIRUS
DENGUE VIRUS
DIAGNOSTIC
EPIDEMIOLOGY
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/104375

id CONICETDig_e9103c3da00a04121fc3d74abd890cc8
oai_identifier_str oai:ri.conicet.gov.ar:11336/104375
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Accuracy of the SD BIOLINE Dengue Duo for rapid point-of-care diagnosis of dengueKikuti, MarianaCruz, Jaqueline S.Rodrigues, Moreno S.Tavares, Aline S.Paploski, Igor A. D.Silva, Monaise M. O.Santana, Perla M.Tauro, Laura BeatrizSilva, Greice A. O. F.Campos, Gúbio S.Araújo, Josélio M. G.Kitron, Uriel D.Reis, Mitermayer G.Ribeiro, Guilherme S.ARBOVIRUSDENGUE VIRUSDIAGNOSTICEPIDEMIOLOGYhttps://purl.org/becyt/ford/1.6https://purl.org/becyt/ford/1Background Rapid diagnosis tests (RDTs) are easy to carry out, provide fast results, and could potentially guide medical treatment decisions. We investigated the performance of a commercially available RDT, which simultaneously detects the non-structural 1 (NS1) dengue virus (DENV) antigen, and IgM and IgG DENV antibodies, using representative serum samples from individuals in a dengue endemic area in Salvador, Brazil. Methodology/Principal findings We evaluated the accuracy of the SD BIOLINE Dengue Duo RDT (Abbott, Santa Clara, USA; former Alere Inc, Waltham, USA) in a random collection of sera. Samples included acute-phase sera from 246 laboratory-confirmed dengue cases and 108 non-dengue febrile patients enrolled in a surveillance study for dengue detection, 73 healthy controls living in the same surveillance community, and 73 blood donors. RDT accuracy was blindly assessed based on the combined results for the NS1 and the IgM test components. The RDT sensitivity was 46.8% (38.6% for the NS1 component and 13.8% for the IgM component). Sensitivity was greater for samples obtained from patients with secondary DENV infections (49.8%) compared to primary infections (31.1%) (P: 0.02) and was also influenced by the result in the confirmatory dengue diagnostic test, ranging from 39.7% for samples of cases confirmed by IgM-ELISA seroconversion between paired samples to 90.4% for samples of cases confirmed by a positive NS1-ELISA. The RDT specificity was 94.4% for non-dengue febrile patients, 87.7% for the community healthy controls, and 95.9% for the blood donors. Conclusions/Significance The SD BIOLINE Dengue Duo RDT showed good specificities, but low sensitivity, suggesting that it may be more useful to rule in than to rule out a dengue diagnosis in dengue endemic regions.Fil: Kikuti, Mariana. Fundación Oswaldo Cruz; Brasil. Universidade Federal da Bahia; BrasilFil: Cruz, Jaqueline S.. Fundación Oswaldo Cruz; BrasilFil: Rodrigues, Moreno S.. Fundación Oswaldo Cruz; BrasilFil: Tavares, Aline S.. Fundación Oswaldo Cruz; BrasilFil: Paploski, Igor A. D.. Universidade Federal da Bahia; Brasil. University of Minnesota; Estados UnidosFil: Silva, Monaise M. O.. Fundación Oswaldo Cruz; BrasilFil: Santana, Perla M.. Fundación Oswaldo Cruz; BrasilFil: Tauro, Laura Beatriz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Nordeste. Instituto de Biología Subtropical. Instituto de Biología Subtropical - Nodo Puerto Iguazú | Universidad Nacional de Misiones. Instituto de Biología Subtropical. Instituto de Biología Subtropical - Nodo Puerto Iguazú; Argentina. Ministerio de Salud. Instituto Nacional de Medicina Tropical; ArgentinaFil: Silva, Greice A. O. F.. Fundación Oswaldo Cruz; BrasilFil: Campos, Gúbio S.. Universidade Federal da Bahia; BrasilFil: Araújo, Josélio M. G.. Universidade Federal do Rio Grande do Norte; BrasilFil: Kitron, Uriel D.. University of Emory; Estados UnidosFil: Reis, Mitermayer G.. Fundación Oswaldo Cruz; Brasil. Universidade Federal da Bahia; Brasil. University of Yale; Estados UnidosFil: Ribeiro, Guilherme S.. Universidade Federal da Bahia; Brasil. Fundación Oswaldo Cruz; BrasilPublic Library of Science2019-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/104375Kikuti, Mariana; Cruz, Jaqueline S.; Rodrigues, Moreno S.; Tavares, Aline S.; Paploski, Igor A. D.; et al.; Accuracy of the SD BIOLINE Dengue Duo for rapid point-of-care diagnosis of dengue; Public Library of Science; Plos One; 14; 3; 3-2019; 1-151932-6203CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.1371/journal.pone.0213301info:eu-repo/semantics/altIdentifier/url/https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0213301info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:52:25Zoai:ri.conicet.gov.ar:11336/104375instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:52:25.339CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Accuracy of the SD BIOLINE Dengue Duo for rapid point-of-care diagnosis of dengue
