TiO2 nanotubes for room temperature toluene sensor

Autores
Perillo, Patricia Maria; Rodriguez, Daniel Fabian; Boggio, Norberto Gabriel
Año de publicación
2014
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
TiO2 nanotubes were used to prepare gas sensor and the gas sensing properties towards toluene were analyzed. Titania nanotube arrays were fabricated via electrochemical anodization method in glycerol electrolytes containing NH4F. The sensor fabricated from these nanotubes exhibits a good response to toluene at room temperature with good sensitivity. The toluene sensing properties were tested from 20 to 150 ppm concentrations.
Fil: Perillo, Patricia Maria. Comisión Nacional de Energía Atómica. Gerencia de Área de Investigación y Aplicaciones no Nucleares. Gerencia de Desarrollo Tecnológico y Proyectos Especiales. Departamento de Micro y Nanotecnología; Argentina
Fil: Rodriguez, Daniel Fabian. Comisión Nacional de Energía Atómica. Gerencia de Área de Investigación y Aplicaciones no Nucleares. Gerencia de Desarrollo Tecnológico y Proyectos Especiales. Departamento de Micro y Nanotecnología; Argentina
Fil: Boggio, Norberto Gabriel. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Investigación y Aplicaciones no Nucleares. Gerencia de Desarrollo Tecnológico y Proyectos Especiales. Departamento de Micro y Nanotecnología; Argentina
Materia
TiO2
Nanotubes
Toluene
Gas Sensing
Room Temperature
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/36531

id CONICETDig_dd6ee06f3c277b062681d56695a96752
oai_identifier_str oai:ri.conicet.gov.ar:11336/36531
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling TiO2 nanotubes for room temperature toluene sensorPerillo, Patricia MariaRodriguez, Daniel FabianBoggio, Norberto GabrielTiO2NanotubesTolueneGas SensingRoom Temperaturehttps://purl.org/becyt/ford/2.10https://purl.org/becyt/ford/2TiO2 nanotubes were used to prepare gas sensor and the gas sensing properties towards toluene were analyzed. Titania nanotube arrays were fabricated via electrochemical anodization method in glycerol electrolytes containing NH4F. The sensor fabricated from these nanotubes exhibits a good response to toluene at room temperature with good sensitivity. The toluene sensing properties were tested from 20 to 150 ppm concentrations.Fil: Perillo, Patricia Maria. Comisión Nacional de Energía Atómica. Gerencia de Área de Investigación y Aplicaciones no Nucleares. Gerencia de Desarrollo Tecnológico y Proyectos Especiales. Departamento de Micro y Nanotecnología; ArgentinaFil: Rodriguez, Daniel Fabian. Comisión Nacional de Energía Atómica. Gerencia de Área de Investigación y Aplicaciones no Nucleares. Gerencia de Desarrollo Tecnológico y Proyectos Especiales. Departamento de Micro y Nanotecnología; ArgentinaFil: Boggio, Norberto Gabriel. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Investigación y Aplicaciones no Nucleares. Gerencia de Desarrollo Tecnológico y Proyectos Especiales. Departamento de Micro y Nanotecnología; ArgentinaOALib2014-10info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/36531Perillo, Patricia Maria; Rodriguez, Daniel Fabian; Boggio, Norberto Gabriel; TiO2 nanotubes for room temperature toluene sensor; OALib; OALib; 1; 7; 10-2014; 1-72333-9721CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/doi/10.4236/oalib.1101040info:eu-repo/semantics/altIdentifier/url/http://www.scirp.org/JOURNAL/PaperInformation.aspx?PaperID=64590info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:43:29Zoai:ri.conicet.gov.ar:11336/36531instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:43:29.897CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv TiO2 nanotubes for room temperature toluene sensor
title TiO2 nanotubes for room temperature toluene sensor
spellingShingle TiO2 nanotubes for room temperature toluene sensor
Perillo, Patricia Maria
TiO2
Nanotubes
Toluene
Gas Sensing
Room Temperature
title_short TiO2 nanotubes for room temperature toluene sensor
title_full TiO2 nanotubes for room temperature toluene sensor
title_fullStr TiO2 nanotubes for room temperature toluene sensor
title_full_unstemmed TiO2 nanotubes for room temperature toluene sensor
title_sort TiO2 nanotubes for room temperature toluene sensor
dc.creator.none.fl_str_mv Perillo, Patricia Maria
Rodriguez, Daniel Fabian
Boggio, Norberto Gabriel
author Perillo, Patricia Maria
author_facet Perillo, Patricia Maria
Rodriguez, Daniel Fabian
Boggio, Norberto Gabriel
author_role author
author2 Rodriguez, Daniel Fabian
Boggio, Norberto Gabriel
author2_role author
author
dc.subject.none.fl_str_mv TiO2
Nanotubes
Toluene
Gas Sensing
Room Temperature
topic TiO2
Nanotubes
Toluene
Gas Sensing
Room Temperature
purl_subject.fl_str_mv https://purl.org/becyt/ford/2.10
https://purl.org/becyt/ford/2
dc.description.none.fl_txt_mv TiO2 nanotubes were used to prepare gas sensor and the gas sensing properties towards toluene were analyzed. Titania nanotube arrays were fabricated via electrochemical anodization method in glycerol electrolytes containing NH4F. The sensor fabricated from these nanotubes exhibits a good response to toluene at room temperature with good sensitivity. The toluene sensing properties were tested from 20 to 150 ppm concentrations.
Fil: Perillo, Patricia Maria. Comisión Nacional de Energía Atómica. Gerencia de Área de Investigación y Aplicaciones no Nucleares. Gerencia de Desarrollo Tecnológico y Proyectos Especiales. Departamento de Micro y Nanotecnología; Argentina
Fil: Rodriguez, Daniel Fabian. Comisión Nacional de Energía Atómica. Gerencia de Área de Investigación y Aplicaciones no Nucleares. Gerencia de Desarrollo Tecnológico y Proyectos Especiales. Departamento de Micro y Nanotecnología; Argentina
Fil: Boggio, Norberto Gabriel. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Comisión Nacional de Energía Atómica. Gerencia de Área de Investigación y Aplicaciones no Nucleares. Gerencia de Desarrollo Tecnológico y Proyectos Especiales. Departamento de Micro y Nanotecnología; Argentina
description TiO2 nanotubes were used to prepare gas sensor and the gas sensing properties towards toluene were analyzed. Titania nanotube arrays were fabricated via electrochemical anodization method in glycerol electrolytes containing NH4F. The sensor fabricated from these nanotubes exhibits a good response to toluene at room temperature with good sensitivity. The toluene sensing properties were tested from 20 to 150 ppm concentrations.
publishDate 2014
dc.date.none.fl_str_mv 2014-10
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/36531
Perillo, Patricia Maria; Rodriguez, Daniel Fabian; Boggio, Norberto Gabriel; TiO2 nanotubes for room temperature toluene sensor; OALib; OALib; 1; 7; 10-2014; 1-7
2333-9721
CONICET Digital
CONICET
url http://hdl.handle.net/11336/36531
identifier_str_mv Perillo, Patricia Maria; Rodriguez, Daniel Fabian; Boggio, Norberto Gabriel; TiO2 nanotubes for room temperature toluene sensor; OALib; OALib; 1; 7; 10-2014; 1-7
2333-9721
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/10.4236/oalib.1101040
info:eu-repo/semantics/altIdentifier/url/http://www.scirp.org/JOURNAL/PaperInformation.aspx?PaperID=64590
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv OALib
publisher.none.fl_str_mv OALib
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1842268605791600640
score 13.13397