Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubes

Autores
Ju, J.; Svensson, K.; Döpp, A.; Ferrari, Hugo Emilio; Cassou, K.; Neveu, O.; Genoud, G.; Wojda, F.; Burza, M.; Persson, A.; Lundh, O.; Cros, B.
Año de publicación
2012
Idioma
inglés
Tipo de recurso
artículo
Estado
versión publicada
Descripción
Electrons accelerated in the nonlinear regime in a laser wakefield accelerator experience transverse oscillationsinside the plasma cavity, giving rise to ultra-short pulsed X-rays, also called betatron radiation. We showthat the fluence of X-ray can be enhanced by more than one order of magnitude when the laser is guided by a10 mm long capillary tube instead of interacting with a 2 mm gas jet. X-rays with a synchrotron-like spectrumand associated critical energy ∼ 5 keV, with a peak brightness of ∼ 1 × 1021 ph/s/mm2 /mrad2 /0.1%BW,were achieved by employing 16 TW laser pulses.
Fil: Ju, J.. No especifíca;
Fil: Svensson, K.. Lund University; Suecia
Fil: Döpp, A.. No especifíca;
Fil: Ferrari, Hugo Emilio. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Cassou, K.. No especifíca;
Fil: Neveu, O.. No especifíca;
Fil: Genoud, G.. No especifíca;
Fil: Wojda, F.. Lund University; Suecia
Fil: Burza, M.. Lund University; Suecia
Fil: Persson, A.. Lund University; Suecia
Fil: Lundh, O.. Lund University; Suecia
Fil: Cros, B.. Lund University; Suecia
Materia
LWFA
ACELERATORS
COMPACT
Xradiation
Nivel de accesibilidad
acceso abierto
Condiciones de uso
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
Repositorio
CONICET Digital (CONICET)
Institución
Consejo Nacional de Investigaciones Científicas y Técnicas
OAI Identificador
oai:ri.conicet.gov.ar:11336/197174

id CONICETDig_d919b6f8e2ae8e7a6f1c73ccc0e23c0c
oai_identifier_str oai:ri.conicet.gov.ar:11336/197174
network_acronym_str CONICETDig
repository_id_str 3498
network_name_str CONICET Digital (CONICET)
spelling Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubesJu, J.Svensson, K.Döpp, A.Ferrari, Hugo EmilioCassou, K.Neveu, O.Genoud, G.Wojda, F.Burza, M.Persson, A.Lundh, O.Cros, B.LWFAACELERATORSCOMPACTXradiationhttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1Electrons accelerated in the nonlinear regime in a laser wakefield accelerator experience transverse oscillationsinside the plasma cavity, giving rise to ultra-short pulsed X-rays, also called betatron radiation. We showthat the fluence of X-ray can be enhanced by more than one order of magnitude when the laser is guided by a10 mm long capillary tube instead of interacting with a 2 mm gas jet. X-rays with a synchrotron-like spectrumand associated critical energy ∼ 5 keV, with a peak brightness of ∼ 1 × 1021 ph/s/mm2 /mrad2 /0.1%BW,were achieved by employing 16 TW laser pulses.Fil: Ju, J.. No especifíca;Fil: Svensson, K.. Lund University; SueciaFil: Döpp, A.. No especifíca;Fil: Ferrari, Hugo Emilio. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Cassou, K.. No especifíca;Fil: Neveu, O.. No especifíca;Fil: Genoud, G.. No especifíca;Fil: Wojda, F.. Lund University; SueciaFil: Burza, M.. Lund University; SueciaFil: Persson, A.. Lund University; SueciaFil: Lundh, O.. Lund University; SueciaFil: Cros, B.. Lund University; SueciaAmerican Institute of Physics2012-05info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/197174Ju, J.; Svensson, K.; Döpp, A.; Ferrari, Hugo Emilio; Cassou, K.; et al.; Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubes; American Institute of Physics; Applied Physics Letters; 100; 19; 5-2012; 191106-1911080003-6951CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/https://pubs.aip.org/aip/apl/article/100/19/191106/891808/Enhancement-of-x-rays-generated-by-a-guided-laserinfo:eu-repo/semantics/altIdentifier/doi/10.1063/1.4712594info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-29T09:36:35Zoai:ri.conicet.gov.ar:11336/197174instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-29 09:36:35.301CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse
dc.title.none.fl_str_mv Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubes
title Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubes
spellingShingle Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubes
Ju, J.
LWFA
ACELERATORS
COMPACT
Xradiation
title_short Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubes
title_full Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubes
title_fullStr Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubes
title_full_unstemmed Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubes
title_sort Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubes
dc.creator.none.fl_str_mv Ju, J.