title Accuracy of the SD BIOLINE Dengue Duo for rapid point-of-care diagnosis of dengue
spellingShingle Accuracy of the SD BIOLINE Dengue Duo for rapid point-of-care diagnosis of dengue
Kikuti, Mariana
ARBOVIRUS
DENGUE VIRUS
DIAGNOSTIC
EPIDEMIOLOGY
title_short Accuracy of the SD BIOLINE Dengue Duo for rapid point-of-care diagnosis of dengue
title_full Accuracy of the SD BIOLINE Dengue Duo for rapid point-of-care diagnosis of dengue
title_fullStr Accuracy of the SD BIOLINE Dengue Duo for rapid point-of-care diagnosis of dengue
title_full_unstemmed Accuracy of the SD BIOLINE Dengue Duo for rapid point-of-care diagnosis of dengue
title_sort Accuracy of the SD BIOLINE Dengue Duo for rapid point-of-care diagnosis of dengue
dc.creator.none.fl_str_mv Kikuti, Mariana
Cruz, Jaqueline S.
Rodrigues, Moreno S.
Tavares, Aline S.
Paploski, Igor A. D.
Silva, Monaise M. O.
Santana, Perla M.
Tauro, Laura Beatriz
Silva, Greice A. O. F.
Campos, Gúbio S.
Araújo, Josélio M. G.
Kitron, Uriel D.
Reis, Mitermayer G.
Ribeiro, Guilherme S.
author Kikuti, Mariana
author_facet Kikuti, Mariana
Cruz, Jaqueline S.
Rodrigues, Moreno S.
Tavares, Aline S.
Paploski, Igor A. D.
Silva, Monaise M. O.
Santana, Perla M.
Tauro, Laura Beatriz
Silva, Greice A. O. F.
Campos, Gúbio S.
Araújo, Josélio M. G.
Kitron, Uriel D.
Reis, Mitermayer G.
Ribeiro, Guilherme S.
author_role author
author2 Cruz, Jaqueline S.
Rodrigues, Moreno S.
Tavares, Aline S.
Paploski, Igor A. D.
Silva, Monaise M. O.
Santana, Perla M.
Tauro, Laura Beatriz
Silva, Greice A. O. F.
Campos, Gúbio S.
Araújo, Josélio M. G.
Kitron, Uriel D.
Reis, Mitermayer G.
Ribeiro, Guilherme S.
author2_role author
author
author
author
author
author
author
author
author
author
author
author
author
dc.subject.none.fl_str_mv ARBOVIRUS
DENGUE VIRUS
DIAGNOSTIC
EPIDEMIOLOGY
topic ARBOVIRUS
DENGUE VIRUS
DIAGNOSTIC
EPIDEMIOLOGY
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.6
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv Background Rapid diagnosis tests (RDTs) are easy to carry out, provide fast results, and could potentially guide medical treatment decisions. We investigated the performance of a commercially available RDT, which simultaneously detects the non-structural 1 (NS1) dengue virus (DENV) antigen, and IgM and IgG DENV antibodies, using representative serum samples from individuals in a dengue endemic area in Salvador, Brazil. Methodology/Principal findings We evaluated the accuracy of the SD BIOLINE Dengue Duo RDT (Abbott, Santa Clara, USA; former Alere Inc, Waltham, USA) in a random collection of sera. Samples included acute-phase sera from 246 laboratory-confirmed dengue cases and 108 non-dengue febrile patients enrolled in a surveillance study for dengue detection, 73 healthy controls living in the same surveillance community, and 73 blood donors. RDT accuracy was blindly assessed based on the combined results for the NS1 and the IgM test components. The RDT sensitivity was 46.8% (38.6% for the NS1 component and 13.8% for the IgM component). Sensitivity was greater for samples obtained from patients with secondary DENV infections (49.8%) compared to primary infections (31.1%) (P: 0.02) and was also influenced by the result in the confirmatory dengue diagnostic test, ranging from 39.7% for samples of cases confirmed by IgM-ELISA seroconversion between paired samples to 90.4% for samples of cases confirmed by a positive NS1-ELISA. The RDT specificity was 94.4% for non-dengue febrile patients, 87.7% for the community healthy controls, and 95.9% for the blood donors. Conclusions/Significance The SD BIOLINE Dengue Duo RDT showed good specificities, but low sensitivity, suggesting that it may be more useful to rule in than to rule out a dengue diagnosis in dengue endemic regions.
