The Mach-Zehnder interferometer: Examination of a volume by non-classical localization plane shifting
- Autores
- Simon, Juan Miguel; Comastri, Silvia Ana Elva; Echarri, Rodolfo Manuel
- Año de publicación
- 2001
- Idioma
- inglés
- Tipo de recurso
- artículo
- Estado
- versión publicada
- Descripción
- The Mach-Zehnder interferometer can be used as is customary in optical testing but, to examine different layers of a volume, the procedure of either readjusting the interferometer or displacing the specimen can be avoided, employing an incoherent periodic source. In this case, leaving the specimen in a fixed position and without readjusting the interferometer, the different layers can be analysed, shifting a non-classical localization plane by a change in the source period. In this paper experimental interferograms, obtained by varying this period to map the disturbances present on either one or both faces of a phase object, are shown.
Fil: Simon, Juan Miguel. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física. Laboratorio de Óptica; Argentina
Fil: Comastri, Silvia Ana Elva. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria; Argentina. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física. Laboratorio de Óptica; Argentina
Fil: Echarri, Rodolfo Manuel. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria; Argentina. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física. Laboratorio de Óptica; Argentina - Materia
-
Interferometry
Transparent Media Exploration - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
.jpg)
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/71940
Ver los metadatos del registro completo
| id |
CONICETDig_e4031edca77298b60afc4400c5690b1f |
|---|---|
| oai_identifier_str |
oai:ri.conicet.gov.ar:11336/71940 |
| network_acronym_str |
CONICETDig |
| repository_id_str |
3498 |
| network_name_str |
CONICET Digital (CONICET) |
| spelling |
The Mach-Zehnder interferometer: Examination of a volume by non-classical localization plane shiftingSimon, Juan MiguelComastri, Silvia Ana ElvaEcharri, Rodolfo ManuelInterferometryTransparent Media Explorationhttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1The Mach-Zehnder interferometer can be used as is customary in optical testing but, to examine different layers of a volume, the procedure of either readjusting the interferometer or displacing the specimen can be avoided, employing an incoherent periodic source. In this case, leaving the specimen in a fixed position and without readjusting the interferometer, the different layers can be analysed, shifting a non-classical localization plane by a change in the source period. In this paper experimental interferograms, obtained by varying this period to map the disturbances present on either one or both faces of a phase object, are shown.Fil: Simon, Juan Miguel. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física. Laboratorio de Óptica; ArgentinaFil: Comastri, Silvia Ana Elva. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria; Argentina. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física. Laboratorio de Óptica; ArgentinaFil: Echarri, Rodolfo Manuel. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria; Argentina. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física. Laboratorio de Óptica; ArgentinaIOP Publishing2001-07info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/71940Simon, Juan Miguel; Comastri, Silvia Ana Elva; Echarri, Rodolfo Manuel; The Mach-Zehnder interferometer: Examination of a volume by non-classical localization plane shifting; IOP Publishing; Journal of Optics. A, Pure and Applied Optics (print); 3; 4; 7-2001; 242-2491464-4258CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://iopscience.iop.org/article/10.1088/1464-4258/3/4/303info:eu-repo/semantics/altIdentifier/doi/10.1088/1464-4258/3/4/303info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-10-22T12:17:57Zoai:ri.conicet.gov.ar:11336/71940instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-10-22 12:17:58.215CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
| dc.title.none.fl_str_mv |
The Mach-Zehnder interferometer: Examination of a volume by non-classical localization plane shifting |
| title |
The Mach-Zehnder interferometer: Examination of a volume by non-classical localization plane shifting |
| spellingShingle |
The Mach-Zehnder interferometer: Examination of a volume by non-classical localization plane shifting Simon, Juan Miguel Interferometry Transparent Media Exploration |