Svensson, K.
Döpp, A.
Ferrari, Hugo Emilio
Cassou, K.
Neveu, O.
Genoud, G.
Wojda, F.
Burza, M.
Persson, A.
Lundh, O.
Cros, B.
author Ju, J.
author_facet Ju, J.
Svensson, K.
Döpp, A.
Ferrari, Hugo Emilio
Cassou, K.
Neveu, O.
Genoud, G.
Wojda, F.
Burza, M.
Persson, A.
Lundh, O.
Cros, B.
author_role author
author2 Svensson, K.
Döpp, A.
Ferrari, Hugo Emilio
Cassou, K.
Neveu, O.
Genoud, G.
Wojda, F.
Burza, M.
Persson, A.
Lundh, O.
Cros, B.
author2_role author
author
author
author
author
author
author
author
author
author
author
dc.subject.none.fl_str_mv LWFA
ACELERATORS
COMPACT
Xradiation
topic LWFA
ACELERATORS
COMPACT
Xradiation
purl_subject.fl_str_mv https://purl.org/becyt/ford/1.3
https://purl.org/becyt/ford/1
dc.description.none.fl_txt_mv Electrons accelerated in the nonlinear regime in a laser wakefield accelerator experience transverse oscillationsinside the plasma cavity, giving rise to ultra-short pulsed X-rays, also called betatron radiation. We showthat the fluence of X-ray can be enhanced by more than one order of magnitude when the laser is guided by a10 mm long capillary tube instead of interacting with a 2 mm gas jet. X-rays with a synchrotron-like spectrumand associated critical energy ∼ 5 keV, with a peak brightness of ∼ 1 × 1021 ph/s/mm2 /mrad2 /0.1%BW,were achieved by employing 16 TW laser pulses.
Fil: Ju, J.. No especifíca;
Fil: Svensson, K.. Lund University; Suecia
Fil: Döpp, A.. No especifíca;
Fil: Ferrari, Hugo Emilio. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
Fil: Cassou, K.. No especifíca;
Fil: Neveu, O.. No especifíca;
Fil: Genoud, G.. No especifíca;
Fil: Wojda, F.. Lund University; Suecia
Fil: Burza, M.. Lund University; Suecia
Fil: Persson, A.. Lund University; Suecia
Fil: Lundh, O.. Lund University; Suecia
Fil: Cros, B.. Lund University; Suecia
description Electrons accelerated in the nonlinear regime in a laser wakefield accelerator experience transverse oscillationsinside the plasma cavity, giving rise to ultra-short pulsed X-rays, also called betatron radiation. We showthat the fluence of X-ray can be enhanced by more than one order of magnitude when the laser is guided by a10 mm long capillary tube instead of interacting with a 2 mm gas jet. X-rays with a synchrotron-like spectrumand associated critical energy ∼ 5 keV, with a peak brightness of ∼ 1 × 1021 ph/s/mm2 /mrad2 /0.1%BW,were achieved by employing 16 TW laser pulses.
publishDate 2012
dc.date.none.fl_str_mv 2012-05
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
http://purl.org/coar/resource_type/c_6501
info:ar-repo/semantics/articulo
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11336/197174
Ju, J.; Svensson, K.; Döpp, A.; Ferrari, Hugo Emilio; Cassou, K.; et al.; Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubes; American Institute of Physics; Applied Physics Letters; 100; 19; 5-2012; 191106-191108
0003-6951
CONICET Digital
CONICET
url http://hdl.handle.net/11336/197174
identifier_str_mv Ju, J.; Svensson, K.; Döpp, A.; Ferrari, Hugo Emilio; Cassou, K.; et al.; Enhancement of x-rays generated by a guided laser wakefield accelerator inside capillary tubes; American Institute of Physics; Applied Physics Letters; 100; 19; 5-2012; 191106-191108
0003-6951
CONICET Digital
CONICET
dc.language.none.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/url/https://pubs.aip.org/aip/apl/article/100/19/191106/891808/Enhancement-of-x-rays-generated-by-a-guided-laser
info:eu-repo/semantics/altIdentifier/doi/10.1063/1.4712594
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv American Institute of Physics
publisher.none.fl_str_mv American Institute of Physics
dc.source.none.fl_str_mv reponame:CONICET Digital (CONICET)
instname:Consejo Nacional de Investigaciones Científicas y Técnicas
reponame_str CONICET Digital (CONICET)
collection CONICET Digital (CONICET)
instname_str Consejo Nacional de Investigaciones Científicas y Técnicas
repository.name.fl_str_mv CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas
repository.mail.fl_str_mv dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar
_version_ 1844613148312600576
score 13.070432