Fil: Kikuti, Mariana. Fundación Oswaldo Cruz; Brasil. Universidade Federal da Bahia; Brasil
Fil: Cruz, Jaqueline S.. Fundación Oswaldo Cruz; Brasil
Fil: Rodrigues, Moreno S.. Fundación Oswaldo Cruz; Brasil
Fil: Tavares, Aline S.. Fundación Oswaldo Cruz; Brasil
Fil: Paploski, Igor A. D.. Universidade Federal da Bahia; Brasil. University of Minnesota; Estados Unidos
Fil: Silva, Monaise M. O.. Fundación Oswaldo Cruz; Brasil
Fil: Santana, Perla M.. Fundación Oswaldo Cruz; Brasil
Fil: Tauro, Laura Beatriz. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Nordeste. Instituto de Biología Subtropical. Instituto de Biología Subtropical - Nodo Puerto Iguazú | Universidad Nacional de Misiones. Instituto de Biología Subtropical. Instituto de Biología Subtropical - Nodo Puerto Iguazú; Argentina. Ministerio de Salud. Instituto Nacional de Medicina Tropical; Argentina
Fil: Silva, Greice A. O. F.. Fundación Oswaldo Cruz; Brasil
Fil: Campos, Gúbio S.. Universidade Federal da Bahia; Brasil
Fil: Araújo, Josélio M. G.. Universidade Federal do Rio Grande do Norte; Brasil
Fil: Kitron, Uriel D.. University of Emory; Estados Unidos
Fil: Reis, Mitermayer G.. Fundación Oswaldo Cruz; Brasil. Universidade Federal da Bahia; Brasil. University of Yale; Estados Unidos
Fil: Ribeiro, Guilherme S.. Universidade Federal da Bahia; Brasil. Fundación Oswaldo Cruz; Brasil
description Background Rapid diagnosis tests (RDTs) are easy to carry out, provide fast results, and could potentially guide medical treatment decisions. We investigated the performance of a commercially available RDT, which simultaneously detects the non-structural 1 (NS1) dengue virus (DENV) antigen, and IgM and IgG DENV antibodies, using representative serum samples from individuals in a dengue endemic area in Salvador, Brazil. Methodology/Principal findings We evaluated the accuracy of the SD BIOLINE Dengue Duo RDT (Abbott, Santa Clara, USA; former Alere Inc, Waltham, USA) in a random collection of sera. Samples included acute-phase sera from 246 laboratory-confirmed dengue cases and 108 non-dengue febrile patients enrolled in a surveillance study for dengue detection, 73 healthy controls living in the same surveillance community, and 73 blood donors. RDT accuracy was blindly assessed based on the combined results for the NS1 and the IgM test components. The RDT sensitivity was 46.8% (38.6% for the NS1 component and 13.8% for the IgM component). Sensitivity was greater for samples obtained from patients with secondary DENV infections (49.8%) compared to primary infections (31.1%) (P: 0.02) and was also influenced by the result in the confirmatory dengue diagnostic test, ranging from 39.7% for samples of cases confirmed by IgM-ELISA seroconversion between paired samples to 90.4% for samples of cases confirmed by a positive NS1-ELISA. The RDT specificity was 94.4% for non-dengue febrile patients, 87.7% for the community healthy controls, and 95.9% for the blood donors. Conclusions/Significance The SD BIOLINE Dengue Duo RDT showed good specificities, but low sensitivity, suggesting that it may be more useful to rule in than to rule out a dengue diagnosis in dengue endemic regions.
publishDate 2019
dc.date.none.fl_str_mv 2019-03
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/104375
Kikuti, Mariana; Cruz, Jaqueline S.; Rodrigues, Moreno S.; Tavares, Aline S.; Paploski, Igor A. D.; et al.; Accuracy of the SD BIOLINE Dengue Duo for rapid point-of-care diagnosis of dengue; Public Library of Science; Plos One; 14; 3; 3-2019; 1-15
1932-6203
CONICET Digital
CONICET
url http://hdl.handle.net/11336/104375
identifier_str_mv Kikuti, Mariana; Cruz, Jaqueline S.; Rodrigues, Moreno S.; Tavares, Aline S.; Paploski, Igor A. D.; et al.; Accuracy of the SD BIOLINE Dengue Duo for rapid point-of-care diagnosis of dengue; Public Library of Science; Plos One; 14; 3; 3-2019; 1-15
1932-6203
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/10.1371/journal.pone.0213301
info:eu-repo/semantics/altIdentifier/url/https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0213301
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Public Library of Science
publisher.none.fl_str_mv Public Library of Science
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1842269157042683904
score 13.13397