- Lasers are the pillars of modern optics and sensing. Microlasers based on whispering-gallery modes (WGMs) are miniature in size and have excellent lasing characteristics suitable for biosensing. WGM lasers have been used for label-free detection of single virus particles, detection of molecular electrostatic changes at biointerfaces, and barcode-type live-cell tagging and tracking. The most recent advances in biosensing with WGM microlasers are described in this review. We cover the basic concepts of WGM resonators, the integration of gain media into various active WGM sensors and devices, and the cutting-edge advances in photonic devices for micro- and nanoprobing of biological samples that can be integrated with WGM lasers.
Fil: Toropov, Nikita. University of Exeter; Reino Unido
Fil: Cabello, Gema. University of Exeter; Reino Unido
Fil: Serrano, Mariana Paula. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina
Fil: Gutha, Rithvik R.. University of Exeter; Reino Unido
Fil: Rafti, Matias. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina
Fil: Vollmer, Frank. University of Exeter; Reino Unido - Materia
-
Lasers
BioLasers
WGM
Ring resonators - Nivel de accesibilidad
- acceso abierto
- Condiciones de uso
- https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
- Repositorio
- Institución
- Consejo Nacional de Investigaciones Científicas y Técnicas
- OAI Identificador
- oai:ri.conicet.gov.ar:11336/172199
Ver los metadatos del registro completo
id |
CONICETDig_d6886ca4eb33163de56c4bf566b0c2f6 |
---|---|
oai_identifier_str |
oai:ri.conicet.gov.ar:11336/172199 |
network_acronym_str |
CONICETDig |
repository_id_str |
3498 |
network_name_str |
CONICET Digital (CONICET) |
spelling |
Review of biosensing with whispering-gallery mode lasersToropov, NikitaCabello, GemaSerrano, Mariana PaulaGutha, Rithvik R.Rafti, MatiasVollmer, FrankLasersBioLasersWGMRing resonatorshttps://purl.org/becyt/ford/1.3https://purl.org/becyt/ford/1Lasers are the pillars of modern optics and sensing. Microlasers based on whispering-gallery modes (WGMs) are miniature in size and have excellent lasing characteristics suitable for biosensing. WGM lasers have been used for label-free detection of single virus particles, detection of molecular electrostatic changes at biointerfaces, and barcode-type live-cell tagging and tracking. The most recent advances in biosensing with WGM microlasers are described in this review. We cover the basic concepts of WGM resonators, the integration of gain media into various active WGM sensors and devices, and the cutting-edge advances in photonic devices for micro- and nanoprobing of biological samples that can be integrated with WGM lasers.Fil: Toropov, Nikita. University of Exeter; Reino UnidoFil: Cabello, Gema. University of Exeter; Reino UnidoFil: Serrano, Mariana Paula. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; ArgentinaFil: Gutha, Rithvik R.. University of Exeter; Reino UnidoFil: Rafti, Matias. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; ArgentinaFil: Vollmer, Frank. University of Exeter; Reino UnidoSpringer Nature2021-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501info:ar-repo/semantics/articuloapplication/pdfapplication/pdfapplication/pdfhttp://hdl.handle.net/11336/172199Toropov, Nikita; Cabello, Gema; Serrano, Mariana Paula; Gutha, Rithvik R.; Rafti, Matias; et al.; Review of biosensing with whispering-gallery mode lasers; Springer Nature; Light: Science and Applications; 10; 1; 12-2021; 1-192047-7538CONICET DigitalCONICETenginfo:eu-repo/semantics/altIdentifier/url/http://www.nature.com/articles/s41377-021-00471-3info:eu-repo/semantics/altIdentifier/doi/10.1038/s41377-021-00471-3info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/reponame:CONICET Digital (CONICET)instname:Consejo Nacional de Investigaciones Científicas y Técnicas2025-09-03T09:46:23Zoai:ri.conicet.gov.ar:11336/172199instacron:CONICETInstitucionalhttp://ri.conicet.gov.ar/Organismo científico-tecnológicoNo correspondehttp://ri.conicet.gov.ar/oai/requestdasensio@conicet.gov.ar; lcarlino@conicet.gov.arArgentinaNo correspondeNo correspondeNo correspondeopendoar:34982025-09-03 09:46:24.088CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicasfalse |
dc.title.none.fl_str_mv |
Review of biosensing with whispering-gallery mode lasers |
title |
Review of biosensing with whispering-gallery mode lasers |
spellingShingle |
Review of biosensing with whispering-gallery mode lasers Toropov, Nikita Lasers BioLasers WGM Ring resonators |
title_short |
Review of biosensing with whispering-gallery mode lasers |
title_full |