| title_short |
The Mach-Zehnder interferometer: Examination of a volume by non-classical localization plane shifting |
| title_full |
The Mach-Zehnder interferometer: Examination of a volume by non-classical localization plane shifting |
| title_fullStr |
The Mach-Zehnder interferometer: Examination of a volume by non-classical localization plane shifting |
| title_full_unstemmed |
The Mach-Zehnder interferometer: Examination of a volume by non-classical localization plane shifting |
| title_sort |
The Mach-Zehnder interferometer: Examination of a volume by non-classical localization plane shifting |
| dc.creator.none.fl_str_mv |
Simon, Juan Miguel Comastri, Silvia Ana Elva Echarri, Rodolfo Manuel |
| author |
Simon, Juan Miguel |
| author_facet |
Simon, Juan Miguel Comastri, Silvia Ana Elva Echarri, Rodolfo Manuel |
| author_role |
author |
| author2 |
Comastri, Silvia Ana Elva Echarri, Rodolfo Manuel |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
Interferometry Transparent Media Exploration |
| topic |
Interferometry Transparent Media Exploration |
| purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.3 https://purl.org/becyt/ford/1 |
| dc.description.none.fl_txt_mv |
The Mach-Zehnder interferometer can be used as is customary in optical testing but, to examine different layers of a volume, the procedure of either readjusting the interferometer or displacing the specimen can be avoided, employing an incoherent periodic source. In this case, leaving the specimen in a fixed position and without readjusting the interferometer, the different layers can be analysed, shifting a non-classical localization plane by a change in the source period. In this paper experimental interferograms, obtained by varying this period to map the disturbances present on either one or both faces of a phase object, are shown. Fil: Simon, Juan Miguel. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física. Laboratorio de Óptica; Argentina Fil: Comastri, Silvia Ana Elva. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria; Argentina. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física. Laboratorio de Óptica; Argentina Fil: Echarri, Rodolfo Manuel. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Ciudad Universitaria; Argentina. Universidad de Buenos Aires. Facultad de Ciencias Exactas y Naturales. Departamento de Física. Laboratorio de Óptica; Argentina |
| description |
The Mach-Zehnder interferometer can be used as is customary in optical testing but, to examine different layers of a volume, the procedure of either readjusting the interferometer or displacing the specimen can be avoided, employing an incoherent periodic source. In this case, leaving the specimen in a fixed position and without readjusting the interferometer, the different layers can be analysed, shifting a non-classical localization plane by a change in the source period. In this paper experimental interferograms, obtained by varying this period to map the disturbances present on either one or both faces of a phase object, are shown. |
| publishDate |
2001 |
| dc.date.none.fl_str_mv |
2001-07 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/71940 Simon, Juan Miguel; Comastri, Silvia Ana Elva; Echarri, Rodolfo Manuel; The Mach-Zehnder interferometer: Examination of a volume by non-classical localization plane shifting; IOP Publishing; Journal of Optics. A, Pure and Applied Optics (print); 3; 4; 7-2001; 242-249 1464-4258 CONICET Digital CONICET |
| url |
http://hdl.handle.net/11336/71940 |
| identifier_str_mv |
Simon, Juan Miguel; Comastri, Silvia Ana Elva; Echarri, Rodolfo Manuel; The Mach-Zehnder interferometer: Examination of a volume by non-classical localization plane shifting; IOP Publishing; Journal of Optics. A, Pure and Applied Optics (print); 3; 4; 7-2001; 242-249 1464-4258 CONICET Digital CONICET |
| dc.language.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/https://iopscience.iop.org/article/10.1088/1464-4258/3/4/303 info:eu-repo/semantics/altIdentifier/doi/10.1088/1464-4258/3/4/303 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
| dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
IOP Publishing |
| publisher.none.fl_str_mv |
IOP Publishing |
| dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
| reponame_str |
CONICET Digital (CONICET) |
| collection |
CONICET Digital (CONICET) |
| instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
| repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
| _version_ |
1846782607572860928 |
| score |
12.982451 |