Review of biosensing with whispering-gallery mode lasers |
title_fullStr |
Review of biosensing with whispering-gallery mode lasers |
title_full_unstemmed |
Review of biosensing with whispering-gallery mode lasers |
title_sort |
Review of biosensing with whispering-gallery mode lasers |
dc.creator.none.fl_str_mv |
Toropov, Nikita Cabello, Gema Serrano, Mariana Paula Gutha, Rithvik R. Rafti, Matias Vollmer, Frank |
author |
Toropov, Nikita |
author_facet |
Toropov, Nikita Cabello, Gema Serrano, Mariana Paula Gutha, Rithvik R. Rafti, Matias Vollmer, Frank |
author_role |
author |
author2 |
Cabello, Gema Serrano, Mariana Paula Gutha, Rithvik R. Rafti, Matias Vollmer, Frank |
author2_role |
author author author author author |
dc.subject.none.fl_str_mv |
Lasers BioLasers WGM Ring resonators |
topic |
Lasers BioLasers WGM Ring resonators |
purl_subject.fl_str_mv |
https://purl.org/becyt/ford/1.3 https://purl.org/becyt/ford/1 |
dc.description.none.fl_txt_mv |
Lasers are the pillars of modern optics and sensing. Microlasers based on whispering-gallery modes (WGMs) are miniature in size and have excellent lasing characteristics suitable for biosensing. WGM lasers have been used for label-free detection of single virus particles, detection of molecular electrostatic changes at biointerfaces, and barcode-type live-cell tagging and tracking. The most recent advances in biosensing with WGM microlasers are described in this review. We cover the basic concepts of WGM resonators, the integration of gain media into various active WGM sensors and devices, and the cutting-edge advances in photonic devices for micro- and nanoprobing of biological samples that can be integrated with WGM lasers. Fil: Toropov, Nikita. University of Exeter; Reino Unido Fil: Cabello, Gema. University of Exeter; Reino Unido Fil: Serrano, Mariana Paula. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina Fil: Gutha, Rithvik R.. University of Exeter; Reino Unido Fil: Rafti, Matias. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas; Argentina Fil: Vollmer, Frank. University of Exeter; Reino Unido |
description |
Lasers are the pillars of modern optics and sensing. Microlasers based on whispering-gallery modes (WGMs) are miniature in size and have excellent lasing characteristics suitable for biosensing. WGM lasers have been used for label-free detection of single virus particles, detection of molecular electrostatic changes at biointerfaces, and barcode-type live-cell tagging and tracking. The most recent advances in biosensing with WGM microlasers are described in this review. We cover the basic concepts of WGM resonators, the integration of gain media into various active WGM sensors and devices, and the cutting-edge advances in photonic devices for micro- and nanoprobing of biological samples that can be integrated with WGM lasers. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-12 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion http://purl.org/coar/resource_type/c_6501 info:ar-repo/semantics/articulo |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11336/172199 Toropov, Nikita; Cabello, Gema; Serrano, Mariana Paula; Gutha, Rithvik R.; Rafti, Matias; et al.; Review of biosensing with whispering-gallery mode lasers; Springer Nature; Light: Science and Applications; 10; 1; 12-2021; 1-19 2047-7538 CONICET Digital CONICET |
url |
http://hdl.handle.net/11336/172199 |
identifier_str_mv |
Toropov, Nikita; Cabello, Gema; Serrano, Mariana Paula; Gutha, Rithvik R.; Rafti, Matias; et al.; Review of biosensing with whispering-gallery mode lasers; Springer Nature; Light: Science and Applications; 10; 1; 12-2021; 1-19 2047-7538 CONICET Digital CONICET |
dc.language.none.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/url/http://www.nature.com/articles/s41377-021-00471-3 info:eu-repo/semantics/altIdentifier/doi/10.1038/s41377-021-00471-3 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ |
dc.format.none.fl_str_mv |
application/pdf application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Springer Nature |
publisher.none.fl_str_mv |
Springer Nature |
dc.source.none.fl_str_mv |
reponame:CONICET Digital (CONICET) instname:Consejo Nacional de Investigaciones Científicas y Técnicas |
reponame_str |
CONICET Digital (CONICET) |
collection |
CONICET Digital (CONICET) |
instname_str |
Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.name.fl_str_mv |
CONICET Digital (CONICET) - Consejo Nacional de Investigaciones Científicas y Técnicas |
repository.mail.fl_str_mv |
dasensio@conicet.gov.ar; lcarlino@conicet.gov.ar |
_version_ |
1842268791472390144 |
score |
13.13397 |